Anritsu MA2421A

| Atributo | Valor |
|---|---|
| Rango de Frecuencia | 10 MHz – 18 GHz |
| Rango de Potencia | -70 dBm a +20 dBm |
| Tipo de Detector | Detector de potencia de diodo |
| Impedancia | 50 Ohmios |
| Conector de Entrada | APC-3.5 (macho) |
| Tiempo de Respuesta | Inferior a 1 µs (modo rápido) |
| Incertidumbre de Calibración | ±0,9 dB (máximo a 18 GHz) |
| Coeficiente de Reflexión (SWR) | Inferior a 1,35:1 (hasta 18 GHz) |
| Temperatura de Operación | 0 °C a +55 °C |
| Compatibilidad | Compatible con medidores de potencia Anritsu serie ML2400 y ML4803 |
Anritsu MA2421A Options:
- ML2490A - 06 - Rear Mount Input A
- ML2490A - 07 - Rear Input A and Reference
- ML2490A - 08 - Rear Mount Inputs A, B and Reference
- ML2490A - 09 - Rear Mount Inputs A and B
- ML2490A - 33 - Extra Operating Manual
- ML2490A - 34 - Extra Programming Manual
- ML2490A - 37 - Electronic Manuals (deletes paper version from shipment)
- ML2490A - 98 - Calibration to Z540, ISO Guide 25
- ML2490A - 99 - Premium Calibration
- ML2480A - 06 - Rear Mount Input A
- ML2480A - 07 - Rear Input A and Reference
- ML2480A - 08 - Rear Mount Inputs A, B and Reference
- ML2480A - 09 - Rear Mount Inputs A and B
- ML2480A - 15 - Factory Fitted 50MHz and 1GHz Calibrator (required by MA2411B Sensor)
- ML2480A - 15R - Retro Fit Calibrator Kit
- ML2480A - 33 - Extra Operating Manual ML2487/8A
- ML2480A - 34 - Extra Programming Manual ML2487/8A
- ML2480A - 35 - Extra Operating Manual: Japanese
- ML2480A - 36 - Extra Programming Manual: Japanese
- ML2480A - 37 - Electronic Manuals only (deletes paper version from shipment)
- ML2480A - 98 - Calibration to Z540, ISO Guide 25
- ML2480A - 99 - Premium Calibration
- ML2400A - 32A - Maintenance Manual ML2480/90A Series
- ML2400A - 31A - Option 31, Extra Operation/Prog manual ML2480A
- ML2400A - 06 - Rear Mount Input A on ML2437A
- ML2400A - 07 - Rear Input A and Reference on ML2437A
- ML2400A - 08 - Rear Mount Inputs A, B and Reference
- ML2400A - 09 - Rear Mount Inputs A and B on ML2438A
- ML2400A - 11 - NiMH Battery with Desktop Charger
- ML2400A - 11A - NiMH Battery with Desktop Charger (for use in Japan only)
- ML2400A - 22 - 3m Sensor Cable
- ML2400A - 23 - 5m Sensor Cable
- ML2400A - 24 - 10m Sensor Cable
- ML2400A - 25 - 30m Sensor Cable
- ML2400A - 26 - 50m Sensor Cable
- ML2400A - 27 - 100m Sensor Cable
- ML2400A - 30 - Extra Operation Manual ML2437/8A
- ML2400A - 98 - Calibration to Z540, ISO Guide 25
- ML2400A - 99 - Premium Calibration
- ML2400A - 30A - Option 30, Extra Operation/Prog manual (For use in Japan, only)
- ML2400A - 10585-00003 - Maintenance Manual ML2400A Series
- ML2400A - 33 - Extra Operating & Programming Manual ML2437/8A
- MA2499B - MA2499B - Anritsu 4700 & 4600 Series Sensor Adapter
- ML2400A - 01 - Rack Mount, single unit
- ML2400A - 03 - Rack Mount, side by side
- ML2400A - 05 - Front Bail Handle
- ML2400A - 12 - Front Panel Cover
- ML2400A - 20 - Spare 1.5m Sensor Cable
- ML2400A - 21 - 0.3m Sensor Cable
- ML2400A - 28 - RS232 Bootload Cable
- ML2400A - 29 - Bulkhead Adapter
- MA2418A - MA2418A - 50 MHz Reference Oscillator with Power Supply
- MA2419A - MA2419A - Range Calibrator
- MA2497A - MA2497A - Agilent/HP84xxA Series Sensor Adaptor
- MA2421A - 760-209 - Hardside Transit Case
- MA2421A - D41310 - Soft Carry Case with Shoulder Strap
El Anritsu MA2421A es un sensor de potencia térmico basado en el efecto Seebeck que ofrece lecturas precisas de potencia media verdadera de 100 kHz a 18 GHz, desde –30 dBm hasta +20 dBm, con alta linealidad, estabilidad y baja pérdida de retorno mediante calibración dinámica con EEPROM integrado.
Ideal para aplicaciones de RF y microondas, presenta una respuesta rápida de subida/bajada < 4 ms, detección independiente de forma de onda tipo termopar y amplio rango dinámico de 50 dB para un rendimiento fiable en diversos entornos de prueba.
Testwall puede suministrar el Anritsu MA2421A usado, completamente probado. Con soporte experto y entrega global, Testwall garantiza instrumentación de alto rendimiento con una fiabilidad y calidad de servicio incomparables. Póngase en contacto con nosotros directamente si necesita calibración o reparación del Anritsu MA2421A.





