Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) DSOX1202G

Oscilloscope, 70/100/200 MHz, 2 Analog Channels, w/Built-in Waveform Generator
200 MHz Ancho de banda
2 canales analógicos Número de canales
2 GSa/s Tasa de muestreo máxima
1 Mpts Profundidad de memoria
Pantalla táctil WVGA de 7 pulgadas Pantalla
Solicitar ficha técnica
Atributo Valor
Ancho de banda 200 MHz
Número de canales 2 canales analógicos
Tasa de muestreo máxima 2 GSa/s
Profundidad de memoria 1 Mpts
Pantalla Pantalla táctil WVGA de 7 pulgadas
Generador de funciones integrado Sí, generador de forma de onda incorporado
Tasa de actualización de formas de onda 50.000 formas de onda por segundo
Resolución vertical 8 bits
Rango de base de tiempos 5 ns/div a 50 s/div
Conectividad USB, LAN (LXI), salida de pantalla
Formulario de calibración Keysight (Agilent) DSOX1202G

Formulario de reparación Keysight (Agilent) DSOX1202G
Maximum file size: 40MB

No Related Posts

Más información
ModelDSOX1202G

 Keysight (Agilent)  DSOX1202G Oscilloscope

 

   The  Keysight  / Agilent DSOX1202G Oscilloscope  is engineered to give you quality, industry-proven technology at unbelievably low prices.  Get professional-level functionality with industry-leading software analysis including standard serial bus analysis for the most popular serial bus standards, and 6-in-1 instrument integration.  The  DSOX1202G offers an integrated 20 MHz function generator with modulation capability.  Keysight  / Agilent DSOX1202G Oscilloscope is ideal for educational or design labs where bench space and budget are at a premium. The integrated function generator provides stimulus output of sine, square, ramp, pulse, DC and noise waveforms to your device under test. Add modulation to the signal with customizable AM, FM and FSK settings.

   The  Keysight (Agilent) DSOX1202G Oscilloscope  is a powerful protocol analyzer that enables hardware-based specialized serial communication analysis.  The DSOX1202G's frequency response analyzer capability is the perfect tool to help students understand the gain and phase performance of passive RLC circuits and amplifiers.  The voltmeter operates through probes connected to the oscilloscope channels, but its measurement is decoupled from the oscilloscope triggering system, so both the DVM and triggered oscilloscope measurements can be made with the same connection. You can quickly measure AC RMS, DC, and DC RMS without configuring the oscilloscope capture.  There is also an integrated 5-digit frequency counter inside Keysight  / Agilent  DSOX1202G Oscilloscope.  

 

Specifications for the  Keysight (Agilent) DSOX1202G Oscilloscope Include:

Bandwidth 70 MHz (std) up to 200 MHz
Number of Channels 2
Sample Rate 2 GSa/s
Memory Depth 2 M points

 

Clicky Copyright © 2013-present Magento, Inc. All rights reserved.