emtest UCS200N

Produttoreemtest
ModelloUCS200N
ProdottoAutomotive Transient Tester

 

emtest NX5

emtest NX5

emtest UCS500N5

emtest UCS500N5

Ottieni un preventivo
SKU
124891
EMTEST UCS200N / EM Test UCS 200NThe EM Test UCS 200N Ultra-Compact Simulator for Automotive Transients unifies the capabilites of an EFT/Burst simualtor, a Micropulse simulator and the required coupling network into one box. The UCS 200N Transient Tester is equiped to meet all international and car manufacturer specifications from around the globe. The built-in coupling network ranges from 50A, up to 200A depending on the model / option specified. The built-in coupling network can be used and controlled by any unit of the LD 200N, VDS 200N and PFS 200N. For tests beyond standard's requirements the waveform parameters of the Micropulse generator can be varied in a wide range by means of the FreeStyle mode.The EM Test UCS200N has the following specifications:UCS 200N MODELS
  • UCS 200N50 Built-in coupling/decoupling network, 80V/50A, 100A@500ms
  • UCS 200N100 Built-in coupling/decoupling network, 80V/100A, 150A@500ms
  • UCS 200N150 Built-in coupling/decoupling network, 80V/150A
  • UCS 200N200 Built-in coupling/decoupling network, 80V/200A
  • INPUT:
  • DUT supply +/-: DC voltage from VDS 200N or any other DC supply
  • Pulse 5, 7: From one LD 200N
  • OUTPUT:
  • DUT supply +/-: Central DUT output
  • Coaxial output port: To connect the capacitive coupling clamp as per ISO 7637-3:2007
  • ELECTRICAL FAST TRANSIENTS EFT/BURST MODULE FOR TEST PULSES 3A/3B As per ISO 7637-2
  • Test voltage: 25V - 1,000V ± 10%
  • Rise time: 5ns ± 1.5ns
  • Pulse duration: 150ns ± 45ns
  • Verification: As per Annex C of ISO 7637-2:2011 into 50ohm and 1,000ohm load
  • Source impedance: Zq = 50ohm
  • Polarity: Positive/negative (Pulse 3b/3a)
  • TRIGGER CIRCUIT
  • Trigger of bursts Automatic: manual, external
  • Burst duration: T4 = 0.1ms - 999.9ms
  • Repetition rate: T5 = 10ms - 9,999ms
  • Spike frequency: f = 0.1kHz - 200kHz
  • Test duration: T = 0:01min - 999:59min, T > 999:59min --> endless
  • OUTPUTS
  • Direct: Via 50ohm-coaxial connector (for tests using e.g. a capacitive
  • coupling clamp)
  • Coupling mode: To the + battery line (supply lines)
  • CRO trigger: 5V trigger signal for Oscilloscope
  • TEST ROUTINES
  • Quick Start: On-line adjustable parameters, easy-to-use
  • Standard Test Routines: As per ISO 7637-2:2011, Levels 1 - 4
  • User Test Routines: Random burst release. Change voltage after T. Change frequency after T
  • MICROPULSES MICROPULSE MODULE FOR TEST PULSES 1, 2A AND 6: As per ISO 7637-2:2011
  • Test voltage:  U = 20V - 600V ± 10% (peak voltage and polarity as per selected standard)
  • Repetition rate: 0.2s - 99.0s
  • ISO PULSE 1 (12V)
  • Rise time: 1us +0%/-50% (10% - 90%)
  • Pulse duration: 2ms ± 10% (10% - 10%)
  • Int. resistor: 10ohm ± 10%
  • ISO PULSE 1 (24V)
  • Rise time: 3us +0%/-50% (10% - 90%)
  • Pulse duration: 1ms ± 10 (10% - 10%)
  • Int. resistor: 50ohm ± 10% 
  • ISO PULSE 2 (12V/24V)
  • Rise time: 1us +0%/-50% (10% - 90%)
  • Pulse duration: 50us ± 10% (10% - 10%)
  • Int. resistor: 2ohm ± 10%
  • ISO PULSE 6 (12V) AS PER ISO 7637-1:1990
  • Rise time: 60us +0%/-50% (10% - 90%)
  • Pulse duration: 300us ± 10% (10% - 10%)
  • Int. resistor: 30ohm ± 10% 
  • AS PER ISO 7637-2 THE FOLLOWING STANDARDS CAN BE COVERED
  • SAE J1113
  • GM 3097
  • BMW
  • Volkswagen
  • PSA
  • Chrysler PF 9326
  • DC 10614
  • Renault
  • FIAT
  • Mitsubishi
  • Honda
  • Ford ES-XW7T
  • TRIGGER
  • Automatic: Automatic release of the pulses
  • Manual: Manual release of a single pulse
  • External: External release of a single pulse
  • Battery switch: Off time, selectable; 0 - 10,000ms
  • OUTPUT
  • DUT supply +/-: Central DUT output
  • Coupling: To the battery +line
  • Decoupling: Via diode and battery supply switch
  • TEST ROUTINES
  • Quick Start: Immediate start; easy to use and fast
  • User Test Routines: 1. Custom made test routines and 2. Change voltage after n pulses
  • Standard Test Routines: As per ISO 7637, SAE J1113, JASO and manufacturer specifications
  • Service: Service, setup, self test
  •     

    Resi

    Se non sei completamente soddisfatto del tuo acquisto, restituisci semplicemente l’articolo nelle condizioni originali entro 30 giorni dalla ricezione. Gli articoli restituiti devono essere inutilizzati e riconsegnati nell’imballaggio originale con tutta la documentazione allegata. Emetteremo un rimborso completo al ricevimento, escluse le spese di spedizione iniziali. In alternativa, se preferisci, possiamo sostituire l’articolo.

    IVA

    I prezzi sono al netto dell’IVA. Transazioni intracomunitarie: Secondo la Direttiva IVA dell’UE, le vendite B2B di beni all’interno dell’UE sono esenti da IVA. Dove applicata, l’aliquota IVA è del 23%. L’IVA non viene addebitata al di fuori dell’UE.

    Clicky