Tektronix TDP3500

FabricanteTektronix
ModeloTDP3500
ProductoDifferential Probe, 3.5 GHz
TipoUsado

 

Tektronix TDP1500

Tektronix TDP1500

Tektronix TDS2001C

Tektronix TDS2001C

Obtener cotización
SKU
143808
Tektronix TDP3500 Diffeial Probe, 1.5 GHzThe Tektronix TDP3500 Probe is a Diffeial-ended Active probe that provides truer signal reproduction and fidelity for high-frequency measurements. It also provides high-speed electrical and mechanical performance required for today's digital system designs. The Tektronix TDP3500 Probe is designed specifically for use, and direct connection to, Tektronix Oscilloscopes with the TekVPI™ probe interface.Features and Specifications of the TDP3500 Diffeial Probe include:
  • Features:
    • Outstanding electrical performance:
      • Bandwidth that provides accurate measurements for serial and digital applications
      • Excellent common mode rejection that reduces measurement errors in higher common environments
      • Low capacitive and resistive loading:
        • Maintains signal fidelity
        • Reduces DC biasing interactions
    • Versatile mechanical performance:
      • Compact probe head size for probing small geometry circuit elements
      • DUT attachment accessories enable connection to fine-spaced SMDs
      • Robust design for reliability
    • Connects directly to Oscilloscope with the TekVPI™ probe interface
    • Provides automatic units scaling and readout on the Oscilloscope display
    • Embeds the probe characteristics within the Oscilloscope
    • Easy access to probe comp box controls or Oscilloscope probe menu display for:
      • probe status
      • probe setup control
      • diagnostic information
    • Integrated Scope/Probe System:
      • Direct connection to and powered from the TekVPI™ Oscilloscope Interface without the need of an external power supply
      • Single-button Oscilloscope probe menu access
      • Setup and control from comp box or Oscilloscope user interface
      • AutoZero:  Zeros out output offset
      • Remote GPIB/USB probe control through the Oscilloscope
    • Applications:
      • Design, validation, degugging, and characterization of common high-speed serial bus designs:
        • I2C
        • CAN/LIN
        • SPI
        • Serial ATA
        • Ethernet (GbE)
        • USB 2.0
        • Firewire (1394b)
      • Signal integrity, jitter, and timing analysis
      • Manufacturing, engineering and test
  • Specifications:
    • Probe Bandwidth:  ≥3.5 GHz warranted
    • Probe Attenuation:  5x
    • Probe Rise Time:  ≤110 ps typical
    • Diffeial Input Capacitance:  ≤0.3 pF
    • Diffeial Input Resistance:  100 kΩ
    • Diffeial Input Dynamic Range:  ±2 V
    • CMRR:
      • >60 dB at 1 MHz
      • >25 dB at 1 GHz
    • Input Offset Range: ±1 V displayed
    • Operation Voltage Input Range (Common Mode Input Range):  +5 V to -4V
    • Noise:  ≈35 nV/root Hz
    • Max Input Voltage (Nondestruct):  ±15 V (DC + pk AC)
    • Propagation Delay:  5.4 ns typical
  • Outstanding electrical performance:
    • Bandwidth that provides accurate measurements for serial and digital applications
    • Excellent common mode rejection that reduces measurement errors in higher common environments
    • Low capacitive and resistive loading:
      • Maintains signal fidelity
      • Reduces DC biasing interactions
  • Versatile mechanical performance:
    • Compact probe head size for probing small geometry circuit elements
    • DUT attachment accessories enable connection to fine-spaced SMDs
    • Robust design for reliability
  • Connects directly to Oscilloscope with the TekVPI™ probe interface
  • Provides automatic units scaling and readout on the Oscilloscope display
  • Embeds the probe characteristics within the Oscilloscope
  • Easy access to probe comp box controls or Oscilloscope probe menu display for:
    • probe status
    • probe setup control
    • diagnostic information
  • Integrated Scope/Probe System:
    • Direct connection to and powered from the TekVPI™ Oscilloscope Interface without the need of an external power supply
    • Single-button Oscilloscope probe menu access
    • Setup and control from comp box or Oscilloscope user interface
    • AutoZero:  Zeros out output offset
    • Remote GPIB/USB probe control through the Oscilloscope
  • Applications:
    • Design, validation, degugging, and characterization of common high-speed serial bus designs:
      • I2C
      • CAN/LIN
      • SPI
      • Serial ATA
      • Ethernet (GbE)
      • USB 2.0
      • Firewire (1394b)
    • Signal integrity, jitter, and timing analysis
    • Manufacturing, engineering and test
  • Bandwidth that provides accurate measurements for serial and digital applications
  • Excellent common mode rejection that reduces measurement errors in higher common environments
  • Low capacitive and resistive loading:
    • Maintains signal fidelity
    • Reduces DC biasing interactions
  • Maintains signal fidelity
  • Reduces DC biasing interactions
  • Compact probe head size for probing small geometry circuit elements
  • DUT attachment accessories enable connection to fine-spaced SMDs
  • Robust design for reliability
  • probe status
  • probe setup control
  • diagnostic information
  • Direct connection to and powered from the TekVPI™ Oscilloscope Interface without the need of an external power supply
  • Single-button Oscilloscope probe menu access
  • Setup and control from comp box or Oscilloscope user interface
  • AutoZero:  Zeros out output offset
  • Remote GPIB/USB probe control through the Oscilloscope
  • Design, validation, degugging, and characterization of common high-speed serial bus designs:
    • I2C
    • CAN/LIN
    • SPI
    • Serial ATA
    • Ethernet (GbE)
    • USB 2.0
    • Firewire (1394b)
  • Signal integrity, jitter, and timing analysis
  • Manufacturing, engineering and test
  • I2C
  • CAN/LIN
  • SPI
  • Serial ATA
  • Ethernet (GbE)
  • USB 2.0
  • Firewire (1394b)
  • Probe Bandwidth:  ≥3.5 GHz warranted
  • Probe Attenuation:  5x
  • Probe Rise Time:  ≤110 ps typical
  • Diffeial Input Capacitance:  ≤0.3 pF
  • Diffeial Input Resistance:  100 kΩ
  • Diffeial Input Dynamic Range:  ±2 V
  • CMRR:
    • >60 dB at 1 MHz
    • >25 dB at 1 GHz
  • Input Offset Range: ±1 V displayed
  • Operation Voltage Input Range (Common Mode Input Range):  +5 V to -4V
  • Noise:  ≈35 nV/root Hz
  • Max Input Voltage (Nondestruct):  ±15 V (DC + pk AC)
  • Propagation Delay:  5.4 ns typical
  • >60 dB at 1 MHz
  • >25 dB at 1 GHz
  •       

    No Related Posts

    Devoluciones

    Si no estás completamente satisfecho con tu compra, simplemente devuelve el artículo en su estado original dentro de los 30 días posteriores a la recepción. Los artículos devueltos deben estar sin usar y en su embalaje original, junto con toda la documentación incluida. Emitiremos un reembolso completo al recibir el artículo, excluyendo el coste original del envío. Alternativamente, si lo prefieres, podemos cambiar el artículo.

    IVA

    Los precios no incluyen IVA. Transacciones intracomunitarias: Según la Directiva del IVA de la UE, las ventas B2B de bienes dentro de la UE están exentas de IVA. Cuando se aplica el IVA, se utiliza una tasa del 23%. Fuera de la UE no se aplica IVA.

    Clicky