Fluke

Fluke 773

Milliamp Process Clamp Meter
4 mA à 20 mA Plage de mesure du courant en boucle
±0,2% + 2 chiffres Précision de mesure
24 V CC Alimentation de la boucle
1000 Ω Résistance maximale de la boucle
Écran LCD double affichage Affichage
Demander la fiche technique
Attribut Valeur
Plage de mesure du courant en boucle 4 mA à 20 mA
Précision de mesure ±0,2% + 2 chiffres
Alimentation de la boucle 24 V CC
Résistance maximale de la boucle 1000 Ω
Affichage Écran LCD double affichage
Simulation de courant Sortie de simulation 4-20 mA réglable
Alimentation de l'appareil 2 piles AA 1,5 V
Catégorie de sécurité CAT III 600 V / CAT IV 300 V
Dimensions 190 mm x 86 mm x 46 mm
Poids 340 g (avec piles)
Formulaire d'étalonnage Fluke 773

Formulaire de réparation Fluke 773
Maximum file size: 40MB

No Related Posts

Plus d'informations
Model773

 FLUKE  773 Milliamp Process Clamp Meter

 

The Fluke 773 Milliamp Process Clamp Meter  is a accurate, versatile, and highly portable tool, designed  saves time and money by measuring 4 €“20 mA signals five times faster than with traditional multimeters, and without breaking the loop. That means you can troubleshoot a live device without having to power down and possibly miss something going on in the process.  Fluke 773 Milliamp Process Clamp Meter features the unique mA scale to measure a mA signal without breaking the loop and output that signal to another device to record the measurements.

The Fluke  773 Milliamp Process Clamp Meter is ideal for troubleshooting transmitters, valves, and programmable logic controllers (PLCs) found in process plants. The 773 allows you to connect to a mA loop in a traditional series workflow to measure, source, or simulate a control system. And it measures up to 99.0 mA non-contact, including 10 to 50 mA signals in older control systems.  Fluke 773 Milliamp Process Clamp Meter  also sources and measures DC voltage, so it can be used to troubleshoot voltage input and output devices that accept a 1-5 V or 0 to 10 V signal. You can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces.

 

Specifications for the  FLUKE  773 Milliamp Process Clamp Meter Include:

mA measurement range  (Measured by Clamp) 0 to 20.99 mA,  21.0 to 100.0 mA
Accuracy  (Measured by Clamp) 0.2% + 5 counts,  1 % + 5 counts
Diameter of measurable conductor 0.177" or 4.5 mm max
Operating temperature -10 to 50 ºC

 

Clicky Copyright © 2013-present Magento, Inc. All rights reserved.