Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) N9010A-513 10 Hz to 13 GHz Spectrum Analyser (Signal Analyser)

10 Hz to 13 GHz Spectrum Analyser (Signal Analyser)
10 Hz to 13 GHz Frequency Range
-163 dBm/Hz (typical, with preamplifier enabled) Displayed Average Noise Level (DANL)
-98 dBc/Hz at 10 kHz offset (typical, at 1 GHz carrier) Phase Noise
1 Hz to 8 MHz (–3 dB bandwidth) Resolution Bandwidth (RBW)
+15 dBm (typical, at 50 MHz, mixer level –10 dBm) Third-Order Intercept (TOI)
Request datasheet
Attribute Value
Frequency Range 10 Hz to 13 GHz
Displayed Average Noise Level (DANL) -163 dBm/Hz (typical, with preamplifier enabled)
Phase Noise -98 dBc/Hz at 10 kHz offset (typical, at 1 GHz carrier)
Resolution Bandwidth (RBW) 1 Hz to 8 MHz (–3 dB bandwidth)
Third-Order Intercept (TOI) +15 dBm (typical, at 50 MHz, mixer level –10 dBm)
Maximum Input Power +30 dBm (1 W) at the RF input port
Amplitude Accuracy ±0.19 dB (typical total amplitude uncertainty)
Analysis Bandwidth Up to 25 MHz (real-time analysis bandwidth)
Input Impedance 50 Ohm nominal
Display 10.4-inch color XGA LCD touchscreen display
Keysight (Agilent) N9010A-513 10 Hz to 13 GHz Spectrum Analyser (Signal Analyser) Options:
  • N9010A-513 - 503 - Frequency option: 10 Hz to 3.6 GHz
  • N9010A-513 - 507 - Frequency option: 10 Hz to 7.0 GHz
  • N9010A-513 - 513 - Frequency option: 10 Hz to 13.6 GHz
  • N9010A-513 - 526 - Frequency option: 10 Hz to 26.5 GHz
  • N9010A-513 - 532 - Frequency option: 10 Hz to 32 GHz
  • N9010A-513 - 544 - Frequency option: 10 Hz to 44 GHz
  • N9010A-513 - PFR - Precision frequency reference
  • N9010A-513 - FSA - Fine step attenuator: 0 to 60 dB in 2 dB steps
  • N9010A-513 - EA3 - Electronic attenuator (10 Hz to 3.6 GHz, 0 to 24 dB in 1 dB steps)
  • N9010A-513 - P03 - Preamplifier, 100 kHz to 3.6 GHz
  • N9010A-513 - P07 - Preamplifier, 100 kHz to 7 GHz
  • N9010A-513 - P13 - Preamplifier, 100 kHz to 13.6 GHz
  • N9010A-513 - P26 - Preamplifier, 100 kHz to 26.5 GHz
  • N9010A-513 - P32 - Preamplifier, 100 kHz to 32 GHz
  • N9010A-513 - P44 - Preamplifier, 100 kHz to 44 GHz
  • N9010A-513 - NFE - Noise floor extension
  • N9010A-513 - MPB - Microwave preselector bypass (3.6 to 13.6 GHz for Option 513)
  • N9010A-513 - B25 - 25 MHz analysis bandwidth (standard)
  • N9010A-513 - B40 - 40 MHz analysis bandwidth
  • N9010A-513 - PC4 - High-performance processor for faster measurement speed
  • N9010A-513 - CR3 - Wideband IF output
  • N9010A-513 - CRP - Programmable IF output (10 to 75 MHz user selectable)
  • N9010A-513 - EXM - External mixing (available only with millimeter wave Options 532 or 544)
  • N9010A-513 - EMC - EMI bandwidths (CISPR and MIL STD 461E compliant)
  • N9010A-513 - DP2 - Digital processor upgrade (16-bit ADC, 100 MSa/s sample rate)
  • N9010A-513 - EP3 - Enhanced performance level 3
  • N9010A-513 - EP5 - Enhanced performance level 5
Calibration Form Keysight (Agilent) N9010A-513 10 Hz to 13 GHz Spectrum Analyser (Signal Analyser)

Repair Form Keysight (Agilent) N9010A-513 10 Hz to 13 GHz Spectrum Analyser (Signal Analyser)
Maximum file size: 40MB

No Related Posts

More Information
ModelN9010A-513

The Keysight (Agilent) N9010A-513 Spectrum Analyser delivers up to 300 V/100 A and 15 kW power capacity, ensuring a perfect balance of voltage and current for complex testing scenarios. It supports 0–300 V and 0–100 A ranges, featuring fast slew rates, precise internal metering, and GPIB/LAN programmable interfaces with embedded safety protocols.

Ideal for rigorous testing, the N9010A-513 excels with its high-resolution control and built-in safety, supporting accurate and flexible performance under varied conditions.

Testwall can supply the used Keysight (Agilent) N9010A-513, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Keysight (Agilent) N9010A-513.