Teseq (Schaffner) NSG4070

Sistema de prueba de inmunidad RF conducida

Fabricante:
Modelo: Teseq (Schaffner) NSG4070
Descripción: Sistema de prueba de inmunidad RF conducida
Hoja de datos PDF: Teseq (Schaffner) NSG4070

Teseq NSG 4070 Conducted RF Immunity Test SystemThe Teseq NSG 4070, successor of the NSG 2070, is a multifunctional EMC immunity test system. Its large frequency range from 9 kHz to 1 GHz and its modular set-up using internal or external amplifiers enable a large variety of applications including tests according to IEC 61000-4-6, various BCI applications as well as signal generator and power meter for test systems as per IEC 61000-4-3, IEC 61000-4-20, IEC 61000-4-21 and many other applications. The powerful and easy to use fi rmware makes the NSG4070 independent from an external PC and control software, however it can also be remote controlled for system operation. A state-of-the-art data transfer of test and measurement data for documentation is provided by USB stick to be plugged into the front panel.Features of the Teseq NSG4070 include:

  • Integrated signal generator 9 kHz to 1 GHz
  • 3 power meter inputs 9 kHz to 1 GHz
  • Integrated power amplifier module for diffe applications
  • Multiple EUT monitoring options
  • 5.7“ TFT color display
  • Internal, menu-based control software
  • Basic remote control software and report generator included
  • Specifications of the Teseq NSG4070 include:Generator:

  • RF
    • Frequency range: 9 kHz – 1 GHz
    • Resolution: 1 Hz
    • Reference frequency: 10 MHz Reference output
  • RF Level
    • Level range: -60 dBm to +10 dBm
    • Resolution: 0.1 dB
    • Settling time: 10 ms
  • Amplitude modulation
    • Modulation depth: 0 – 100%
    • Modulation frequency range: 1 Hz – 50 kHz
    • Frequency resolution: 1 Hz
  • Pulse modulation
    • Rise / fall time (10% / 90%): < 1 µs
    • Modulation frequency range: 1 Hz – 50 kHz
    • Frequency resolution: 1 Hz
    • Duty cycle: 10% to 90%
  • External modulation
    • Delay time: < 1 µs / 180°
    • Period: min. 20 µs
    • Pulse width: min. 10 µs
  • Frequency range: 9 kHz – 1 GHz
  • Resolution: 1 Hz
  • Reference frequency: 10 MHz Reference output
  • Level range: -60 dBm to +10 dBm
  • Resolution: 0.1 dB
  • Settling time: 10 ms
  • Modulation depth: 0 – 100%
  • Modulation frequency range: 1 Hz – 50 kHz
  • Frequency resolution: 1 Hz
  • Rise / fall time (10% / 90%): < 1 µs
  • Modulation frequency range: 1 Hz – 50 kHz
  • Frequency resolution: 1 Hz
  • Duty cycle: 10% to 90%
  • Delay time: < 1 µs / 180°
  • Period: min. 20 µs
  • Pulse width: min. 10 µs
  • Power Meter

  • Frequency range: 9 kHz – 1 GHz
  • Linear measurement range
    • channel 1: -15 dBm to +27 dBm
    • channel 2,3: -25 dBm to +20 dBm
  • Max. input/no damage
    • channel 1-3: +28 dBm
  • Noise level: >6 dB below the measurement range
  • Input return loss: >20 dB (below 500 MHz), >17 dB (500 MHz to 1 GHz)
  • Connector: BNC socket, 50 O
  • Accuracy 150 kHz to 1 GHz, 10 to 30°C
    • channel 1 to 3: typ. channel 1, below 10 MHz: range >25 dBm typ. channel 2 and 3, below 10 MHz: range >17 dBm typ.
  • channel 1: -15 dBm to +27 dBm
  • channel 2,3: -25 dBm to +20 dBm
  • channel 1-3: +28 dBm
  • channel 1 to 3: typ. channel 1, below 10 MHz: range >25 dBm typ. channel 2 and 3, below 10 MHz: range >17 dBm typ.
  • Power Amplifier (75 Watt Version):

  • Frequency Range: 150 kHz – 230 MHz
  • Input Impedance: 50 O
  • Output Impedance: 50 O
  • Input Return Loss: min. 10 dB
  • Output Return Loss: nominal min. 9.5 dB, 0 dB without damage
  • Gain: min. 50 dB
  • Gain Flatness: max. +/- 3 dB
  • Saturated Output Power: min. 48.75 dBm
  • Max. input power linear without damage: < -3 dBm max. +10 dBm
  • 2nd harmonic distortion at nominal output power: typ. < -35 dBc
  • 3rd harmonic distortion at nominal output power: typ. < -18 dBc
  •     

    Teseq (Schaffner) NSG4070 Product Overview