Keysight (Agilent) MSOX4024A

| Attribut | Valeur |
|---|---|
| Bande passante | 200 MHz |
| Nombre de voies analogiques | 4 |
| Nombre de voies numériques | 16 |
| Taux d'échantillonnage maximum | 5 GSa/s |
| Profondeur mémoire | 4 Mpts (standard), 8 Mpts (optionnel) |
| Taille de l'écran | 8,5 pouces WVGA (800 x 480 pixels) |
| Résolution verticale | 8 bits |
| Taux de rafraîchissement de la forme d'onde | 1 000 000 formes d'onde par seconde |
| Sensibilité verticale | 1 mV/div à 5 V/div |
| Interfaces de connectivité | USB, LAN (LXI), GPIB (optionnel) |
Keysight (Agilent) MSOX4024A Options:
- MSOX4024A - DSOX4EMBD - Embedded serial triggering and decode (I²C, SPI)
- MSOX4024A - DSOX4COMP - Computer serial triggering and decode (RS232/UART)
- MSOX4024A - DSOX4USBFL - USB 2.0 Full/Low Speed serial triggering and decode
- MSOX4024A - DSOX4USBH - USB 2.0 Hi-Speed serial triggering and decode (1 GHz and 1.5 GHz models only)
- MSOX4024A - DSOX4AUTO - Automotive serial triggering and decode (CAN/CAN-dbc/LIN)
- MSOX4024A - DSOX4FLEX - FlexRay serial triggering and decode
- MSOX4024A - DSOX4AUDIO - Audio serial triggering and decode (I²S)
- MSOX4024A - DSOX4AERO - Aerospace and defence serial triggering and decode (MIL-STD 1553, ARINC 429)
- MSOX4024A - DSOX4WAVEGEN2 - Dual-channel WaveGen 20 MHz arbitrary/function generator
- MSOX4024A - DSOXDVM - 3-digit voltmeter (DVM)
- MSOX4024A - DSOX4PWR - Power analysis application
- MSOX4024A - DSOX4MASK - Mask limit testing
- MSOX4024A - DSOX4VID - Enhanced video/TV application package
- MSOX4024A - DSOX4FPGAX - FPGA dynamic probe option for Xilinx
- MSOX4024A - DSOX4USBSQ - USB 2.0 signal quality test option
- MSOX4024A - DSOXEDK - Education training kit
- MSOX4024A - DSOXPERFMSO - 4000 X-Series oscilloscope MSO upgrade
- MSOX4024A - DSOX4B3T52U - Bandwidth upgrade 350 MHz to 500 MHz, 2 ch (License Only)
- MSOX4024A - DSOX4B3T54U - Bandwidth upgrade 350 MHz to 500 MHz, 4 ch (License Only)
- MSOX4024A - DSOX4B2T32U - Bandwidth upgrade 200 MHz to 350 MHz, 2 ch (Service Center)
- MSOX4024A - DSOX4B2T34U - Bandwidth upgrade 200 MHz to 350 MHz, 4 ch (Service Center)
- MSOX4024A - DSOX4B5T104U - Bandwidth upgrade 500 MHz to 1 GHz, 4 ch (Service Center)
- MSOX4024A - DSOX4B1T154U - Bandwidth upgrade 1 GHz to 1.5 GHz, 4 ch (Service Center)
- MSOX4024A - DSOX4B2T52U - Bandwidth upgrade 200 MHz to 500 MHz, 2 ch (Service Center)
- MSOX4024A - DSOX4B2T54U - Bandwidth upgrade 200 MHz to 500 MHz, 4 ch (Service Center)
- MSOX4024A - DSOX4B2T104U - Bandwidth upgrade 200 MHz to 1 GHz, 4 ch (Service Center)
- MSOX4024A - DSOX4B2T154U - Bandwidth upgrade 200 MHz to 1.5 GHz, 4 ch (Service Center)
- MSOX4024A - DSOX4B3T104U - Bandwidth upgrade 350 MHz to 1 GHz, 4 ch (Service Center)
- MSOX4024A - DSOX4B3T154U - Bandwidth upgrade 350 MHz to 1.5 GHz, 4 ch (Service Center)
- MSOX4024A - DSOX4B5T154U - Bandwidth upgrade 500 MHz to 1.5 GHz, 4 ch (Service Center)
| Model | MSOX4024A |
|---|
L’oscilloscope Keysight (Agilent) MSOX4024A offre une bande passante de 200 MHz, 4 canaux analogiques et 16 numériques, ainsi qu’un écran tactile capacitif de 12,1 pouces. Avec un taux de rafraîchissement de 1 000 000 wfms/s et la mémoire intelligente MegaZoom IV, il fournit une visibilité détaillée des formes d’onde. Le déclenchement par zone tactile et la mémoire segmentée de 4 Mpts permettent une analyse rapide et approfondie du signal.
Entièrement évolutif avec des options telles que générateur d’ondes, DVM, analyse série et test par masque, il est idéal pour le débogage avancé et la validation de conception dans les domaines de l’électronique.
Testwall peut fournir le Keysight (Agilent) MSOX4024A d’occasion, entièrement testé. Avec un support expert et une livraison mondiale, Testwall garantit des instruments de haute performance avec une fiabilité et une qualité de service inégalées. Veuillez nous contacter directement si vous avez besoin d’étalonnage ou de réparation du Keysight (Agilent) MSOX4024A.