Tektronix TCP0030A

FabricanteTektronix
ModeloTCP0030A
ProductoCurrent Probe, AC/DC, DC to 120 MHz 30 A DC
TypeUsed

 

Tektronix TCP0030

Tektronix TCP0030

Tektronix TCP305A

Tektronix TCP305A

Obtener cotización
SKU
143507
The Tekronix TCP0030 AC/DC Cur Probe is a high-performance and easy-to-use probe that enhances the bandwidth with selectable measurement ranges and also provides low-cur measurement  capability and accuracy. The Tektronix TCP0030 Probe is designed specifically for those Oscilloscopes that have the TekVPI™ probe interface.Features and Specifications of the Tektronix TCP0030 AC/DC Cur Probe include:
  • Features:
    • Easy-to-use and accurate AC/DC cur measurements
    • Connects directly to Oscilloscopes with the TekVPI™ Probe Interface
    • Provides automatic units scaling and readout on the Oscilloscope display
    • Embeds the probe characteristics within the Oscilloscope
    • Fully programmable over the Oscilloscope's interface
    • Split-core construction allows easy circuit connection
    • High accuracy with typically less than 1% DC gain error
    • Accurately measures cur levels as low as 1 mA
    • Low Noise and DC Drift
    • Easy to degauss and autozero
    • Setup controls and probe status/diagnostic indicators are provided on both the probe hardware, and through an easy-to-access Oscilloscope UI display menu
    • Remote GPIB/USB probe control through the Oscilloscope
    • Safety certified for U.S. and Canada
    • Applications:
      • Power supplies
      • Semiconductor devices
      • Power inverters/converters
      • Electronic ballasts
      • Industrial/consumer electronics
      • Mobile communications
      • Motor drives
      • Transportation systems
  • Specifications:
    • Bandwidth:  DC to ≥120 MHz
    • Rise time:  ≤2.92 ns
    • Max RMS cur:  30 A
    • Max peak pulse cur:  50 A
    • Jaw Diameter: 5mm
    • Certified for bare wire voltages up to 150 V CAT II
    • Minimum sensitivity:
      • 1 mA (on Oscilloscopes that support 1 mV/div setting)
      • AC Coupling (on Oscilloscopes that support AC/DC coupling)
    • Cur ranges:  5 A and 30 A
    • DC accuracy:
      • Typical:  ±1%
      • Warranted:  ±3%
    • Max amp-second product:  500 Aμs (in 30 A Range)
    • Insertion impedance:
      • 1 mΩ at 10 kHz
      • 3.5 mΩ at 100 kHz
      • 0.08 Ω at 1 MHz
      • 0.15 Ω at 10 MHz
      • 0.7 Ω at 100 MHz
      • 0.85 Ω at 120 MHz
    • Signal delay:  14.5 ns
  • Easy-to-use and accurate AC/DC cur measurements
  • Connects directly to Oscilloscopes with the TekVPI™ Probe Interface
  • Provides automatic units scaling and readout on the Oscilloscope display
  • Embeds the probe characteristics within the Oscilloscope
  • Fully programmable over the Oscilloscope's interface
  • Split-core construction allows easy circuit connection
  • High accuracy with typically less than 1% DC gain error
  • Accurately measures cur levels as low as 1 mA
  • Low Noise and DC Drift
  • Easy to degauss and autozero
  • Setup controls and probe status/diagnostic indicators are provided on both the probe hardware, and through an easy-to-access Oscilloscope UI display menu
  • Remote GPIB/USB probe control through the Oscilloscope
  • Safety certified for U.S. and Canada
  • Applications:
    • Power supplies
    • Semiconductor devices
    • Power inverters/converters
    • Electronic ballasts
    • Industrial/consumer electronics
    • Mobile communications
    • Motor drives
    • Transportation systems
  • Power supplies
  • Semiconductor devices
  • Power inverters/converters
  • Electronic ballasts
  • Industrial/consumer electronics
  • Mobile communications
  • Motor drives
  • Transportation systems
  • Bandwidth:  DC to ≥120 MHz
  • Rise time:  ≤2.92 ns
  • Max RMS cur:  30 A
  • Max peak pulse cur:  50 A
  • Jaw Diameter: 5mm
  • Certified for bare wire voltages up to 150 V CAT II
  • Minimum sensitivity:
    • 1 mA (on Oscilloscopes that support 1 mV/div setting)
    • AC Coupling (on Oscilloscopes that support AC/DC coupling)
  • Cur ranges:  5 A and 30 A
  • DC accuracy:
    • Typical:  ±1%
    • Warranted:  ±3%
  • Max amp-second product:  500 Aμs (in 30 A Range)
  • Insertion impedance:
    • 1 mΩ at 10 kHz
    • 3.5 mΩ at 100 kHz
    • 0.08 Ω at 1 MHz
    • 0.15 Ω at 10 MHz
    • 0.7 Ω at 100 MHz
    • 0.85 Ω at 120 MHz
  • Signal delay:  14.5 ns
  • 1 mA (on Oscilloscopes that support 1 mV/div setting)
  • AC Coupling (on Oscilloscopes that support AC/DC coupling)
  • Typical:  ±1%
  • Warranted:  ±3%
  • 1 mΩ at 10 kHz
  • 3.5 mΩ at 100 kHz
  • 0.08 Ω at 1 MHz
  • 0.15 Ω at 10 MHz
  • 0.7 Ω at 100 MHz
  • 0.85 Ω at 120 MHz
  •     

    Devoluciones

    Si no estás completamente satisfecho con tu compra, simplemente devuelve el artículo en su estado original dentro de los 30 días posteriores a la recepción. Los artículos devueltos deben estar sin usar y en su embalaje original, junto con toda la documentación incluida. Emitiremos un reembolso completo al recibir el artículo, excluyendo el coste original del envío. Alternativamente, si lo prefieres, podemos cambiar el artículo.