Keysight (Agilent)

Keysight (Agilent) N7788B

Optical Component Analyzer
1260 nm à 1640 nm Plage de longueur d'onde
±0,1 pm Précision de la longueur d'onde
0,01 pm Résolution de la longueur d'onde
0 dB à 100 dB Plage de mesure de la perte d'insertion
±0,01 dB Précision de la puissance
Demander la fiche technique
Attribut Valeur
Plage de longueur d'onde 1260 nm à 1640 nm
Précision de la longueur d'onde ±0,1 pm
Résolution de la longueur d'onde 0,01 pm
Plage de mesure de la perte d'insertion 0 dB à 100 dB
Précision de la puissance ±0,01 dB
Interface de communication GPIB, USB, LAN (LXI)
Vitesse de balayage maximale 100 nm/s
Nombre de voies de détection Jusqu'à 4 voies simultanées
Plage de puissance d'entrée -80 dBm à +10 dBm
Alimentation électrique 100-240 V CA, 50/60 Hz
Keysight (Agilent) N7788B Options:
  • N7788B - 021 - Straight contact connector (Laser input port)
  • N7788B - 022 - Angled contact connector (Laser input port)
  • N7788B - 031 - Straight contact connector (DUT ports)
  • N7788B - 032 - Angled contact connector (DUT ports)
  • N7788B - 300 - Wavelength range 1270 to 1375 nm (O-Band)
  • N7788B - 400 - Wavelength range 1270 to 1375 nm and 1460 to 1620 nm (O/C/L-Band)
  • N7788B - 500 - Wavelength range 1460 to 1620 nm (C/L-Band)
  • N7788B - R-51B-001-5Z - 5-year warranty assurance plan (return to Keysight); priority warranty service includes one-time coverage for an EOS/ESD failure
  • N7788B - R-50C-011-3 - 3-year calibration assurance plan (return to Keysight); 15% cheaper than buying stand-alone calibrations
  • N7788B - R-50C-011-5 - 5-year calibration assurance plan (return to Keysight); 20% cheaper than buying stand-alone calibrations
Formulaire d'étalonnage Keysight (Agilent) N7788B

Formulaire de réparation Keysight (Agilent) N7788B
Maximum file size: 40MB

KEYSIGHT N7788B

The Keysight N7788B Component Analyzer uses proprietary technology to push the limits of today's optical technology. The Keysight N7788B  is comparable with the well-known Jones-Matrix-Eigenanalysis (JME) which is the standard method for measuring Polarization Mode Dispersion (PMD) or differential group delay (DGD) of optical devices.

The new  single scan technology from Keysight, offers a range of advantages to test a complete set of parameters including:

  • DGD/ PMD
  • PDL
  • Power / Loss
  • TE / TM-Loss
  • 2nd-order PMD
  • Principal States of Polarization (PSPs)
  • Jones and Mueller Matrices

Features of the N7788B  Optical Component Analyzer include:

  • High throughput: A complete analysis across the C and the L band is performed in less than 10 seconds
  • Software Drivers: A range of software drivers is available for external control of the system. This allows easy integration in common ERP systems.
  • Remote control: Control of the instrument through LAN or via the Internet is supported. This supports automation as well as trouble shooting.
  • Report Generation: Generating PDF reports is supported. The content including layout is configurable by the user.
  • Real time power readout: High throughput measurement of non-connectorized components is supported by providing a real time power readout which enables fiber coupling of the new device.
  • Barcode Scanner: Using Barcode scanner is supported for quick transfer of the DUT serial number.

Specifications of the Keysight N7788B include:

Wavelength (must select appropriate option at time of order):

  • 1270 nm to 1375 nm (Opt. 300, O-Band)
  • 1270 nm to 1375 nm, 1460 nm to 1620 nm (Opt. 400, O/C/L-Band)
  • 1460 nm to 1620 nm (Opt. 500, C/L-Band)
  • Operating wavelength range: 1260 nm to 1640 nm (SOP/DOP measurements are only possible outside the specification wavelength range if the user performs a manual calibration).

Differential group delay

  • DGD uncertainty
    • Resolution 2.0 nm ± (30 fs + 3.0% * DGD)
    • Resolution 0.1 nm ± (30 fs + 3.0% * DGD)
  • DGD measurement range 0 ps to 1000 ps
  • PMD uncertainty ± (30 fs + 2.0% * DGD)
  • PMD repeatability (typical) ± 3 fs
  • PMD measurement range 0 ps to 300 ps

Loss

  • PDL uncertainty
    • 5 C-Band ± (0.05 dB + 4% * PDL)
    • O-Band ± (0.10 dB + 4% * PDL)
  • PDL repeatability (typical) ± 0.005 dB
  • Insertion loss uncertainty (typical)
    • C/L-Band ± 0.03 dB
    • O-Band ± 0.07 dB
  • Insertion loss dynamic range (typical) > 41 dB (for higher TLS power levels, increase value accordingly)

Polarization analysis

  • SOP uncertainty (typical) 1.5 °
  • DOP uncertainty ± 2.0 %
  • DOP uncertainty after user calibration (typical) ± 0.5 %
  • Maximum sampling rate 1 MHz

Optical power measurement

  • Relative power uncertainty
    • C/L-Band: ± -.03 dB ( ± 0.02 dB typical)
    • O-Band: ± 0.07 dB ( ± 0.04 dB typical)
  • Input power range -50 dBm to +7 dBm
  • Maximum safe optical input power +12 dBm

Polarization control

  • SOP switching time < 10 μs
  • PDL (typical)
    • C/L-Band < 0.2 dB
    • O-Band < 0.5 dB
  • Insertion loss < 3.5 dB (< 3 dB, typical)
  • Maximum safe input power +20 dBm