EMC
EMC Compliance
9 kHz – 18 GHz Rango de frecuencia
CISPR 22, EN 55022, FCC Parte 15, MIL-STD-461 Estándares de cumplimiento
Emisiones radiadas y conducidas, inmunidad electromagnética Tipo de medición
50 Ω Impedancia de entrada
hasta 120 dB Rango dinámico

| Atributo | Valor |
|---|---|
| Rango de frecuencia | 9 kHz – 18 GHz |
| Estándares de cumplimiento | CISPR 22, EN 55022, FCC Parte 15, MIL-STD-461 |
| Tipo de medición | Emisiones radiadas y conducidas, inmunidad electromagnética |
| Impedancia de entrada | 50 Ω |
| Rango dinámico | hasta 120 dB |
| Interfaz de comunicación | USB, LAN (Ethernet), GPIB |
| Pantalla | Pantalla táctil TFT a color de 10,4 pulgadas |
| Alimentación eléctrica | 100 – 240 V CA, 50/60 Hz |
| Temperatura de funcionamiento | 0 °C a 50 °C |
| Dimensiones y peso | 426 mm × 177 mm × 497 mm; 18 kg |
EMC Compliance Options:
- HMS-X - HMS-EMC (HV213) - EMC option including preamplifier, activates all functions required for EMC precompliance measurements
- HMS-X - HMS-3G (HV212) - Bandwidth upgrade, increases frequency range from 1.6 GHz to 3 GHz
- HMS-X - HMS-TG (HV211) - Unlocks the built-in tracking generator (frequency range 5 MHz to 1.6 GHz/3 GHz, output level -20 dBm to 0 dBm)
| Model | Compliance |
|---|
The EMC precompliance set EMC-SET1 includes all necessary instruments to analyse typical EMC problems. This set contains a spectrum analyzer HMS-X incl. HMS-EMC option, a probe set HZ530, the HM6050-2 LISN for line conducted measurements and the HMExplorer software for EMC precompliance measurements.
Key Features
- Frequency range: 100 kHz to 1.6 GHz/3 GHz
- Spectral purity greater than -100 dBc/Hz (at 100 kHz)
- SWEEP from 20 ms to 1000 s
- Detectors: auto-, min-/max.-peak, sample, RMS, average, quasi-peak
- Miscellaneous marker/?marker and peak functions
- Tracking generator
- Frequency range: 5 MHz to 1.6 GHz/3 GHz
- Output level: -20 dBm to 0 dBm
- Directly export data to USB fl ash drive, RS-232/USB dual interfacefor remote control
- Fanless design and fast boot time