Sorensen IB-1-1000-100-1000

| Attribut | Valeur |
|---|---|
| Tension de sortie | 0 – 1000 V |
| Courant de sortie | 0 – 1 A |
| Puissance de sortie | 1000 W |
| Tension d'entrée | 208/240 V CA, monophasé |
| Régulation de tension en charge | ≤ 0,05 % + 5 mV |
| Régulation de courant en charge | ≤ 0,05 % + 1 mA |
| Ondulation et bruit (tension) | ≤ 100 mV crête à crête |
| Ondulation et bruit (courant) | ≤ 100 mA crête à crête |
| Interface de programmation | Analogique 0 – 5 V / 0 – 10 V |
| Format mécanique | Rack 19 pouces, 1U |
Sorensen IB-1-1000-100-1000 Options:
- IB-1-1000-100-1000 - IB-CAB-USA-100 - UL-489 Compliant Cabinet, 100kW Version USA / Canada
- IB-1-1000-100-1000 - IB-CAB-USA-160 - UL-489 Compliant Cabinet, 160kW Version USA / Canada
- IB-1-1000-100-1000 - IB-CAB-USA-250 - UL-489 Compliant Cabinet, 250kW Version USA / Canada
- IB-1-1000-100-1000 - IB-CAB-USA-320 - UL-489 Compliant Cabinet, 320kW Version USA / Canada
- IB-1-1000-100-1000 - IB-CAB-USA-400 - UL-489 Compliant Cabinet, 400kW Version USA / Canada
- IB-1-1000-100-1000 - IB-CAB-USA-500 - UL-489 Compliant Cabinet, 500kW Version USA / Canada
- IB-1-1000-100-1000 - IB-CAB-USA-650 - UL-489 Compliant Cabinet, 650kW Version USA / Canada
- IB-1-1000-100-1000 - IB-AC-IN-480 - 480VAC ±10%, 3-Phase Input; 480VAC ± 10% standard mains voltage of 3/PE, for Single-Channel Units
- IB-1-1000-100-1000 - IB-IF-ETHERCAT - EtherCAT Interface (2 each RJ45 Connectors); 100 Mbit/s Transmission Rate
- IB-1-1000-100-1000 - IB-IF-PROFIBUS - Profibus Interface (9-pin DSUB Connector); 12 Mbit/s Transmission Rate
- IB-1-1000-100-1000 - IB-IF-PROFINET - Profinet Interface (2 each RJ45 Connectors); 12 Mbit/s Transmission Rate
- IB-1-1000-100-1000 - IB-IF-HSCAN - High-Speed CAN Bus Interface (1 kHz Rate)
- IB-1-1000-100-1000 - IB-IF-SCPI - SCPI Interface, Single Channel Units Only
- IB-1-1000-100-1000 - IB-CAN-FD - Interface "CAN-FD"; CAN-FD bus interface with a cycle time of 1 ms (1 kHz) for setpoint setting for highly dynamic processes; Price per channel
- IB-1-1000-100-1000 - IB-IF-ANALOG-IN - Analog Input Signal (Voltage = 0-10V Full Scale; Current = ±10V Full Scale)
- IB-1-1000-100-1000 - IB-IF-ANALOG-OUT - Analog Output Signal (Voltage = 0-10V Full Scale; Current = ±10V Full Scale)
- IB-1-1000-100-1000 - IB-IF-HS-ANALOG - High-Speed Analog Control (± 10V = ± Full Scale) for Single Channel Units Only
- IB-1-1000-100-1000 - IB-RC-100MB-VPN - Remote Control VPN for AMETEK Maintenance
- IB-1-1000-100-1000 - IB-RC-100-RENT - Rental fee for remote service module (Tosi-Box); Provision of the remote service module to install a software update on the B&R controller
- IB-1-1000-100-1000 - IB-REMOTEUPDATE - Software Adjustment via Remote Control
- IB-1-1000-100-1000 - IB-TEAM-VIEW - Software adjustment via Teamviewer; communication PC with Internet access required on site
- IB-1-1000-100-1000 - IB-IF-LABVIEW - LabVIEW (NI) Interface with USB to CAN Converter
- IB-1-1000-100-1000 - IB-IF-MATLAB - MATLAB/Simulink Interface, includes PC and B&R Automation Studio Software
- IB-1-1000-100-1000 - IB-IMD - Insulation Monitoring Device – Single Channel Unit Only; Monitors the DUT and Shuts Down the Output when Leakage Resistance falls below 100k ohms. Bender ISOMETER® P/N: iso685
- IB-1-1000-100-1000 - IB-1-ISO-5M - Increase insulation resistance of 1-Channel to > 5 MΩ
- IB-1-1000-100-1000 - IB-BAT-S-1000 - Battery Simulator for 1000V Systems; one each required per channel; output filter optimized for battery simulation by additional electrolytic capacitors
- IB-1-1000-100-1000 - IB-BAT-TS-1000 - Battery Tester/Simulator for 1000V Systems; one each required per channel; output filter optimized by switching in capacitors for the tester or simulator modes
- IB-1-1000-100-1000 - IB-DC-1000 - Output Contactors with Increased Short-time Withstand Current; one each required per channel; Vnom 1500V, thermal continuous current 1000A, short-time withstand current ICW 8kA
- IB-1-1000-100-1000 - IB-DUAL-CR-100-10 - Current Range Switching; Single-Channel only; Range 1: 100% of nominal current, Range 2: 10% of nominal current for measuring low currents only
- IB-1-1000-100-1000 - IB-MEAS-05-CERT - 0.05% Measurement Accuracy, Test Certificate Included; required for each channel
- IB-1-1000-100-1000 - IB-FC-DEXT-1000 - Protection Diode in a Separate Cabinet; Maximum Rating 1000V / 1000A, for Fuel Cell Testing
- IB-1-1000-100-1000 - IB-PCD-1 - Parallel Control Device; upgrade to allow parallel operation of two single-channel units with same voltage/current rating; one required for each single-channel unit
- IB-1-1000-100-1000 - IB-PL-D-PAR - Safety Master Control for Parallel Operation for Performance Level 'd', mounted in an external cabinet
- IB-1-1000-100-1000 - IB-ESTOP-PL-D - Change of safe shutdown time (Emergency Stop); standard setting 5 sec, range 0.5 to 100 sec; includes verification of safety controller software to confirm Performance Level d per DIN EN 13849
- IB-1-1000-100-1000 - IB-ESTOP-2CON - Emergency Stop (E-STOP) Switch (yellow/red) with Protective Collar installed in control cabinet door; includes two potential-free normally open contact connections
- IB-1-1000-100-1000 - IB-DOOR-LOCK - Keyed Door Locks per Cabinet
- IB-1-1000-100-1000 - IB-CAB-LAMP - Cabinet Lamp; cabinet lighting with motion sensor mounted on the cabinet ceiling in the front area; one per cabinet
- IB-1-1000-100-1000 - IB-CAB-BASE-200 - Cabinet Base Frame; raises the cabinet base 200mm (7.87 inch) to accommodate large cross-section cable entry; one per cabinet
- IB-1-1000-100-1000 - IB-CAB-WHEELS - Cabinet Wheels; four wheeled castors per cabinet, two with stop latches; adds 182 mm (7.17 inch) to cabinet height
- IB-1-1000-100-1000 - IB-LIFT-LUGS - Add 4 Lifting Lugs per Cabinet per DIN 580/582; not available for cabinets > 1000 kg
- IB-1-1000-100-1000 - IB-CBOX-800-19800 - External Capacitor Box, 800V, 19,800 uF, plastic enclosure, includes discharge resistors and 5m cables with M10 ring lugs
- IB-1-1000-100-1000 - IB-CBOX-1000-8100 - External Capacitor Box, 1000V, 8100 uF, plastic enclosure, includes discharge resistors and 5m cables with M10 ring lugs
- IB-1-1000-100-1000 - IB-CBOX-P-1000-20000 - External Capacitor Box, 1000V, 20,000 µF, plastic enclosure, includes discharge resistors and 5m cables with M10 ring lugs
- IB-1-1000-100-1000 - IB-CBOX-800-20360 - External Capacitor Box, 800V, 20,360 µF, metal enclosure, includes discharge resistors and 5m cables with M10 ring lugs
- IB-1-1000-100-1000 - IB-CBOX-1000-9660 - External Capacitor Box, 1000V, 9,660 uF, metal enclosure, includes discharge resistors and 5m cables with M10 ring lugs
- IB-1-1000-100-1000 - IB-CBOX-1100-2500 - External Capacitor Box, 1100V, 2500 uF, metal enclosure, includes discharge resistors and 5m cables with M10 ring lugs
- IB-1-1000-100-1000 - IB-CBOX-M-1100-5800 - External Capacitor Box, 1100V, 5800 uF, metal enclosure, includes discharge resistors and 5m cables with M10 ring lugs
- IB-1-1000-100-1000 - IB-PDSB-1-1-1KA-2 - PDSB 1000V / 1000A (1 Input / 1 Output; space for 2 DCU); additional cabinet for i-BEAM for installation of 2 DCUs
- IB-1-1000-100-1000 - IB-PDSB-2-1-2KA-2 - PDSB 1000V / 2000A (2 Input / 1 Output; space for 2 DCU); additional control cabinet for paralleling two i-BEAMs and for installation of 2 DCUs
- IB-1-1000-100-1000 - IB-SAFE-MST-PDSB - Safety Master Control for Parallel Operation (PDSB); required to achieve Performance Level 'd' in parallel operation of two i-BEAMs
- IB-1-1000-100-1000 - IB-PDSB-E-1-2-600-2 - PDSB with contactor 1000V / 600A (1 Input / 2 Output; space for 2 DCU); power distribution from one i-BEAM to two test stands/DUT
- IB-1-1000-100-1000 - IB-PDSB-E-1-2-1K - PDSB with contactor 1000V / 1000A (1 Input / 2 Output); power distribution from one i-BEAM to two test stands/DUT; installation of max. 4 DCU
- IB-1-1000-100-1000 - IB-PDSB-S-1-2-PL-6 - PDSB "safety control" (1 Input / 2 Output); installation of safety controller to achieve performance level "d" per DIN EN 13849
| Model | IB-1-1000-100-1000 |
|---|
SORENSEN IB-1-1000-100-1000 High Performance Regenerative DC Power System
The Sorensen i-BEAM IB-1-1000-100-1000 High Performance Regenerative DC Power System features full DC source and sink capabilities with the power level of 100 kW. It's designed for testing today's complex, high power electronics for the automotive, energy storage, industrial, and aerospace markets in a variety of applications. The IB-1-1000-100-1000 features a color TFT touchscreen with a menu-driven interface for seamless control of system settings. It allows users to set and measure voltage, current, power, and internal resistance values directly through the touchscreen. Programmable voltage and cur ramps, along with the ability to store them for repeated use, enhance flexibility. The system enables setting under voltage limits to prevent deep discharge, safeguarding battery packs. Additionally, event logs provide a comprehensive history of system actions, warnings, and faults.
The Sorensen i-BEAM IB-1-1000-100-1000 High Performance Regenerative DC Power System platform covers test needs through the product life cycle from battery simulation, battery testing (charge/discharge), DC motor testing, electric powertrain testing, fuel cell load testing, solar panel testing, testing high power fuses, contactors, circuit breakers. The IB-1-1000-100-1000 Single-Channel configuration power can flow in either direction, it also features a PDU which provides a remote connection between the i-BEAM and a Device Under Test (DUT) in a test cell. The PDU is configured in a free-standing cabinet and includes shutdown and reset controls, voltmeter, status light tower and a door contact that shuts the system down if the cabinet door is opened.
Specifications for the SORENSEN IB-1-1000-100-1000 High Performance Regenerative DC Power System Include:
| Voltage Range | 5-1000 V |
| Cur Range | ± 1000 A |
| Total Power | 100 kW |




