Chroma

Chroma 63600-5

DC Electronic Load Mainframe
500 V Voltaje máximo de entrada
5 A Corriente máxima
150 W Potencia máxima
1 canal Número de canales
0,02 Ω – 10 kΩ Rango de resistencia dinámica
Solicitar ficha técnica
Atributo Valor
Voltaje máximo de entrada 500 V
Corriente máxima 5 A
Potencia máxima 150 W
Número de canales 1 canal
Rango de resistencia dinámica 0,02 Ω – 10 kΩ
Modos de operación CC, CV, CR, CP
Interfaz de comunicación Compatible con bus de módulo 63600
Resolución de corriente 0,1 mA
Velocidad de respuesta dinámica Alta velocidad con transición programable
Factor de forma Módulo para chasis serie Chroma 63600
Chroma 63600-5 Options:
  • 63600-5 - A636000 - GPIB Interface
  • 63600-5 - A636001 - Ethernet Interface
  • 63600-5 - A636003 - External Signal Board (Test Pin)
  • 63600-5 - A636005 - External Signal Board (BNC)
  • 63600-5 - A632006 - NI USB-6211 Bus-Powered Multifunction DAQ
Formulario de calibración Chroma 63600-5

Formulario de reparación Chroma 63600-5
Maximum file size: 40MB

No Related Posts

Más información
Model63600-5
Chroma 63600-5 5-Slot DC Electronic Load Mainframe 
     Chroma's 63600 series DC electronic loads are excellent for research, development, production, and incoming inspection applications. The state of the art design uses DSP technology to simulate non-linear loads using a unique CZ operation mode allowing realistic loading behavior. The Chroma 63600-5 electronic load mainframe accepts five user-installable DC load modules for easy system configuration. The Chroma 63600-5 mainframe holds five 63610 load modules to offer up to 10 - 100W load input channels with standard front-panel inputs. The maximum power for a single mainframe is 2kW when five 63640-80-80 load modules are paralleled. All modules on the mainframe share a common GPIB address to synchronize and speed up the control of the load modules and read back the operating data.     Chroma's 63600-5 Programmable Electronic Load integrates micro-processing capability into each load module to optimize the speed and control among multiple load modules. All load modules are configured to work independently, though testing can be carried out simultaneously at multiple outputs via remote control to simulate real life application. 100 programmable loading sequences enable the user to simulate various real world conditions. In addition, each module can be operated independently or synchronized so that all modules start operating at the same time while running independent programs. DC load modules operate in constant voltage, cur, resistance, power, or impedance. Real time measurement of voltage and cur are integrated into each DC load module using a 16-bit measurement circuit with three cur ranges, achieving 0.025%+0.01%F.S., 0.05%+0.05%F.S. and 0.1%+0.1%F.S. accuracy for voltage, cur and power measurement respectively. Precise measurements like these are ideal for testing power efficiency and other critical parameters of the UUT's. The precise measurement of Chroma 63600-5 also meets the requirements of ENERGY STAR® and 80 Plus. Compatible Load Modules: For Single Slot and 2-Slot Mainframes, see Chroma 63600-1 and Chroma 63600-2      
Clicky Copyright © 2013-present Magento, Inc. All rights reserved.