Manufacturer Logo
Kaelus

Kaelus iBA-2101B

Bench-top 20 W PIM analyser, UMTS 2100 band, 2-port reverse/forward
UMTS 2100 Frequency Band
2110-2170 MHz Transmit (TX)
1920-2080 MHz Receive (PIM)
0.1 to 25 W per tone (+20 to +44 dBm); 1 to 25 W on units built before mid-2018 Output Power
3rd, 5th, 7th, 9th and 11th order IM Orders
Attribute Value
Frequency Band UMTS 2100
Transmit (TX) 2110-2170 MHz
Receive (PIM) 1920-2080 MHz
Output Power 0.1 to 25 W per tone (+20 to +44 dBm); 1 to 25 W on units built before mid-2018
IM Orders 3rd, 5th, 7th, 9th and 11th order
Test Ports 2 (reverse PIM on each port, forward PIM port 1 to port 2)
Control External system controller with Kaelus PIM software
Mains Power 115-230 V, 50-60 Hz; 800 W
Kaelus iBA-2101B Options:
  • RTF module - Range to Fault module
  • ACE-1000A - Analyzer Calibration Extender for self-calibration
  • Bias-tee - Optional internal DC / AISG bias-tee
Formulario de calibración Kaelus iBA-2101B

Formulario de reparación Kaelus iBA-2101B
Maximum file size: 40MB

El Kaelus iBA-2101B es un analizador PIM de sobremesa y para montaje en rack para la banda UMTS 2100, de la serie iBA de 20 W. Es el modelo de dos puertos, que mide PIM inversa en cada puerto y PIM directa del puerto 1 al puerto 2.

La potencia es ajustable de 0,1 a 25 W por portadora y mide productos de intermodulación del 3.º al 11.º orden. Junto con un controlador y el software PIM de Kaelus, es adecuado para pruebas de producción y laboratorio de antenas, cables, conectores y filtros, y es compatible con el módulo Kaelus RTF y la herramienta de autocalibración ACE.

Testwall puede suministrar el Kaelus iBA-2101B usado, totalmente probado, con 12 meses de garantía y entrega en toda Europa. La calibración puede organizarse bajo petición antes del envío. Póngase en contacto con nosotros si necesita la calibración o reparación de su Kaelus iBA-2101B.