Dranetz-BMI POWERXPLORER PX5-400

ProductoPower Quality Analyser, 50/60 and 400 Hz

 

Dranetz-BMI CT-3000

Dranetz-BMI CT-3000

AEMC 8336

AEMC 8336

Obtener cotización
SKU
124527
The Dranetz-BMI PowerXplorer PX5-400 Power Quality Analyser integrates the most advanced feature set available in a power monitoring instrument, with an easy-to-navigate, color graphical user interface. With high-speed sampling and data capture (1 microsecond/channel), this 8-channel workhorse simultaneously captures and characterizes thousands of parameters, using a range of standard and customizable operating modes. The unique measurement capabilities of the PowerXplorer include capture of low-medium-high frequency transients through peak, waveshape, rms duration and adaptive high-speed sampling, as well as power measurements to clearly characterize non-sinusoidal and unbalanced systems.Features and highlights of the Dranetz-BMI PowerXplorer PX5-400 Power Quality Analyser include:
  • Tests at 50/60 and 400Hz
  • Meets MIL Standard 1399 Testing
  • Eight channels, 4 voltage & 4 cur
  • Intuitive color touch screen
  • Light weight – About 4 pounds, 2 kg – with rugged rubber boot
  • AC/DC applications
  • Samples at 256 samples/cycle
  • Independent voltage & cur triggering, cross triggering
  • High-speed sampling and data capture (1 microsecond/channel)
  • Oscilloscope-like high speed transient detection (Dranetz 658-like and BMI-8800 like)
  • Detailed event characterization of RMS variations and transients
  • THD/harmonic spectrum and TID/interharmonics spectrum to the 63rd at 50/60 Hz
  • Captures IEEE 1459 parameters for non-sinusoidal and advanced power systems
  • Remote communications—RS-232, Ethernet or USB
  • Battery or AC mode
  • Built in UPS battery with external charger
  • Expanded memory up to 128 MB
  • Available languages – English, Spanish, French, German, Italian, Swedish, Finnish, Chinese, Japanese, Korean
  • DRAN-VIEW enabled (Windows NT, 98, ME, 2000, XP)
  • Measures flicker according to IEC 61000-4-15
  • Complies with IEEE 1159, IEC 61000-4-30 Class A and EN50160
  • PX5-400 is 400 Hz measurement version
  • PowerXplorer users can select from a multitude of data displays such as phasors, waveforms, meters and harmonic spectrums, as well as recording options that include continuous monitoring or report-by exception, and AC and DC measurements for events lasting from a microsecond to an hour.
  • Measured Parameters:
    • (4) diffeial inputs, 1-600 Vrms, AC/DC, 0.1% rdg + 0.05% FS, 256 samples/cycle, 16 bit ADC
    • (4) inputs with CTs 0.1-6000 Arms CT-dependent, AC/DC, 0.1%rdg + CTs, 256 samples/cycle, 16 bit ADC
    • 1 MHz High Speed Sampling, 14 bit ADC, 1%FS
    • Frequency Range, 10m Hz resolution, 15-20 Hz, 45-65 Hz, or 350-450 Hz
    • Phase Lock Loop - Generator tracking
    • Phase Lock Loop - Standard PQ mode
  • Power Quality Triggers:
    • Cycle-by-cycle analysis
    • 256 samples/cycle; 1/2 cycle RMS steps
    • L-L, L-N, N-G RMS Variations: Sags/swells/interruptions
    • RMS Recordings V&I (32 pre-fault, 10K post-fault cycles)
    • Waveshape Recordings (2/6/2 cycles)
    • Low and Medium Frequent Transients - V&I
    • High Frequency Transients - V&I, 3% FS trigger
    • Harmonics Summary Parameters
    • Cross trigger V & I channels
    • RMS Event Characterization (IEEE or IEC)
    • Transient Event Characterization
  • Distortion/Power/Energy:
    • W, VA, VAR, TPF, DPF, Demand, Energy, etc.
    • IEEE 1459 Parameters of distorted and unbalanced
    • Harmonics/Interharmonics per IEC 1000-4-7
    • THD/Harmonic Spectrum (V,I,W) to 63rd at 50/60Hz; 16th at 400Hz
    • TID /Interharmonic Spectrum (V,I) to 63rd at 50/60Hz; 16th at 400Hz
    • Flicker per IEC 1000-4-15 (Pst,Plt,Sliding Plt)
    • Crest Factor, K Factor, Transformer Derating Factor, Telephone Interference Factor
    • Unbalance (max. rms deviation) & sequencing components
    • 5 User Spec Harmonics or Signaling Frequency
    • Vector/Arithmetic/Coincident Parameters
  • Monitoring/Compliance:
    • MIL-STD-1399 (US DoD)
    • IEEE 1159
    • IEC 61000-4-30 Class A
    • EN50160 Quality of Supply
    • Cur Inrush / Energization
    • Voltage Fault recording
    • Long Term Monitoring
    • Continuous Data Logging w/min/max/avg
  • (4) diffeial inputs, 1-600 Vrms, AC/DC, 0.1% rdg + 0.05% FS, 256 samples/cycle, 16 bit ADC
  • (4) inputs with CTs 0.1-6000 Arms CT-dependent, AC/DC, 0.1%rdg + CTs, 256 samples/cycle, 16 bit ADC
  • 1 MHz High Speed Sampling, 14 bit ADC, 1%FS
  • Frequency Range, 10m Hz resolution, 15-20 Hz, 45-65 Hz, or 350-450 Hz
  • Phase Lock Loop - Generator tracking
  • Phase Lock Loop - Standard PQ mode
  • Cycle-by-cycle analysis
  • 256 samples/cycle; 1/2 cycle RMS steps
  • L-L, L-N, N-G RMS Variations: Sags/swells/interruptions
  • RMS Recordings V&I (32 pre-fault, 10K post-fault cycles)
  • Waveshape Recordings (2/6/2 cycles)
  • Low and Medium Frequent Transients - V&I
  • High Frequency Transients - V&I, 3% FS trigger
  • Harmonics Summary Parameters
  • Cross trigger V & I channels
  • RMS Event Characterization (IEEE or IEC)
  • Transient Event Characterization
  • W, VA, VAR, TPF, DPF, Demand, Energy, etc.
  • IEEE 1459 Parameters of distorted and unbalanced
  • Harmonics/Interharmonics per IEC 1000-4-7
  • THD/Harmonic Spectrum (V,I,W) to 63rd at 50/60Hz; 16th at 400Hz
  • TID /Interharmonic Spectrum (V,I) to 63rd at 50/60Hz; 16th at 400Hz
  • Flicker per IEC 1000-4-15 (Pst,Plt,Sliding Plt)
  • Crest Factor, K Factor, Transformer Derating Factor, Telephone Interference Factor
  • Unbalance (max. rms deviation) & sequencing components
  • 5 User Spec Harmonics or Signaling Frequency
  • Vector/Arithmetic/Coincident Parameters
  • MIL-STD-1399 (US DoD)
  • IEEE 1159
  • IEC 61000-4-30 Class A
  • EN50160 Quality of Supply
  • Cur Inrush / Energization
  • Voltage Fault recording
  • Long Term Monitoring
  • Continuous Data Logging w/min/max/avg
  •     

    Devoluciones

    Si no estás completamente satisfecho con tu compra, simplemente devuelve el artículo en su estado original dentro de los 30 días posteriores a la recepción. Los artículos devueltos deben estar sin usar y en su embalaje original, junto con toda la documentación incluida. Emitiremos un reembolso completo al recibir el artículo, excluyendo el coste original del envío. Alternativamente, si lo prefieres, podemos cambiar el artículo.