Tektronix TCP305A

FabricanteTektronix
ModeloTCP305A
ProductoCurrent Probe, AC/DC, DC to 50 MHz 50 A DC
TipoUsado

 

Tektronix TCP0030A

Tektronix TCP0030A

Tektronix TCP312A

Tektronix TCP312A

Obtener cotización
SKU
143573
Tektronix TCP305 PROBEThe Tektronix TCP305 Cur Probe is a split-core probe that uses both transformer and Hall effect technology. When connected to Tektronix Oscilloscopes with TEKPROBE Level II, TekConnect (w/ TCA-BNC), or TekVPI (w/ TPA-BNC) interfaces, the Tektronix TCP305 probe makes cur measurements and calculations simple and easy.Features and Specifications of the TCP305 Cur Probe include:
  • Features:
    • AC/DC measurement capabilities
    • Automatic Scaling and Units
      • Requires a TDS TEKPROBE Oscilloscope or a TekConnect oscilliscope with TCA-BNC
      • Oscilloscope on-screen readout of magnitude and amps
      • Reduces measurement errors with no more hand calculations
    • AC/DC input coupling
    • Low insertion impedance reduces DUT loading
    • Split-core design allows easy circuit connection
    • Status Indicators provide visual operating status and notification of potential error conditions including:
      • Degauss, Probe open, Overload, Not terminated into 50 Ω, Noncompatible probe type
    • Lower DC drift and noise allows improved low-level cur measurements
    • Complies with IEC standards
    • Applications:
      • Development and analysis solutions for designers, installers, and service personnel in Telecomm, Data Comm, computer, and semiconductor power electronics environments for:
        • Power supplies (switching and linear)
        • Semiconductor devices (SCRs, IGBTs, MOSFETs, CMOS, BJTs)
        • Power Inverters/Converters
        • Electronic ballasts
        • Industrial/Consumer electronics
        • Mobile communications (phone, satellite, relay stations)
        • Motor drives
        • Transportation systems (electronic vehicles and trains, locomotives, avionics)
  • Specifications of TCP305 Probe w/ TCPA300 Amplifier:
    • Characteristic:
      • Bandwidth (-3 dB):  DC - 50 MHz
      • Rise Time:  ≤7 ns
      • Maximum Cur Ratings: 
        • High-cur Sensitivity Range: 10 A/V Range:
          • DC (continuous):  50 A
          • RMS (sinusoidal):  35.4 A
          • Peak Pulse:  50 A
        • Low-cur Sensitivity Range:  5 A/V Range:
          • DC (continuous):  25 A
          • RMS (sinusoidal):  17.7 A
          • Peak Pulse:  50 A
      • DC Accuracy (operating temp 0 °C to 50 °C):  ±3% of reading
      • DC Accuracy, typical (operating temp 23 °C ±5 °C):  ±1% of reading
    • Nominal:
      • Maximum Bare Wire Voltage:  For use with insulated wires only
      • Lowest Measurable Cur (at ±3% accuracy at DC):
        • 5 mA
        • Scope set to 1 mV/div and 20 MHz BW limited
      • Insertion Impedance:
        • 0.035 Ω at 1 MHz
        • 0.12 Ω at 10 MHz
        • 0.4 Ω at 50 MHz
    • Typical:
      • Maximum Amp-Second Product (based on amplifier range setting):
        • 500 AμS – 5 A/V
        • NA - 10 A/V
      • AC-coupling Low-frequency Bandwidth (Low Pass – 3 dB point): 
      • Displayed RMS Noise (at 20 MHz bandwidth limit):  ≤1.25 mARMS
      • Signal Delay (delay to output BNC):  19 ns
      • Probe Amplifier Inputs:  1
      • Probe Open Indicator:  Yes
      • Overload Indicator:  Yes
      • Termination Indicator:  Yes
      • Noncompatible Probe Indicator:  Yes
  • AC/DC measurement capabilities
  • Automatic Scaling and Units
    • Requires a TDS TEKPROBE Oscilloscope or a TekConnect oscilliscope with TCA-BNC
    • Oscilloscope on-screen readout of magnitude and amps
    • Reduces measurement errors with no more hand calculations
  • AC/DC input coupling
  • Low insertion impedance reduces DUT loading
  • Split-core design allows easy circuit connection
  • Status Indicators provide visual operating status and notification of potential error conditions including:
    • Degauss, Probe open, Overload, Not terminated into 50 Ω, Noncompatible probe type
  • Lower DC drift and noise allows improved low-level cur measurements
  • Complies with IEC standards
  • Applications:
    • Development and analysis solutions for designers, installers, and service personnel in Telecomm, Data Comm, computer, and semiconductor power electronics environments for:
      • Power supplies (switching and linear)
      • Semiconductor devices (SCRs, IGBTs, MOSFETs, CMOS, BJTs)
      • Power Inverters/Converters
      • Electronic ballasts
      • Industrial/Consumer electronics
      • Mobile communications (phone, satellite, relay stations)
      • Motor drives
      • Transportation systems (electronic vehicles and trains, locomotives, avionics)
  • Requires a TDS TEKPROBE Oscilloscope or a TekConnect oscilliscope with TCA-BNC
  • Oscilloscope on-screen readout of magnitude and amps
  • Reduces measurement errors with no more hand calculations
  • Degauss, Probe open, Overload, Not terminated into 50 Ω, Noncompatible probe type
  • Development and analysis solutions for designers, installers, and service personnel in Telecomm, Data Comm, computer, and semiconductor power electronics environments for:
    • Power supplies (switching and linear)
    • Semiconductor devices (SCRs, IGBTs, MOSFETs, CMOS, BJTs)
    • Power Inverters/Converters
    • Electronic ballasts
    • Industrial/Consumer electronics
    • Mobile communications (phone, satellite, relay stations)
    • Motor drives
    • Transportation systems (electronic vehicles and trains, locomotives, avionics)
  • Power supplies (switching and linear)
  • Semiconductor devices (SCRs, IGBTs, MOSFETs, CMOS, BJTs)
  • Power Inverters/Converters
  • Electronic ballasts
  • Industrial/Consumer electronics
  • Mobile communications (phone, satellite, relay stations)
  • Motor drives
  • Transportation systems (electronic vehicles and trains, locomotives, avionics)
  • Characteristic:
    • Bandwidth (-3 dB):  DC - 50 MHz
    • Rise Time:  ≤7 ns
    • Maximum Cur Ratings: 
      • High-cur Sensitivity Range: 10 A/V Range:
        • DC (continuous):  50 A
        • RMS (sinusoidal):  35.4 A
        • Peak Pulse:  50 A
      • Low-cur Sensitivity Range:  5 A/V Range:
        • DC (continuous):  25 A
        • RMS (sinusoidal):  17.7 A
        • Peak Pulse:  50 A
    • DC Accuracy (operating temp 0 °C to 50 °C):  ±3% of reading
    • DC Accuracy, typical (operating temp 23 °C ±5 °C):  ±1% of reading
  • Nominal:
    • Maximum Bare Wire Voltage:  For use with insulated wires only
    • Lowest Measurable Cur (at ±3% accuracy at DC):
      • 5 mA
      • Scope set to 1 mV/div and 20 MHz BW limited
    • Insertion Impedance:
      • 0.035 Ω at 1 MHz
      • 0.12 Ω at 10 MHz
      • 0.4 Ω at 50 MHz
  • Typical:
    • Maximum Amp-Second Product (based on amplifier range setting):
      • 500 AμS – 5 A/V
      • NA - 10 A/V
    • AC-coupling Low-frequency Bandwidth (Low Pass – 3 dB point): 
    • Displayed RMS Noise (at 20 MHz bandwidth limit):  ≤1.25 mARMS
    • Signal Delay (delay to output BNC):  19 ns
    • Probe Amplifier Inputs:  1
    • Probe Open Indicator:  Yes
    • Overload Indicator:  Yes
    • Termination Indicator:  Yes
    • Noncompatible Probe Indicator:  Yes
  • Bandwidth (-3 dB):  DC - 50 MHz
  • Rise Time:  ≤7 ns
  • Maximum Cur Ratings: 
    • High-cur Sensitivity Range: 10 A/V Range:
      • DC (continuous):  50 A
      • RMS (sinusoidal):  35.4 A
      • Peak Pulse:  50 A
    • Low-cur Sensitivity Range:  5 A/V Range:
      • DC (continuous):  25 A
      • RMS (sinusoidal):  17.7 A
      • Peak Pulse:  50 A
  • DC Accuracy (operating temp 0 °C to 50 °C):  ±3% of reading
  • DC Accuracy, typical (operating temp 23 °C ±5 °C):  ±1% of reading
  • High-cur Sensitivity Range: 10 A/V Range:
    • DC (continuous):  50 A
    • RMS (sinusoidal):  35.4 A
    • Peak Pulse:  50 A
  • Low-cur Sensitivity Range:  5 A/V Range:
    • DC (continuous):  25 A
    • RMS (sinusoidal):  17.7 A
    • Peak Pulse:  50 A
  • DC (continuous):  50 A
  • RMS (sinusoidal):  35.4 A
  • Peak Pulse:  50 A
  • DC (continuous):  25 A
  • RMS (sinusoidal):  17.7 A
  • Peak Pulse:  50 A
  • Maximum Bare Wire Voltage:  For use with insulated wires only
  • Lowest Measurable Cur (at ±3% accuracy at DC):
    • 5 mA
    • Scope set to 1 mV/div and 20 MHz BW limited
  • Insertion Impedance:
    • 0.035 Ω at 1 MHz
    • 0.12 Ω at 10 MHz
    • 0.4 Ω at 50 MHz
  • 5 mA
  • Scope set to 1 mV/div and 20 MHz BW limited
  • 0.035 Ω at 1 MHz
  • 0.12 Ω at 10 MHz
  • 0.4 Ω at 50 MHz
  • Maximum Amp-Second Product (based on amplifier range setting):
    • 500 AμS – 5 A/V
    • NA - 10 A/V
  • AC-coupling Low-frequency Bandwidth (Low Pass – 3 dB point): 
  • Displayed RMS Noise (at 20 MHz bandwidth limit):  ≤1.25 mARMS
  • Signal Delay (delay to output BNC):  19 ns
  • Probe Amplifier Inputs:  1
  • Probe Open Indicator:  Yes
  • Overload Indicator:  Yes
  • Termination Indicator:  Yes
  • Noncompatible Probe Indicator:  Yes
  • 500 AμS – 5 A/V
  • NA - 10 A/V
  •     
  • No Options Included
  • MSRP: $1,840 | In Stock!      
  •     

    No Related Posts

    Devoluciones

    Si no estás completamente satisfecho con tu compra, simplemente devuelve el artículo en su estado original dentro de los 30 días posteriores a la recepción. Los artículos devueltos deben estar sin usar y en su embalaje original, junto con toda la documentación incluida. Emitiremos un reembolso completo al recibir el artículo, excluyendo el coste original del envío. Alternativamente, si lo prefieres, podemos cambiar el artículo.