Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) E4443A

Spectrum Analyzer, 3 Hz - 6.7 GHz (PSA Series)
3 Hz to 6.7 GHz Frequency Range
-152 dBm (nominal, 1 Hz RBW, preamp on) Displayed Average Noise Level (DANL)
-114 dBc/Hz at 10 kHz offset (carrier at 1 GHz) Phase Noise
±0.19 dB (total amplitude accuracy) Amplitude Accuracy
1 Hz to 3 MHz (in 10% steps), plus 4, 5, 6, and 8 MHz Resolution Bandwidth (RBW)
Request datasheet
Attribute Value
Frequency Range 3 Hz to 6.7 GHz
Displayed Average Noise Level (DANL) -152 dBm (nominal, 1 Hz RBW, preamp on)
Phase Noise -114 dBc/Hz at 10 kHz offset (carrier at 1 GHz)
Amplitude Accuracy ±0.19 dB (total amplitude accuracy)
Resolution Bandwidth (RBW) 1 Hz to 3 MHz (in 10% steps), plus 4, 5, 6, and 8 MHz
Dynamic Range Up to 78 dB (third-order intermodulation dynamic range)
Input Impedance 50 Ohm
Maximum Input Power +30 dBm (1 W) continuous, ±50 VDC
Sweep Time 1 ms to 4000 s (span > 0 Hz)
Connectivity / Interface GPIB, LAN (10/100Base-T), RS-232, USB
Keysight (Agilent) E4443A Options:
  • E4443A - 1DS - RF internal preamplifier (100 kHz to 3 GHz)
  • E4443A - 110 - RF/µW internal preamplifier (10 MHz to upper frequency limit of the PSA)
  • E4443A - B7J - Digital demodulation hardware
  • E4443A - 122 - 80 MHz bandwidth digitizer
  • E4443A - 140 - 40 MHz bandwidth digitizer
  • E4443A - 123 - Switchable MW preselector bypass
  • E4443A - 124 - Y-axis video output
  • E4443A - AYZ - External mixing
  • E4443A - 107 - Audio input 100 kΩ
  • E4443A - 111 - USB device side I/O interface
  • E4443A - 115 - 512 MB user memory
  • E4443A - 117 - Secure memory erase
  • E4443A - H70 - 70 MHz IF output
  • E4443A - HYX - 21.4 MHz IF output
  • E4443A - 226 - Phase noise measurement personality
  • E4443A - 219 - Noise figure measurement personality
  • E4443A - 241 - Flexible digital modulation analysis personality
  • E4443A - BAF - W-CDMA measurement personality
  • E4443A - 210 - HSDPA/HSUPA (for W-CDMA) measurement personality
  • E4443A - 202 - GSM w/ EDGE measurement personality
  • E4443A - B78 - cdma2000 measurement personality
  • E4443A - 214 - 1xEV-DV measurement personality
  • E4443A - 204 - 1xEV-DO measurement personality
  • E4443A - BAC - cdmaOne measurement personality
  • E4443A - BAE - NADC, PCD measurement personality
  • E4443A - 217 - WLAN measurement personality
  • E4443A - 211 - TD-SCDMA power measurement personality
  • E4443A - 212 - TD-SCDMA modulation personality
  • E4443A - 213 - HSPA for TD-SCDMA personality
  • E4443A - 215 - External source control personality
  • E4443A - 266 - Programming code compatibility suite
  • E4443A - 233 - Built-in measuring receiver personality
  • E4443A - 23A - AM/FM/PM triggering
  • E4443A - 23B - CCITT filter
  • E4443A - 239 - N9039A RF preselector control
  • E4443A - 230 - BenchLink Web Remote Control Software
  • E4443A - 235 - Wide BW digitizer external calibration wizard
  • E4443A - 0BW - Service manual
  • E4443A - UK6 - Commercial calibration certificate with test data
  • E4443A - A6J - Factory ANSI Z540 standard-compliant calibration
  • E4443A - 1A7 - Factory ISO 17025 standard-compliant calibration
  • E4443A - 1CM - Rack mount kit
  • E4443A - 1CN - Front handle kit
  • E4443A - 1CP - Rack mount with handles
  • E4443A - 1CR - Rack slide kit
  • E4443A - 015 - 6 GHz return loss measurement accessory kit
  • E4443A - 045 - Millimeter wave accessory kit
  • E4443A - 0B1 - Extra manual set including CD ROM
Calibration Form Keysight (Agilent) E4443A

Repair Form Keysight (Agilent) E4443A
Maximum file size: 40MB

No Related Posts

More Information
ModelE4443A

The Keysight E4443A (Agilent) PSA offers high-performance spectrum analysis, up to 6.7 GHz, with powerful one-button measurements, a versatile feature set, and a leading-edge combination of flexibility, speed, accuracy, analysis bandwidth, and dynamic range.

Other features and specifications include:

  • Frequency range: 3 Hz - 6.7 GHz
  • All-digital IF with auto-ranging capability
  • Standard 10 MHz analysis bandwidth
  • Optional 40 or 80 MHz analysis bandwidth to capture and measure complex signals
  • -78 dB (nominal) third order intermodulation for 40 or 80 MHz analysis bandwidth
  • Phase noise optimization  
  • Full detector suite  
  • 160 resolution bandwidth settings (10% steps)  
  • Typical Performance @ 1 GHz: Dynamic range (-155 dBm DANL, +19 dBm TOI, -118 dBc/Hz phase noise at 10 kHz offset; Accuracy ( ±0.19 dB absolute amplitude accuracy, ±0.11 dB frequency response)
  • 2 dB step attenuator  
  • FFT and swept measurement modes  
  • Gated sweep  
  • Power Suite one-button power measurements  
  • EMI measurements with CISPR compliant bandwidths and detectors

 

Clicky Copyright © 2025-present Magento, Inc. All rights reserved.