Sorensen
Sorensen SGI800-13
DC Power Supply, 800V, 13A, 10kW
800 V Tensión de salida máxima
13 A Corriente de salida máxima
10400 W Potencia máxima
CC (Corriente Continua) Tipo de salida
GPIB, RS-232 Interfaz de comunicación

| Atributo | Valor |
|---|---|
| Tensión de salida máxima | 800 V |
| Corriente de salida máxima | 13 A |
| Potencia máxima | 10400 W |
| Tipo de salida | CC (Corriente Continua) |
| Interfaz de comunicación | GPIB, RS-232 |
| Regulación de línea de tensión | 0,01% + 5 mV |
| Regulación de carga de tensión | 0,01% + 5 mV |
| Tensión de entrada (CA) | 208/240 V CA, trifásico |
| Frecuencia de entrada | 47 - 63 Hz |
| Factor de forma | Montaje en rack 3U |
Sorensen SGI800-13 Options:
- SGI800-13 - 0A - Remote Control: No Option
- SGI800-13 - 1A - Remote Control: IEEE-488.2 + RS-232C
- SGI800-13 - 1C - Remote Control: Ethernet + RS-232C
- SGI800-13 - 1D - Remote Control: Isolated Analog Control
- SGI800-13 - 2A - Remote Control: Combined Options 1A+1D
- SGI800-13 - 2G - Remote Control: Combined Options 1C+1D
- SGI800-13 - C - Input Voltage: 187/242VAC, 3 Phase
- SGI800-13 - D - Input Voltage: 342/440VAC, 3 Phase
- SGI800-13 - E - Input Voltage: 396/528VAC, 3 Phase
- SGI800-13 - AA - Process Option: No Option
- SGI800-13 - AB - Process Option: Certificate of Calibration to ANSI/NCSL Z540-1 (includes Test Data)
- SGI800-13 - AJ - Modification: Front panel dust filter - factory installed - 3U unit only
- SGI800-13 - PF - Modification: Passive power factor correction to 0.9
- SGI800-13 - 890-453-03 - Accessory: Paralleling Cable (for up to 5 units, requires one cable per unit placed in parallel)
- SGI800-13 - K550212-01 - Accessory: 3U Rack Slides (for 5kW, 10kW and 15kW models)
- SGI800-13 - K550532-01 - Accessory: Front panel dust filter - field installation kit - 3U unit only
- SGI800-13 - 5551082-01 - Accessory: Optional AC input cover kit - 3U unit only
| Model | SGI800-13 |
|---|
SORENSEN SGI800-12.5 DC Power Supply, 800V, 12.5A, 10kW (call for availability)
The Sorensen SGI800-12.5 DC Power Supply is a high powered, programmable power supply designed for exceptional load transient response, low noise, and the highest power density in the industry. The power density is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units.
The Sorensen SGI800-12.5 DC Power Supply (SGI = Sorensen General Purpose Intelligent) combines onboard intelligent controls with the outstanding power electronics common to all SG family supplies. These controls enable sophisticated sequencing, constant power mode and save/recall of instrument settings. Looping of sequences makes the Sorensen SGI800-12.5 DC Power Supply ideal for repetitive testing. An impressive vacuum fluorescent graphical display in eight languages, context sensitive "soft" keys and front panel keyboard simplify programming of the Sorensen SGI800-12.5 DC Power Supply. Features and Specifications of the Sorensen SGA800-12.5 DC Power Supply include:High Power Density: Up to 15 kW in a 3U chassis Wide Voltage Range: 0-10V up to 0-800V, in increments of 5 kW from 5 to 30 kW Fast Load Transient Response: Protection from undesired voltage excursions Low RMS and P-P Noise: Suitable for the most sensitive applications Parallelable up to 150 kW: Expandable as your requirement grows Modular Design: Upgradeable for the ultimate in investment protection Sequencing: Program custom waveforms Easy-to-read Fluorescent Display: SGI supports English, French, German, Italian, Spanish, Chinese, Japanese, and Korean languages 16-bit Resolution: Optional IEEE-488.2 + RS-232C + Ethernet provides precise control Ethernet Control: LXI Class C compliant communication through integrated web server Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only) Hardware Trigger: Ethernet Option Only Common:
Remote Sense: Terminals are provided to sense output voltage at point of load. Maximum line drop 5% of rated voltage per line for 40-100V models, line drop 1V of rated voltage per line for 10-20V models, 1.5V for 30V models, 2% of rated voltage per line for models 160V and greater. (Greater line drop is allowed, but output regulation specifications no longer apply). Parallel Operation: Up to 5 units may be paralleled for additional cur within the power supply single-unit specifications, with exception of the DC output cur set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units, contact factory. Series Operation: Up to 2 units Input:
Nominal Voltage 3 phase, 3 wire + ground: Frequency: 47 – 63Hz , 400Hz Power Factor: Protection: ½ cycle ride-though on all three phases, 3 cycle ride through on single phase; missing phase shutdown (800V model 6.4 msec on all 3 phases) 208/220 VAC (operating range 187 - 242 VAC) 380/400 VAC (operating range 342 - 440 VAC) 440/480 VAC (operating range 396 - 528 VAC) >0.9 typical for 208/220 VAC input (10V - 800V) >0.78 typical for 380/400 VAC input (40V - 800V) >0.9 typical for 380/480 VAC input (10V - 30V) >0.7 typical for 440/480 VAC input (40V - 800V) >0.9 typical for 440/480 VAC input (10V - 30V) Output:
Voltage and Cur Range: 800V, 12.5A, 10kW Ripple & Noise: rms(20Hz-300kHz): 80mV p-p: 500mV Programming & Read-Back Specifications:
Front Panel Display: Remote Analog Interface: Remote Digital Interface: OVP: User I/O: Programming: Read-Back Monitoring: Knob control & Display read-back Accuracy: Resolution: 4.0 digits (40-800V) +/- 0.1% of voltage at full scale (40-800V) +/- 0.4% of cur at full scale Accuracy: Resolution: 4.0 digits Voltage: +/- 0.1% of full scale Cur: +/- 0.4% of full scale Programming: Read-Back Monitoring: 25-pin D-sub connector (0~5 V or 0~10 V) Accuracy: Voltage: +/-0.25% of full scale Cur: (40-800V) 0.8% of full scale Accuracy: (40-800V) +/-1.0% of full scale Programming: Read-Back Monitoring: RS-232C (Standard on SGI), Optional IEEE-488.2 and Optional LXI Compliant 10/100 base-T Ethernet Accuracy: Resolution: +/-0.002% of full scale Voltage: +/- 0.1% of full scale Cur: +/- 0.4% of full scale Accuracy: Resolution: +/-0.002% of full scale Voltage: +/- 0.15% of full scale Cur: +/- 0.4% of full scale Programming: Programming range: 5-110% Configured from front panel, remote analog or via optional digital inputs Accuracy: +/- 1% of full scale Resolution: +/-0.002% of full scale Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
The Sorensen SGI800-13 is a Programmable Precision High Power DC Power Supply that is designed for exceptional load transient response, low noise and high power density which is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units. The SGI800-13 combines onboard intelligent controls with outstanding power electronics. These controls enable sophisticated sequencing, constant power mode and save/recall of instrument settings. Looping of sequences makes the SGI800-13 ideal for repetitive testing. An impressive vacuum fluorescent graphical display in eight languages, context sensitive “soft” keys and front panel keyboard simplify programming of the SGI800-13.
Features of the Sorensen SGI800-13 include:
High Power Density: 10kW in a 3U chassis Wide Voltage Range: 0-800V and 0-13 Amps Fast Load Transient Response: Protection from undesired voltage excursions Low RMS and P-P Noise: Suitable for the most sensitive applications Parallelable up to 150 kW: Expandable as your requirement grows Modular Design: Upgradeable for the ultimate in investment protection Sequencing: Program custom waveforms Easy-to-read Fluorescent Display: Supports English, French, German, Italian, Spanish, Chinese, Japanese, and Korean languages 16-bit Resolution: Optional IEEE-488.2 + RS-232C + Ethernet provides precise control Ethernet Control: LXI Class C compliant communication through integrated web server Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only) Hardware Trigger: Ethernet Option Only Specifications of the Sorensen SGI800-13 include:
Common:Remote Sense: Load-line loss compensation for models <= 100 V is 10% above full scale voltage total (5% per load-line), and models > 100 V is 4% above full scale voltage total (2% per load-line). Parallel Operation: Up to 5 units may be paralleled for additional cur within the power supply single-unit specifications, with exception of the DC output cur set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units,contact factory. Series Operation: Up to 2 units (see Output Float Voltage) Input: Nominal Voltage 3 phase, 3 wire + ground: 208/220 VAC (operating range 187 - 242 VAC); 380/400 VAC (operating range 342 - 440 VAC); and 440/480 VAC (operating range 396 - 528 VAC) Frequency: 47 – 63Hz (optional 400Hz @ 208VAC, does not carry CE, UL or CSA markings) Power Factor: >0.9 typical at 208/220 VAC input; >0.78 typical at 380/400 VAC input; and >0.69 typical at 440/480 VAC input Protection (typical): ½ cycle ride-though on all three phases, 3 cycle ride through on single phase; missing phase shutdown (800V model 6.4 msec on all 3 phases) Environmental: Operating Temperature: 0 to 50º C Storage Temperature: -25º C to 65º C Humidity Range: Relative humidity up to 95% non-condensing, 0º C – 50º C Altitude: Operating full power available up to 5,000 ft. (~1,500 m), derate 10% of full power for every 1,000 feet higher; non-operating to 40,000 ft. (~12,000 m) Cooling: Front and side air inlet, rear exhaust. Temperature controlled, variable speed fans. Units may be stacked without spacing. Regulatory: Certified to UL/CSA 61010 and IEC/EN 61010-1, CE Compliant, Semi-F47 Compliant Front Panel Dust Filter: 30 PPI (Pores Per Inch) - must ensure adequate airflow and / or derate max. temperature. 3U unit only. Physical: Dimensions: Width: 19.00” (48.3 cm), Depth 25.0” (63.5 cm) Height: 5-15 kW units: 3U – 5.25” rack mount (13.34 cm) 20-30 kW units: 6U – 10.5” rack mount (26.67 cm) Weight: 3U < 80 lbs. (36 kg) 6U Output: Ripple & Noise (Voltage Mode, Typical): Ripple and noise specified at full load, nominal AC input. Noise measured with 6ft. cable, 1µf at load Ripple (Cur Mode): <+/- 0.04% of full scale rms cur DC Voltage Slew Rate: 45A / ms typical - resistive load Line Regulation (with sense wires used): (±10% of nominal AC input, constant load); Voltage Mode: +/- 0.01% of full scale; and Cur Mode: +/- 0.05% of full scale Load Regulation (with sense wires used): no load to full load, nominal AC input); Voltage Mode: +/- 0.02% of full scale; and Cur Mode: +/- 0.1% of full scale Load Transient Response: Recovers within 1ms to +/-0.75% of full-scale of steadystate output for a 50% to 100% or 100% to 50% load change Efficiency: 87% typical at nominal line and max load Stability: ±0.05% of set point after 30 minute warm-up and over 8 hours at fixed line, load and temperature Temperature Coefficient: 0.02%/ C of maximum output voltage rating for voltage set point 0.03%/ C of maximum output cur rating for cur set point Output Float Voltage: Negative terminal within +/- 300 V of chassis potential. (We recommend the use of optional isolated analog Interface (IAI).) Supplies in “series” should be the same output voltage/cur. Programming Specifications of the Sorensen SGI800-13 include:
Front Panel Display:Voltage Accuracy: +/- 0.1% of full scale Cur Accuracy: +/- 0.4% of full scale Resolution: 4.0 digits Remote Analog Interface:
Voltage Accuracy: +/-0.25% of full scale for 0-5 V range, +/-0.5% of fullscale for 0-10 V range Cur Accuracy: 0.8% of full scale Remote Digital Interface: Voltage Accuracy: +/- 0.1% of full scale Cur Accuracy: +/- 0.4% of full scale Resolution: +/-0.002% of full scale OVP: Accuracy: +/- 1% of full scale Resolution: +/-0.002% of full scale User I/O: Disconnect & Polarity-reversal relay control (Only available with Ethernet Option) Read-Back / Monitoring Specifications of the Sorensen SGI800-13 include:
Front Panel Display:Voltage Accuracy: +/- 0.1% of full scale Cur Accuracy: +/- 0.4% of full scale Resolution: 4.0 digits Remote Analog Interface:
Accuracy: +/-1.0% of full scale (0 - 10V) Remote Digital Interface: Voltage Accuracy: +/- 0.1% of full scale Cur Accuracy: +/- 0.4% of full scale Resolution: +/-0.002% of full scale User I/O: Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
The Sorensen SGI800-12.5 DC Power Supply is a high powered, programmable power supply designed for exceptional load transient response, low noise, and the highest power density in the industry. The power density is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units.
The Sorensen SGI800-12.5 DC Power Supply (SGI = Sorensen General Purpose Intelligent) combines onboard intelligent controls with the outstanding power electronics common to all SG family supplies. These controls enable sophisticated sequencing, constant power mode and save/recall of instrument settings. Looping of sequences makes the Sorensen SGI800-12.5 DC Power Supply ideal for repetitive testing. An impressive vacuum fluorescent graphical display in eight languages, context sensitive "soft" keys and front panel keyboard simplify programming of the Sorensen SGI800-12.5 DC Power Supply. Features and Specifications of the Sorensen SGA800-12.5 DC Power Supply include:
- 208/220 VAC (operating range 187 - 242 VAC)
- 380/400 VAC (operating range 342 - 440 VAC)
- 440/480 VAC (operating range 396 - 528 VAC)
- >0.9 typical for 208/220 VAC input (10V - 800V)
- >0.78 typical for 380/400 VAC input (40V - 800V)
- >0.9 typical for 380/480 VAC input (10V - 30V)
- >0.7 typical for 440/480 VAC input (40V - 800V)
- >0.9 typical for 440/480 VAC input (10V - 30V)
- 208/220 VAC (operating range 187 - 242 VAC)
- 380/400 VAC (operating range 342 - 440 VAC)
- 440/480 VAC (operating range 396 - 528 VAC)
- >0.9 typical for 208/220 VAC input (10V - 800V)
- >0.78 typical for 380/400 VAC input (40V - 800V)
- >0.9 typical for 380/480 VAC input (10V - 30V)
- >0.7 typical for 440/480 VAC input (40V - 800V)
- >0.9 typical for 440/480 VAC input (10V - 30V)
- rms(20Hz-300kHz): 80mV
- p-p: 500mV
- rms(20Hz-300kHz): 80mV
- p-p: 500mV
- Programming:
- Accuracy:
- (40-800V) +/- 0.1% of voltage at full scale
- (40-800V) +/- 0.4% of cur at full scale
- Resolution: 4.0 digits
- Read-Back Monitoring:
- Accuracy:
- Voltage: +/- 0.1% of full scale
- Cur: +/- 0.4% of full scale
- Resolution: 4.0 digits
- Knob control & Display read-back
- Programming:
- Accuracy:
- Voltage: +/-0.25% of full scale
- Cur: (40-800V) 0.8% of full scale
- Read-Back Monitoring:
- Accuracy: (40-800V) +/-1.0% of full scale
- 25-pin D-sub connector (0~5 V or 0~10 V)
- Programming:
- Accuracy:
- Voltage: +/- 0.1% of full scale
- Cur: +/- 0.4% of full scale
- Resolution: +/-0.002% of full scale
- Read-Back Monitoring:
- Accuracy:
- Voltage: +/- 0.15% of full scale
- Cur: +/- 0.4% of full scale
- Resolution: +/-0.002% of full scale
- RS-232C (Standard on SGI), Optional IEEE-488.2 and Optional LXI Compliant 10/100 base-T Ethernet
- Programming:
- Accuracy: +/- 1% of full scale
- Resolution: +/-0.002% of full scale
- Programming range: 5-110% Configured from front panel, remote analog or via optional digital inputs
- Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
- Accuracy:
- (40-800V) +/- 0.1% of voltage at full scale
- (40-800V) +/- 0.4% of cur at full scale
- Resolution: 4.0 digits
- Accuracy:
- Voltage: +/- 0.1% of full scale
- Cur: +/- 0.4% of full scale
- Resolution: 4.0 digits
- (40-800V) +/- 0.1% of voltage at full scale
- (40-800V) +/- 0.4% of cur at full scale
- Voltage: +/- 0.1% of full scale
- Cur: +/- 0.4% of full scale
- Accuracy:
- Voltage: +/-0.25% of full scale
- Cur: (40-800V) 0.8% of full scale
- Accuracy: (40-800V) +/-1.0% of full scale
- Voltage: +/-0.25% of full scale
- Cur: (40-800V) 0.8% of full scale
- Accuracy:
- Voltage: +/- 0.1% of full scale
- Cur: +/- 0.4% of full scale
- Resolution: +/-0.002% of full scale
- Accuracy:
- Voltage: +/- 0.15% of full scale
- Cur: +/- 0.4% of full scale
- Resolution: +/-0.002% of full scale
- Voltage: +/- 0.1% of full scale
- Cur: +/- 0.4% of full scale
- Voltage: +/- 0.15% of full scale
- Cur: +/- 0.4% of full scale
- Accuracy: +/- 1% of full scale
- Resolution: +/-0.002% of full scale
Product Overview
Sorensen SGI800-13 (call for availability)
The Sorensen SGI800-13 is a Programmable Precision High Power DC Power Supply that is designed for exceptional load transient response, low noise and high power density which is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units. The SGI800-13 combines onboard intelligent controls with outstanding power electronics. These controls enable sophisticated sequencing, constant power mode and save/recall of instrument settings. Looping of sequences makes the SGI800-13 ideal for repetitive testing. An impressive vacuum fluorescent graphical display in eight languages, context sensitive “soft” keys and front panel keyboard simplify programming of the SGI800-13.
Features of the Sorensen SGI800-13 include:
Common:
Front Panel Display:
Front Panel Display: