Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) N4691D

Electronic Calibration Module (ECal), 26.5 GHz, 3.5 mm, 2-port
300 kHz to 26.5 GHz Frequency Range
2.4 mm (male/female) Connector Type
2-Port Number of Ports
Electronic Calibration (ECal) Module Calibration Standard Type
Less than 3 dB typical Insertion Loss
Request datasheet
Attribute Value
Frequency Range 300 kHz to 26.5 GHz
Connector Type 2.4 mm (male/female)
Number of Ports 2-Port
Calibration Standard Type Electronic Calibration (ECal) Module
Insertion Loss Less than 3 dB typical
Impedance 50 Ohm
Compatible Instruments Keysight PNA, PNA-L, PNA-X, ENA Series Vector Network Analyzers
Interface USB
Operating Temperature 0°C to 55°C (32°F to 131°F)
Return Loss Greater than 22 dB typical
Keysight (Agilent) N4691D Options:
  • N4691D - 0DC - Low frequency starts from DC
  • N4691D - 003 - Low frequency starts from 300 kHz
  • N4691D - M0F - 1 female and 1 male connector (3.5 mm)
  • N4691D - F0F - Both connectors are female (3.5 mm)
  • N4691D - M0M - Both connectors are male (3.5 mm)
  • N4691D - 00A - Add male-to-male and female-to-female adapters
  • N4691D - 1A7 - Calibration + Uncertainties + Guardbanding (Not Accredited)
  • N4691D - A6J - ANSI Z540-1-1994 calibration
  • N4691D - UK6 - Commercial calibration certificate with test data
Calibration Form Keysight (Agilent) N4691D

Repair Form Keysight (Agilent) N4691D
Maximum file size: 40MB

No Related Posts

More Information
ModelN4691D

 Keysight (Agilent) N4691D Electronic Calibration Module

 

The Keysight N4691D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4691D is a precision 2-port ECal module that supports 3.5 mm connectors up to 26.5 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4691D is included for securing your ECal module and accessories.

The N4691D Option 0DC extends the calibration frequency range down to DC, which is beneficial for broadband device modeling or time domain and signal integrity analysis using enhanced time domain-analysis on the Keysight network analyzers.

This ECal module is an ideal solution for calibrating vector network analyzers. Performing a full two-port calibration takes less than half the time and number of connections versus traditional mechanical cal kits. The operator simply connects the ECal module to the vector network analyzer via USB and the firmware controls the rest, thus reducing the chance for operator error. Wear and tear on connectors is reduced as well, lowering repair costs on both the test port connectors and calibration standards.

 

Specifications for the  Keysight (Agilent) N4691D Electronic Calibration Module Include:

Frequency Range 300 kHz to 26.5 GHz (DC to 26.5 GHz w/Opt 0DC)
Ports 2
Connector Type 3.5mm

 