Tektronix DPO5034

| Atributo | Valor |
|---|---|
| Ancho de banda | 350 MHz |
| Número de canales | 4 canales analógicos |
| Frecuencia de muestreo | 5 GS/s en todos los canales |
| Longitud de registro | 25 M puntos |
| Resolución vertical | 8 bits |
| Pantalla | Pantalla táctil LCD de 10,4 pulgadas (SVGA) |
| Tasa de captura de formas de onda | hasta 250.000 formas de onda por segundo |
| Sensibilidad de entrada | 1 mV/div a 10 V/div |
| Impedancia de entrada | 1 MΩ o 50 Ω |
| Conectividad | USB, LAN (LXI), puerto de impresora, ranura para módulo de aplicaciones |
Tektronix DPO5034 Options:
- DPO5034 - 2RL - 25 M/Ch record length
- DPO5034 - 5RL - 50 M/Ch record length
- DPO5034 - 10RL - 125 M/Ch record length
- DPO5034 - SSD - Solid state hard disk drive, ≥300 GB
- DPO5034 - DDRA - DDR Memory bus analysis (Requires Opt. DJA) (Available on 1 GHz and 2 GHz models only.)
- DPO5034 - DJA - Jitter and Eye Analysis Tools – Advanced (DPOJET)
- DPO5034 - ET3 - Ethernet compliance test (Requires TF-GBE-BTP or TF-GBE-ATP Ethernet Test Fixture)
- DPO5034 - HSIC - USB HSIC protocol decode and electrical validation (Available on 2 GHz models only.)
- DPO5034 - LT - Waveform limit testing
- DPO5034 - MOST - MOST Essentials – Electrical compliance and debug test solution for MOST50 and MOST150 (Requires Opt. DJA)
- DPO5034 - MTM - Mask testing
- DPO5034 - PWR - Power measurement and analysis
- DPO5034 - SR-AERO - Aerospace serial triggering and analysis (MIL-STD-1553)
- DPO5034 - SR-AUTO - Automotive serial triggering and analysis (CAN/LIN/FlexRay)
- DPO5034 - SR-COMP - Computer serial triggering and analysis (RS-232/422/485/UART)
- DPO5034 - SR-DPHY - MIPI® D-PHY serial analysis
- DPO5034 - SR-EMBD - Embedded serial triggering and analysis (I2C, SPI)
- DPO5034 - SR-ENET - Ethernet serial triggering and analysis (10BASE-T, 100BASE-TX)
- DPO5034 - SR-PCIE - PCI Express serial analysis (Available on ≥1 GHz models only.)
- DPO5034 - SR-USB - USB 2.0 serial triggering and analysis (LS, FS, HS)
- DPO5034 - SR-810B - 8b/10b serial analysis
- DPO5034 - SVA - SignalVu® AM/FM/PM/Direct audio measurements (Requires Opt. SVE)
- DPO5034 - SVE - SignalVu® Essentials – Vector signal analysis software
- DPO5034 - SVM - SignalVu® General purpose modulation analysis (Requires Opt. SVE)
- DPO5034 - SVP - SignalVu® Pulse – Advanced signal analysis (Requires Opt. SVE)
- DPO5034 - SVT - SignalVu® Settling time measurements – frequency and phase (Requires Opt. SVE)
- DPO5034 - USB - USB 2.0 Compliance testing (Requires TDSUSBF (USB Test Fixture). 2 GHz bandwidth required for high-speed USB)
- DPO5034 - USBPWR - Automated compliance test solution for USB power adapters
- DPO5034 - VET - Visual Trigger and Search
- DPO5034 - VNM - CAN/LIN Protocol analysis software
- DPO5034 - PS1 - Power Solution Bundle: DPOPWR, P5205A, TCP0030A, TPA-BNC, 067-1686-xx (Deskew fixture), 119-7465-xx (external probe power supply)
- DPO5034 - PS2 - Power Solution Bundle: DPOPWR, THDP0200, TCP0030A, 067-1686-xx (Deskew fixture)
- DPO5034 - PS3 - Power Solution Bundle: DPOPWR, TMDP0200, TCP0020, 067-1686-xx (Deskew fixture)
- DPO5034 - A0 - North America power plug (115 V, 60 Hz)
- DPO5034 - A1 - Universal Euro power plug (220 V, 50 Hz)
- DPO5034 - A2 - United Kingdom power plug (240 V, 50 Hz)
- DPO5034 - A3 - Australia power plug (240 V, 50 Hz)
- DPO5034 - A5 - Switzerland power plug (220 V, 50 Hz)
- DPO5034 - A6 - Japan power plug (100 V, 110/120 V, 60 Hz)
- DPO5034 - A10 - China power plug (50 Hz)
- DPO5034 - A11 - India power plug (50 Hz)
- DPO5034 - A12 - Brazil power plug (60 Hz)
- DPO5034 - A99 - No power cord
- DPO5034 - L0 - English manual
- DPO5034 - L1 - French manual
- DPO5034 - L3 - German manual
- DPO5034 - L5 - Japanese manual
- DPO5034 - L7 - Simplified Chinese manual
- DPO5034 - L8 - Traditional Chinese manual
- DPO5034 - L9 - Korean manual
- DPO5034 - L10 - Russian manual
- DPO5034 - L99 - No manual
- DPO5034 - C3 - Calibration Service 3 Years
- DPO5034 - C5 - Calibration Service 5 Years
- DPO5034 - D1 - Calibration Data Report
- DPO5034 - D3 - Calibration Data Report 3 Years (with Opt. C3)
- DPO5034 - D5 - Calibration Data Report 5 Years (with Opt. C5)
- DPO5034 - G3 - Complete Care 3 Years (includes loaner, scheduled calibration, and more)
- DPO5034 - G5 - Complete Care 5 Years (includes loaner, scheduled calibration, and more)
- DPO5034 - R3 - Repair Service 3 Years (including warranty)
- DPO5034 - R5 - Repair Service 5 Years (including warranty)
| Model | DPO5034 |
|---|
El Tektronix DPO5034 incluye 4 canales analógicos con ancho de banda de 350 MHz y tasa de muestreo de hasta 5 GS/s (10 GS/s en uno o dos canales), con una longitud de registro estándar de 12,5 M. FastAcq® ofrece más de 250 000 formas de onda/s y FastFrame™ captura segmentada hasta 290 000 segmentos y más de 310 000 formas de onda/s—ideal para señales de alta velocidad.
Con interfaz Wave Inspector®, 53 mediciones automáticas, FFT, histogramas, diagramas de ojo, análisis de jitter, decodificación opcional de protocolos y pantalla táctil XGA de 10,4″, es perfecto para análisis profundo de señales.
Testwall puede suministrar el Tektronix DPO5034 usado, completamente probado. Con soporte experto y entrega global, Testwall garantiza instrumentos de alto rendimiento con fiabilidad y calidad de servicio inigualables. Contáctenos para calibración o reparación del Tektronix DPO5034.