The R&S ESR7 EMI Test Receiver is a dual instrument that measures electromagnetic disturbances while simultaneously functioning as a fully featured, powerful signal and spectrum analyzer for lab applications.   Rapid-fire-speed measuring occurs by the instrument's use of an FFT-based time domain scan and detailed analysis and history of disturbance signals is accomplished by realtime spectrum analysis using a wide variety of diagnostic tools. This robust and compact, dual instrument is user friendly with its straightforward display, intuitive touchscreen interface.

Features and Specifications of the R&S ESR7 EMI Test Receiver include:

  • Features
    • EMI test receiver and signal/spectrum analyzer combined in a single instrument
    • Compliant with CISPR 16-1-1 Ed. 3.1
    • Preselection with integrated 20 dB preamplifier
    • Ultra-fast time domain scan in addition to conventional stepped frequency scan
    • Realtime spectrum analysis with up to 40  MHz span for detailed investigation of disturbance signals
    • Powerful measurement and analysis functions in frequency and time domain
    • Time domain display with high resolution (50  Î¼s)
    • Automatic test routines
    • Convenient operation, straightforward display
    • Robust and compact - ideal for the mobile use
  • Specifications
    • Frequency
      • Frequency Range:   9  kHz to  7 GHz
    • Level
      • Max RF level (CW):
        • RF attenuation ‰¥ 10 dB; RF preamplifier off:   30 dBm (= 1 W)
        • RF attenuation ‰¥ 10 dB; RF preamplifier on:   23 dBm (= 0.2 W)
      • Max Pulse Voltage:
        • RF attenuation ‰¥ 10 dB:
          • Input 1:   150 V
          • Input 2:   450 V
      • Max Pulse Energy:
        • RF attenuation ‰¥ 10 dB; 10 μs
          • Input 1:   1 mWs
          • Input 2:     20 mWs
      • 1 dB Compression:
        • RF attenuation 0 dB; RF preamplifier and preselection off:   +3 dBm, nominal
    • IF and Resolution Bandwiths
      • Analyzer Mode (span ‰¥ 10 Hz) and Receiver Mode: 10 Hz to10 MHz ( €“3 dB) in 1/2/3/5/10 steps
      • Analyzer and Receiver Mode: 200 Hz, 9 kHz, 120 kHz ( €“6 dB), 1 MHz (impulse bandwidth)
      • Preselection:
        • Can be switched off in analyzer mode:   16 Fixed Filters
      • Preamplifier:
        • Can be switched on/off:   1 kHz to 7 GHz, 20 dB gain, nominal
      • Measurement Time:
        • Analyzer Mode (Sweep Time):
          • span = 0  Hz: 1  Î¼s to 16  000  s
          • span ‰¥ 10  Hz (swept): 1  ms to 16  000  s
          • span ‰¥ 10  Hz (FFT): 7  Î¼s to 16  000  s
        • Receiver Mode (Stepped Frequency Scan):   50 μs to 100 s (per frequency)
        • Receiver Mode (Time Domain Scan):   50 μs to 100 s (per frequency subrange)
      • Frequency Step Size:
        • Receiver Mode (Stepped Frequency Scan):   min. 1 Hz
        • Receiver Mode (Time Domain Scan):   0.25 × IF bandwidth
    • Detectors
      • Receiver Mode:
        • maximum peak
        • minimum peak
        • quasi-peak
        • RMS
        • average
        • average with meter time constant (CISPR average)
        • RMS average (CISPR-RMS)
    • Displayed Average Noise Level (DANL)
      • Receiver Mode, Nominal, Average Detector (AV), RF Attenuation 0 dB, Termination 50 Ω:
        • Preamplifier Off:
          • 500 MHz, bandwidth 120 kHz:   < 6 dBμV
          • 3 GHz, bandwidth 1 MHz:   < 17 dBμV
        • Preamplifier On:
          • 500 MHz, bandwidth 120 kHz:   < €“7 dBμV
          • 3 GHz, bandwidth 1 MHz:   < 5 dBμV
    • Number of Sweep (Trace) Points
      • Analyzer Mode (Standard):   101 to 32 001
      • Analyzer Mode (EMI):   101 to 200 001
      • Receiver Mode:   Max 4 000 000
      • Realtime Analyzer (Option):   801
    • Total Measurement Uncertainty
      • CW signal, level 0 dB to €“70 dB below reference level, S/N > 20 dB, auto  sweep  time,                       RF attenuation 10 dB, 20 dB, 30 dB, 40 dB, preselection on,                                                                                                        
        span/RBW<100, 95% confidence level, +200C to +300C
        • 9 kHz ‰¤ f < 3.6 GHz:   0.46 dB
        •  3.6 GHz ‰¤ f ‰¤ 7 GHz:   0.57 dB

 

No Related Posts

Devoluciones

Si no estás completamente satisfecho con tu compra, simplemente devuelve el artículo en su estado original dentro de los 30 días posteriores a la recepción. Los artículos devueltos deben estar sin usar y en su embalaje original, junto con toda la documentación incluida. Emitiremos un reembolso completo al recibir el artículo, excluyendo el coste original del envío. Alternativamente, si lo prefieres, podemos cambiar el artículo.