RENT KEYSIGHT 8990B (AGILENT) Peak Power Analyzer (call for availability)
The Keysight 8990B (Agilent) Peak Power Analyzer offers faster measurement speed and greater measurement accuracy in key applications such as radar pulse analysis and wireless pulse measurement. Designed with both ease of use and high performance in mind the Agilent 8990B Peak Power Analyzer saves you time and effort allowing you to focus on the important details. When used with a compatible peak power sensor, this analyzer is able to measure the dynamic or time-dependent aspects of RF and microwave power.
Features and Specifications of the Keysight 8990B (Agilent) Peak Power Analyzer include:
Provides internal and external trigger functions
20X zooming capability with dual Screen Zoom Window
Internal Zeroing and Calibration
Touchscreen Capability
Frequency Range: 50 MHz to 40 GHz (sensor dependent)
Dynamic range: -35 to +20dBm (CW) and -25 to +20dBm (Pulse)
Short System Rise/ Fall time of 5nsec (-20 to +20dBm)
100 MSa/ sec continuous sampling with >1500 readings/ sec
Channels are compatible with U2000 Series power sensors connected using the USB hosts
Provide 15 Pulse Characterization Measurement
Automated pulse delay measurement between channels
4 channels (RF and Video):
RF Channels are 1 and 4
Frequency Range: 50 MHz to 40 GHz
Dynamic Range: €“35 dBm to +20 dBm
Measurement Unit: linear (Watt) or Log (dBm) selectable
Video Bandwidth: 150 MHz
Max Pulse Width: 150 MHz
Max Pulse Repetition Rate: 10 MHz
Input Coupling: 50 O
Vertical Scale:
0.01 dB/div to 100 dB/div in 1-2-5 sequence or any arbitrary scaling, user defined
1 uW/div to 1 kW/div in 1-2-5 sequence or any arbitrary scaling, user defined
Offset: ± 99 dBm with 0.01 dB resolution
Video Channels are 2 and 3
Video Inputs allow the simultaneous analysis of time-domain control signals
Video Bandwidth: 1GHz
Input Impedance:
50 O ± 2.5%,1 MO ± 1% (11 pF typical)
Input Coupling:
1 MO: AC (3.5 Hz), DC
50 O: DC
Vertical Scale:
1 MO: 1 mV/div to 5 V/div in 1-2-5 sequence or any arbitrary scaling, user defined
50 O: 1 mV/div to 1 V/div in 1-2-5 sequence or any arbitrary scaling, user defined
DC Gain Accuracy: ± 5% of full scale at full resolution on channel scale ± 5 °C from cal temp
Offset Accuracy: ± (1.25% of channel offset +1% of full scale + 1 mV)
Se non sei completamente soddisfatto del tuo acquisto, restituisci semplicemente l’articolo nelle condizioni originali entro 30 giorni dalla ricezione.
Gli articoli restituiti devono essere inutilizzati e riconsegnati nell’imballaggio originale con tutta la documentazione allegata. Emetteremo un rimborso completo al ricevimento, escluse le spese di spedizione iniziali. In alternativa, se preferisci, possiamo sostituire l’articolo.
IVA
I prezzi sono al netto dell’IVA.
Transazioni intracomunitarie: Secondo la Direttiva IVA dell’UE, le vendite B2B di beni all’interno dell’UE sono esenti da IVA.
Dove applicata, l’aliquota IVA è del 23%.
L’IVA non viene addebitata al di fuori dell’UE.