Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) N1923A

Wideband Peak Power Sensor, 50 MHz to 18 GHz
50 MHz - 18 GHz Intervallo di frequenza
-35 dBm a +20 dBm Intervallo di potenza
Type-N (50 Ω) Connettore RF
±0,9% (a 50 MHz, 0 dBm, 25°C) Incertezza di calibrazione
USB 2.0 Interfaccia di comunicazione
Richiedi scheda tecnica
Attributo Valore
Intervallo di frequenza 50 MHz - 18 GHz
Intervallo di potenza -35 dBm a +20 dBm
Connettore RF Type-N (50 Ω)
Incertezza di calibrazione ±0,9% (a 50 MHz, 0 dBm, 25°C)
Interfaccia di comunicazione USB 2.0
Tempo di risposta Inferiore a 200 ms (modalità normale)
Temperatura di esercizio 0°C a +55°C
Alimentazione Alimentato tramite USB (bus USB)
Dimensioni (L x A x P) Sensore compatto per utilizzo portatile
Compatibilità strumenti Compatibile con Keysight N1918A Power Analysis Manager e analizzatori di spettro Keysight
Keysight (Agilent) N1923A Options:
  • N1923A - 105 - Fixed cable option length, 1.5 m (5 ft)
  • N1923A - 106 - Fixed cable option length, 3 m (10 ft)
  • N1923A - 1A7 - Certificate of compliance calibration - ISO 17025 with test data; printed
  • N1923A - A6J - Certificate of compliance calibration - ANSI Z540 with test data; printed
  • N1923A - ABJ - Japan, Japanese user guide, printed
  • N1923A - 0B1 - English language user guide, printed
  • N1923A - 0BN - English language service guide, printed
Modulo di calibrazione Keysight (Agilent) N1923A

Modulo di riparazione Keysight (Agilent) N1923A
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
ModelN1923A

RENT  KEYSIGHT N1923A (Agilent) Power Sensor (call for availability)

The Keysight N1923A Wideband Power Sensor   provides internal zero and calibration by uniquely integrating a DC reference source and switching circuits into the power sensor. This feature eliminates the multiple connections associated with using an external calibration source, thus minimizing connector wear, test-time and measurement uncertainty.

Features and Specifications of the Keysight N1923A (Agilent) Power Sensor include:

  • Zero and calibrate while connected to the DUT
  • Wide Dynamic Range for peak power measurements:   -35 dBm to +20 dBm
  • Calibration factors, linearity, temperature and bandwidth correction data stored in EEPROM
  • Precision N-type connector as standard
  • Sensor Cable:
    • Fixed to sensor
    • Available cable lengths:  
      • 1.5m (5ft)
      • 3m (10ft)

 