Chroma
Chroma 62024P-40-120
Programmable DC Power Supply, 40V, 120A, 2400W
40 V Tensión de salida máxima
120 A Corriente de salida máxima
2400 W Potencia máxima de salida
180 - 265 VAC, monofásico Tensión de entrada
USB, RS-232, GPIB, Ethernet (LAN) Interfaz de comunicación

| Atributo | Valor |
|---|---|
| Tensión de salida máxima | 40 V |
| Corriente de salida máxima | 120 A |
| Potencia máxima de salida | 2400 W |
| Tensión de entrada | 180 - 265 VAC, monofásico |
| Interfaz de comunicación | USB, RS-232, GPIB, Ethernet (LAN) |
| Resolución de tensión | 10 mV |
| Resolución de corriente | 10 mA |
| Función de simulación de paneles solares | Sí, compatible con simulación fotovoltaica (SAS) |
| Dimensiones (U de rack) | 2U |
| Normativas y certificaciones | CE, UL |
Chroma 62024P-40-120 Options:
- 62024P-40-120 - A620004 - GPIB Interface for Model 62000P Series
- 62024P-40-120 - A620006 - Rack mounting kit for Model 62000P Series (2U model)
- 62024P-40-120 - A620009 - Softpanel for 62000P Series
- 62024P-40-120 - A620023 - Ethernet/LXI Interface for Model 62000P Series
| Model | 62024P-40-120 |
|---|
Chroma 62024P-40-120 POWER SUPPLYThe Chroma 62024P-40-120 Programmable DC Power Supply with its constant power operating envelope can provide high voltage/low cur as well as low voltage/high cur in a single instrument. This efficient design reduces the number of supplies needed in typical ATE and benchtop applications. The Chroma 62024P-40-120 Programmable DC Power Supply also provides precision readback of output cur and voltage and output trigger signals. It provides the ability to create complex DC transients waveforms to test device behavior to spikes, drops, and other voltage deviations and is perfect for automated testing DC-DC converters and similar products.Features and Specifications of the Chroma 62024P-40-120 Programmable DC Power Supply include: Features: Specifications: Wider range of voltage & cur within the power rating of the power supply High-speed Programming Precision V&I Measurements Cur sharing for parallel operation with Master/Slave Control LXI option Constant power operating envelope: High Accuracy cur readback: DC Transients: Output Trigger: VID Control: Instruments include 8 independent programmable TTL signals which can be used for VID control or any general purpose logic controls Soft Panels: Provides higher curs at lower voltages One power supply can do the job of two or three conventional supplies No need for both high cur/low voltage and low cur/high voltage supplies to test a family of converters No need for cur shunts/mux/DMMs to measure the converter's input cur accurately Work benches and test systems are less complex, less costly and can cover a wider range of converters Provides programmable control over voltage and cur rise and falls times Allows complex dc transients to be generated which are not possible with conventional power supplies Supports: Automotive transient testing per ISO16750-2 Shipboard - DO-160 Provides output trigger timing and precision event capturing Ideal for ATE systems desiring to capture Oscilloscope waveforms Advanced Labview graphical control panels Allow for simple and efficient control and data gathering Output Rationgs: Line Regulation: Load Regulation: Voltage Measurement: Cur Measurement: Output Noise (0-20MHz): OVP Adjustment Range: 110% of Vset to 110% of Vmax Slew Rate Range: Programming Response Time (Typical): Efficiency: 0.85 Drift (8 hours): Temperature Coefficient: Transient Response Time: 3mS AC Input Voltage Ranges: 190 to 250 Vac (single phase) Output Voltage: 0~40V Output Cur: 0~120A Output Power: 1200~2400W Voltage: 0.01%+2mV Cur: 0.01%+25mA Voltage: 0.01%+3mV Cur: 0.03%+10mA Range: 8V / 40V Accuracy: 0.05%+0.05%F.S. Range: 24A / 120A Accuracy: 0.1%+0.1%F.S. Voltage Ripple (P-P): 90 mV Voltage Ripple (ms): 10 mV Cur Ripple (ms): 120 mA Voltage (with USB): 0.001V - 5V /ms Cur (with USB): 0.001A - 1A / ms Rise Time (Full & No Load): 8 ms Fall Time: 460 ms(max) Voltage: 0.02% of Vmax Cur: 0.04% of Imax Voltage: 0.02% of Vmax /°C Cur: 0.04% of Imax /°C 10% Step Change: 150 mV Voltage Limit @ Series Mode: 200V
- Wider range of voltage & cur within the power rating of the power supply
- High-speed Programming
- Precision V&I Measurements
- Cur sharing for parallel operation with Master/Slave Control
- LXI option
- Constant power operating envelope:
- Provides higher curs at lower voltages
- One power supply can do the job of two or three conventional supplies
- No need for both high cur/low voltage and low cur/high voltage supplies to test a family of converters
- High Accuracy cur readback:
- No need for cur shunts/mux/DMMs to measure the converter's input cur accurately
- Work benches and test systems are less complex, less costly and can cover a wider range of converters
- DC Transients:
- Provides programmable control over voltage and cur rise and falls times
- Allows complex dc transients to be generated which are not possible with conventional power supplies
- Supports:
- Automotive transient testing per ISO16750-2
- Shipboard - DO-160
- Output Trigger:
- Provides output trigger timing and precision event capturing
- Ideal for ATE systems desiring to capture Oscilloscope waveforms
- VID Control: Instruments include 8 independent programmable TTL signals which can be used for VID control or any general purpose logic controls
- Soft Panels:
- Advanced Labview graphical control panels
- Allow for simple and efficient control and data gathering
- Output Rationgs:
- Output Voltage: 0~40V
- Output Cur: 0~120A
- Output Power: 1200~2400W
- Line Regulation:
- Voltage: 0.01%+2mV
- Cur: 0.01%+25mA
- Load Regulation:
- Voltage: 0.01%+3mV
- Cur: 0.03%+10mA
- Voltage Measurement:
- Range: 8V / 40V
- Accuracy: 0.05%+0.05%F.S.
- Cur Measurement:
- Range: 24A / 120A
- Accuracy: 0.1%+0.1%F.S.
- Output Noise (0-20MHz):
- Voltage Ripple (P-P): 90 mV
- Voltage Ripple (ms): 10 mV
- Cur Ripple (ms): 120 mA
- OVP Adjustment Range: 110% of Vset to 110% of Vmax
- Slew Rate Range:
- Voltage (with USB): 0.001V - 5V /ms
- Cur (with USB): 0.001A - 1A / ms
- Programming Response Time (Typical):
- Rise Time (Full & No Load): 8 ms
- Fall Time: 460 ms(max)
- Efficiency: 0.85
- Drift (8 hours):
- Voltage: 0.02% of Vmax
- Cur: 0.04% of Imax
- Temperature Coefficient:
- Voltage: 0.02% of Vmax /°C
- Cur: 0.04% of Imax /°C
- Transient Response Time: 3mS
- 10% Step Change: 150 mV
- Voltage Limit @ Series Mode: 200V
- AC Input Voltage Ranges: 190 to 250 Vac (single phase)
- Provides higher curs at lower voltages
- One power supply can do the job of two or three conventional supplies
- No need for both high cur/low voltage and low cur/high voltage supplies to test a family of converters
- No need for cur shunts/mux/DMMs to measure the converter's input cur accurately
- Work benches and test systems are less complex, less costly and can cover a wider range of converters
- Provides programmable control over voltage and cur rise and falls times
- Allows complex dc transients to be generated which are not possible with conventional power supplies
- Supports:
- Automotive transient testing per ISO16750-2
- Shipboard - DO-160
- Provides output trigger timing and precision event capturing
- Ideal for ATE systems desiring to capture Oscilloscope waveforms
- Advanced Labview graphical control panels
- Allow for simple and efficient control and data gathering
- Automotive transient testing per ISO16750-2
- Shipboard - DO-160
- Output Voltage: 0~40V
- Output Cur: 0~120A
- Output Power: 1200~2400W
- Voltage: 0.01%+2mV
- Cur: 0.01%+25mA
- Voltage: 0.01%+3mV
- Cur: 0.03%+10mA
- Range: 8V / 40V
- Accuracy: 0.05%+0.05%F.S.
- Range: 24A / 120A
- Accuracy: 0.1%+0.1%F.S.
- Voltage Ripple (P-P): 90 mV
- Voltage Ripple (ms): 10 mV
- Cur Ripple (ms): 120 mA
- Voltage (with USB): 0.001V - 5V /ms
- Cur (with USB): 0.001A - 1A / ms
- Rise Time (Full & No Load): 8 ms
- Fall Time: 460 ms(max)
- Voltage: 0.02% of Vmax
- Cur: 0.04% of Imax
- Voltage: 0.02% of Vmax /°C
- Cur: 0.04% of Imax /°C
- 10% Step Change: 150 mV
- Voltage Limit @ Series Mode: 200V