Tektronix DPO5034

| Attribut | Valeur |
|---|---|
| Nombre de voies | 4 |
| Bande passante | 350 MHz |
| Taux d'échantillonnage | 5 GS/s |
| Longueur d'enregistrement | 25 millions de points |
| Résolution verticale | 8 bits |
| Sensibilité verticale | 1 mV/div à 10 V/div |
| Base de temps | 400 ps/div à 1000 s/div |
| Taux de capture des formes d'onde | jusqu'à 250 000 formes d'onde par seconde |
| Écran | Écran couleur LCD 10,4 pouces (264 mm) |
| Interfaces de connectivité | USB, LAN (LXI), DisplayPort |
Tektronix DPO5034 Options:
- DPO5034 - 2RL - 25 M/Ch record length
- DPO5034 - 5RL - 50 M/Ch record length
- DPO5034 - 10RL - 125 M/Ch record length
- DPO5034 - SSD - Solid state hard disk drive, ≥300 GB
- DPO5034 - DDRA - DDR Memory bus analysis (Requires Opt. DJA) (Available on 1 GHz and 2 GHz models only.)
- DPO5034 - DJA - Jitter and Eye Analysis Tools – Advanced (DPOJET)
- DPO5034 - ET3 - Ethernet compliance test (Requires TF-GBE-BTP or TF-GBE-ATP Ethernet Test Fixture)
- DPO5034 - HSIC - USB HSIC protocol decode and electrical validation (Available on 2 GHz models only.)
- DPO5034 - LT - Waveform limit testing
- DPO5034 - MOST - MOST Essentials – Electrical compliance and debug test solution for MOST50 and MOST150 (Requires Opt. DJA)
- DPO5034 - MTM - Mask testing
- DPO5034 - PWR - Power measurement and analysis
- DPO5034 - SR-AERO - Aerospace serial triggering and analysis (MIL-STD-1553)
- DPO5034 - SR-AUTO - Automotive serial triggering and analysis (CAN/LIN/FlexRay)
- DPO5034 - SR-COMP - Computer serial triggering and analysis (RS-232/422/485/UART)
- DPO5034 - SR-DPHY - MIPI® D-PHY serial analysis
- DPO5034 - SR-EMBD - Embedded serial triggering and analysis (I2C, SPI)
- DPO5034 - SR-ENET - Ethernet serial triggering and analysis (10BASE-T, 100BASE-TX)
- DPO5034 - SR-PCIE - PCI Express serial analysis (Available on ≥1 GHz models only.)
- DPO5034 - SR-USB - USB 2.0 serial triggering and analysis (LS, FS, HS)
- DPO5034 - SR-810B - 8b/10b serial analysis
- DPO5034 - SVA - SignalVu® AM/FM/PM/Direct audio measurements (Requires Opt. SVE)
- DPO5034 - SVE - SignalVu® Essentials – Vector signal analysis software
- DPO5034 - SVM - SignalVu® General purpose modulation analysis (Requires Opt. SVE)
- DPO5034 - SVP - SignalVu® Pulse – Advanced signal analysis (Requires Opt. SVE)
- DPO5034 - SVT - SignalVu® Settling time measurements – frequency and phase (Requires Opt. SVE)
- DPO5034 - USB - USB 2.0 Compliance testing (Requires TDSUSBF (USB Test Fixture). 2 GHz bandwidth required for high-speed USB)
- DPO5034 - USBPWR - Automated compliance test solution for USB power adapters
- DPO5034 - VET - Visual Trigger and Search
- DPO5034 - VNM - CAN/LIN Protocol analysis software
- DPO5034 - PS1 - Power Solution Bundle: DPOPWR, P5205A, TCP0030A, TPA-BNC, 067-1686-xx (Deskew fixture), 119-7465-xx (external probe power supply)
- DPO5034 - PS2 - Power Solution Bundle: DPOPWR, THDP0200, TCP0030A, 067-1686-xx (Deskew fixture)
- DPO5034 - PS3 - Power Solution Bundle: DPOPWR, TMDP0200, TCP0020, 067-1686-xx (Deskew fixture)
- DPO5034 - A0 - North America power plug (115 V, 60 Hz)
- DPO5034 - A1 - Universal Euro power plug (220 V, 50 Hz)
- DPO5034 - A2 - United Kingdom power plug (240 V, 50 Hz)
- DPO5034 - A3 - Australia power plug (240 V, 50 Hz)
- DPO5034 - A5 - Switzerland power plug (220 V, 50 Hz)
- DPO5034 - A6 - Japan power plug (100 V, 110/120 V, 60 Hz)
- DPO5034 - A10 - China power plug (50 Hz)
- DPO5034 - A11 - India power plug (50 Hz)
- DPO5034 - A12 - Brazil power plug (60 Hz)
- DPO5034 - A99 - No power cord
- DPO5034 - L0 - English manual
- DPO5034 - L1 - French manual
- DPO5034 - L3 - German manual
- DPO5034 - L5 - Japanese manual
- DPO5034 - L7 - Simplified Chinese manual
- DPO5034 - L8 - Traditional Chinese manual
- DPO5034 - L9 - Korean manual
- DPO5034 - L10 - Russian manual
- DPO5034 - L99 - No manual
- DPO5034 - C3 - Calibration Service 3 Years
- DPO5034 - C5 - Calibration Service 5 Years
- DPO5034 - D1 - Calibration Data Report
- DPO5034 - D3 - Calibration Data Report 3 Years (with Opt. C3)
- DPO5034 - D5 - Calibration Data Report 5 Years (with Opt. C5)
- DPO5034 - G3 - Complete Care 3 Years (includes loaner, scheduled calibration, and more)
- DPO5034 - G5 - Complete Care 5 Years (includes loaner, scheduled calibration, and more)
- DPO5034 - R3 - Repair Service 3 Years (including warranty)
- DPO5034 - R5 - Repair Service 5 Years (including warranty)
| Model | DPO5034 |
|---|
Le Tektronix DPO5034 dispose de 4 canaux analogiques avec une bande passante de 350 MHz et un taux d'échantillonnage allant jusqu'à 5 GS/s (10 GS/s sur un ou deux canaux), ainsi qu'une mémoire standard de 12,5 M points. FastAcq® permet plus de 250 000 formes d'onde/s, et FastFrame™ capture segmentée prend en charge jusqu'à 290 000 segments avec plus de 310 000 formes d'onde/s—idéal pour la capture de signaux haute vitesse.
Doté de l'interface Wave Inspector®, de 53 mesures automatiques, FFT, histogrammes, diagrammes d'œil, analyse de gigue, déclenchement/décodage de protocoles en option et un écran tactile XGA de 10,4″, il excelle dans l’analyse approfondie de formes d’onde.
Testwall peut fournir le Tektronix DPO5034 d'occasion, entièrement testé. Avec un support expert et une livraison mondiale, Testwall garantit des instruments haute performance avec une fiabilité et une qualité de service inégalées. Contactez-nous si vous avez besoin d'une calibration ou réparation du Tektronix DPO5034.