Fluke DSX-5000QI

| Atributo | Valor |
|---|---|
| Categoría de cable compatible | Cat 8/Clase I y II, Cat 7A/Clase FA, Cat 6A/Clase EA, Cat 6/Clase E, Cat 5e/Clase D |
| Límite de frecuencia | 2000 MHz |
| Estándares de certificación | ISO/IEC 11801, EN 50173, ANSI/TIA-568, IEEE 802.3 |
| Tiempo de prueba (Cat 6A) | 9 segundos por enlace |
| Memoria interna | Capacidad para almacenar hasta 10.000 resultados de prueba con gráficos |
| Pantalla | Pantalla táctil LCD a color de alta resolución |
| Interfaz de comunicación | USB, Wi-Fi (802.11 b/g/n), compatible con Fluke Networks LinkWare Live |
| Duración de la batería | Hasta 8 horas de uso continuo |
| Temperatura de funcionamiento | -10 °C a +50 °C |
| Precisión de medición | Nivel IV de precisión según estándares IEC 61935-1 |
| Model | DSX-5000QI |
|---|
FLUKE DSX-5000QI Versiv Cable Analyzer
The Fluke DSX-5000QI CableAnalyzer copper test solution, streamlines the testing and certification of twisted pair cabling for 10 Gigabit Ethernet deployments, covering Cat 5e, 6, 6A, and Class FA systems. It accelerates the certification process, ensuring accuracy and reducing common slowdowns like setup errors and result misinterpretation. With features like ProjX management, Taptive user interface, and LinkWare software, it caters to users of varying skill levels, enhancing efficiency and project management.
The Fluke DSX-5000QI performance includes a 10-second Cat 6A test, graphical fault analysis, and support for industry standards. It excels in accuracy, exceeding Level V standards, and supports balance measurements critical for noise immunity. The DSX-5000 CableAnalyzer is endorsed by cabling vendors worldwide, offering unmatched speed and efficiency for project completion and system acceptance.
Specifications for the FLUKE DSX-5000QI Versiv Cable Analyzer Include:
| Speed of Autotest | Full 2-way Autotest of Cat 5E or 6D or E: 9s (10s for Cat 6A/Class EA) |
| Max Frequency | 1200 MHz |
| TIA (Test Standard) | Cat 3, 4, 5, 5E, 6, 6A per TIA 568-C.2 |
| ISO/IEC (Test Standard) | Class C and D, E, Ea, F, FA certification per ISO/IEC 11801:2002 and amendments |