The store will not work correctly when cookies are disabled.
JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Yokogawa WT310HC Fabricante Yokogawa Modelo WT310HC Producto Digital Power Meter, DC - 20 kHz, 40A, 1 Ch. Type Used
Yokogawa WT3000E Yokogawa WT332 Garantía de hasta 12 meses
Extensión de garantía opcional hasta 24 mese
Derecho de devolución de 30 días
Certificado de Conformidad
YOKOGAWA WT310HC Digital Power Meter (call for availability )The Yokogawa WT310HC Digital Power Meter provides a wide cur input range, fast display, and rapid data update rate in a compact and powerful instrument. High performance and reliable power measurement make it the preferred power meter in numerous industries from production lines to R&D applications. Features and Specifications of the Yokogawa WT310HC Digital Power Meter include: Features: High Performance and Reliability: Basic accuracy of 0.1% of reading Low cur measurement Wide cur input ranges Standard USB, and GP-IB or RS-232 (selectable) and Ethernet (optional) Simultaneous Measurement of All Parameters: Measures all AC and DC parameters Measures harmonics and performs integration simultaneously without changing the measurement mode Uses WTViewrFreePlus software to monitor and save parameters Fast Display and Data Update Rate: Provides short tact time in testing procedures Consistent basic measurement accuracy for all input ranges Convenient Measurement Functions: MAX Hold Function: Allows maximum values of RMS/PEAK voltage and cur active power, reactive power and appa power to be held Line Filter and Frequency Filter Functions: Cuts off unnecessary noise and harmonic components for fundamental waveform measurements Specifications: Input Elements: 1 Input Terminal Type: Voltage: Plug-in terminal (safety terminal) Cur: Direct input: Large binding post Input Format: Voltage: Floating input through resistive voltage divider Cur: Floating input through shunt Measurement Range: Voltage: Crest factor 3: 15V/30V/60V/150V/300V/600V Crest factor 6: 7.5V/15V/30V/75V/150V/300V Cur: Direct input: Crest factor 3: 5mA/10mA/20mA/50mA/100mA/200mA/0.5A/1A/2A/5A/10A/20A Crest factor 6: 2.5mA/5mA/10mA/25mA/50mA/100mA/0.25A/0.5A/1A/2.5A/5A/10A External cur sensor input (/EX1,/EX2): Crest factor 3: EX1: 2.5V/5V/10V EX2: 50mV/100mV/200mV/500mV/1V/2V Crest factor 6: EX1: 1.25V/2.5V/5V EX2: 25mV/50mV/100mV/250mV/500mV/1V Input Impedance: Voltage: Input resistance: Approx. 2 MΩ Input capacitance: Approx. 13 pF in parallel with the resistance Cur: Direct input: Crest factor 3: 5mA/10mA/20mA/50mA/100mA/200mA Crest factor 6: 2.5mA/5mA/10mA/25mA/50mA/100mA At the above range setting: Input resistance: Approx. 500mΩ, Input inductance: Approx. 1uH in serieswith the resistance Crest factor 3: 0.5A/1A/2A/5A/10A/20A Crest factor 6: 0.25A/0.5A/1A/2.5A/5A/10A At the above range setting: Input resistance: Approx. 6 mΩ + 10 mΩ max)*Factory setting Input inductance: Approx. 0.1uH in series with the resistance General Specifications: Rated supply voltage: 100 VAC to 240 VAC Permitted supply range voltage: 90 VAC to 264 VAC Rated supply frequency: 50/60 Hz Permitted supply voltage frequency range: 48 Hz to 63 Hz Maximum power consumption: 50VA Battery backup: Setup parameters are backed up with a lithium battery High Performance and Reliability: Basic accuracy of 0.1% of reading Low cur measurement Wide cur input ranges Standard USB, and GP-IB or RS-232 (selectable) and Ethernet (optional) Simultaneous Measurement of All Parameters: Measures all AC and DC parameters Measures harmonics and performs integration simultaneously without changing the measurement mode Uses WTViewrFreePlus software to monitor and save parameters Fast Display and Data Update Rate: Provides short tact time in testing procedures Consistent basic measurement accuracy for all input ranges Convenient Measurement Functions: MAX Hold Function: Allows maximum values of RMS/PEAK voltage and cur active power, reactive power and appa power to be held Line Filter and Frequency Filter Functions: Cuts off unnecessary noise and harmonic components for fundamental waveform measurements Basic accuracy of 0.1% of reading Low cur measurement Wide cur input ranges Standard USB, and GP-IB or RS-232 (selectable) and Ethernet (optional) Measures all AC and DC parameters Measures harmonics and performs integration simultaneously without changing the measurement mode Uses WTViewrFreePlus software to monitor and save parameters Provides short tact time in testing procedures Consistent basic measurement accuracy for all input ranges MAX Hold Function: Allows maximum values of RMS/PEAK voltage and cur active power, reactive power and appa power to be held Line Filter and Frequency Filter Functions: Cuts off unnecessary noise and harmonic components for fundamental waveform measurements Input Elements: 1 Input Terminal Type: Voltage: Plug-in terminal (safety terminal) Cur: Direct input: Large binding post Input Format: Voltage: Floating input through resistive voltage divider Cur: Floating input through shunt Measurement Range: Voltage: Crest factor 3: 15V/30V/60V/150V/300V/600V Crest factor 6: 7.5V/15V/30V/75V/150V/300V Cur: Direct input: Crest factor 3: 5mA/10mA/20mA/50mA/100mA/200mA/0.5A/1A/2A/5A/10A/20A Crest factor 6: 2.5mA/5mA/10mA/25mA/50mA/100mA/0.25A/0.5A/1A/2.5A/5A/10A External cur sensor input (/EX1,/EX2): Crest factor 3: EX1: 2.5V/5V/10V EX2: 50mV/100mV/200mV/500mV/1V/2V Crest factor 6: EX1: 1.25V/2.5V/5V EX2: 25mV/50mV/100mV/250mV/500mV/1V Input Impedance: Voltage: Input resistance: Approx. 2 MΩ Input capacitance: Approx. 13 pF in parallel with the resistance Cur: Direct input: Crest factor 3: 5mA/10mA/20mA/50mA/100mA/200mA Crest factor 6: 2.5mA/5mA/10mA/25mA/50mA/100mA At the above range setting: Input resistance: Approx. 500mΩ, Input inductance: Approx. 1uH in serieswith the resistance Crest factor 3: 0.5A/1A/2A/5A/10A/20A Crest factor 6: 0.25A/0.5A/1A/2.5A/5A/10A At the above range setting: Input resistance: Approx. 6 mΩ + 10 mΩ max)*Factory setting Input inductance: Approx. 0.1uH in series with the resistance General Specifications: Rated supply voltage: 100 VAC to 240 VAC Permitted supply range voltage: 90 VAC to 264 VAC Rated supply frequency: 50/60 Hz Permitted supply voltage frequency range: 48 Hz to 63 Hz Maximum power consumption: 50VA Battery backup: Setup parameters are backed up with a lithium battery Voltage: Plug-in terminal (safety terminal) Cur: Direct input: Large binding post Voltage: Floating input through resistive voltage divider Cur: Floating input through shunt Voltage: Crest factor 3: 15V/30V/60V/150V/300V/600V Crest factor 6: 7.5V/15V/30V/75V/150V/300V Cur: Direct input: Crest factor 3: 5mA/10mA/20mA/50mA/100mA/200mA/0.5A/1A/2A/5A/10A/20A Crest factor 6: 2.5mA/5mA/10mA/25mA/50mA/100mA/0.25A/0.5A/1A/2.5A/5A/10A External cur sensor input (/EX1,/EX2): Crest factor 3: EX1: 2.5V/5V/10V EX2: 50mV/100mV/200mV/500mV/1V/2V Crest factor 6: EX1: 1.25V/2.5V/5V EX2: 25mV/50mV/100mV/250mV/500mV/1V Crest factor 3: 15V/30V/60V/150V/300V/600V Crest factor 6: 7.5V/15V/30V/75V/150V/300V Direct input: Crest factor 3: 5mA/10mA/20mA/50mA/100mA/200mA/0.5A/1A/2A/5A/10A/20A Crest factor 6: 2.5mA/5mA/10mA/25mA/50mA/100mA/0.25A/0.5A/1A/2.5A/5A/10A External cur sensor input (/EX1,/EX2): Crest factor 3: EX1: 2.5V/5V/10V EX2: 50mV/100mV/200mV/500mV/1V/2V Crest factor 6: EX1: 1.25V/2.5V/5V EX2: 25mV/50mV/100mV/250mV/500mV/1V Crest factor 3: 5mA/10mA/20mA/50mA/100mA/200mA/0.5A/1A/2A/5A/10A/20A Crest factor 6: 2.5mA/5mA/10mA/25mA/50mA/100mA/0.25A/0.5A/1A/2.5A/5A/10A Crest factor 3: EX1: 2.5V/5V/10V EX2: 50mV/100mV/200mV/500mV/1V/2V Crest factor 6: EX1: 1.25V/2.5V/5V EX2: 25mV/50mV/100mV/250mV/500mV/1V EX1: 2.5V/5V/10V EX2: 50mV/100mV/200mV/500mV/1V/2V EX1: 1.25V/2.5V/5V EX2: 25mV/50mV/100mV/250mV/500mV/1V Voltage: Input resistance: Approx. 2 MΩ Input capacitance: Approx. 13 pF in parallel with the resistance Cur: Direct input: Crest factor 3: 5mA/10mA/20mA/50mA/100mA/200mA Crest factor 6: 2.5mA/5mA/10mA/25mA/50mA/100mA At the above range setting: Input resistance: Approx. 500mΩ, Input inductance: Approx. 1uH in serieswith the resistance Crest factor 3: 0.5A/1A/2A/5A/10A/20A Crest factor 6: 0.25A/0.5A/1A/2.5A/5A/10A At the above range setting: Input resistance: Approx. 6 mΩ + 10 mΩ max)*Factory setting Input inductance: Approx. 0.1uH in series with the resistance Input resistance: Approx. 2 MΩ Input capacitance: Approx. 13 pF in parallel with the resistance Direct input: Crest factor 3: 5mA/10mA/20mA/50mA/100mA/200mA Crest factor 6: 2.5mA/5mA/10mA/25mA/50mA/100mA At the above range setting: Input resistance: Approx. 500mΩ, <span id="MainContent_F
Devoluciones
Si no estás completamente satisfecho con tu compra, simplemente devuelve el artículo en su estado original dentro de los 30 días posteriores a la recepción.
Los artículos devueltos deben estar sin usar y en su embalaje original, junto con toda la documentación incluida. Emitiremos un reembolso completo al recibir el artículo, excluyendo el coste original del envío. Alternativamente, si lo prefieres, podemos cambiar el artículo.
IVA
Los precios no incluyen IVA.
Transacciones intracomunitarias: Según la Directiva del IVA de la UE, las ventas B2B de bienes dentro de la UE están exentas de IVA.
Cuando se aplica el IVA, se utiliza una tasa del 23%.
Fuera de la UE no se aplica IVA.
Get a Quote for