Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) N9010A-544 10 Hz to 44 GHz Spectrum Analyser (Signal Analyser)

10 Hz to 44 GHz Spectrum Analyser (Signal Analyser)
10 Hz to 44 GHz Frequency Range
-163 dBm/Hz (with preamplifier enabled, typical) Displayed Average Noise Level (DANL)
-104 dBc/Hz at 10 kHz offset (1 GHz carrier, typical) Phase Noise
1 Hz to 8 MHz (10% steps), plus 1, 3 sequence Resolution Bandwidth (RBW)
±0.19 dB (total amplitude accuracy, typical) Amplitude Accuracy
Request datasheet
Attribute Value
Frequency Range 10 Hz to 44 GHz
Displayed Average Noise Level (DANL) -163 dBm/Hz (with preamplifier enabled, typical)
Phase Noise -104 dBc/Hz at 10 kHz offset (1 GHz carrier, typical)
Resolution Bandwidth (RBW) 1 Hz to 8 MHz (10% steps), plus 1, 3 sequence
Amplitude Accuracy ±0.19 dB (total amplitude accuracy, typical)
Third-Order Intercept (TOI) +15 dBm (at 50 MHz, typical)
Input Attenuator Range 0 to 70 dB (in 2 dB steps)
Maximum Input Power +30 dBm (1 W) continuous, DC coupled
Sweep Time 1 ms to 4000 s (span > 10 Hz), 1 µs to 4000 s (zero span)
Connectivity & Interface LAN (1000Base-T), USB 2.0, GPIB; supports SCPI and IVI-COM drivers
Keysight (Agilent) N9010A-544 10 Hz to 44 GHz Spectrum Analyser (Signal Analyser) Options:
  • N9010A-544 - 503 - Frequency option: 10 Hz to 3.6 GHz
  • N9010A-544 - 507 - Frequency option: 10 Hz to 7 GHz
  • N9010A-544 - 513 - Frequency option: 10 Hz to 13.6 GHz
  • N9010A-544 - 526 - Frequency option: 10 Hz to 26.5 GHz
  • N9010A-544 - 532 - Frequency option: 10 Hz to 32 GHz
  • N9010A-544 - 544 - Frequency option: 10 Hz to 44 GHz
  • N9010A-544 - PFR - Precision frequency reference
  • N9010A-544 - FSA - Fine step attenuator: 0 to 60 dB in 2 dB steps
  • N9010A-544 - EA3 - Electronic attenuator, 10 Hz to 3.6 GHz, 0 to 24 dB in 1 dB steps
  • N9010A-544 - P03 - Preamplifier, 100 kHz to 3.6 GHz
  • N9010A-544 - P07 - Preamplifier, 100 kHz to 7 GHz
  • N9010A-544 - P13 - Preamplifier, 100 kHz to 13.6 GHz
  • N9010A-544 - P26 - Preamplifier, 100 kHz to 26.5 GHz
  • N9010A-544 - P32 - Preamplifier, 100 kHz to 32 GHz
  • N9010A-544 - P44 - Preamplifier, 100 kHz to 44 GHz
  • N9010A-544 - B25 - 25 MHz analysis bandwidth (standard)
  • N9010A-544 - B40 - 40 MHz analysis bandwidth
  • N9010A-544 - NFE - Noise floor extension
  • N9010A-544 - MPB - Microwave preselector bypass, 3.6 to 44 GHz
  • N9010A-544 - EXM - External mixing (available only with millimeter wave Option 532 or 544)
  • N9010A-544 - EMC - EMI bandwidths (CISPR and MIL STD 461E compliant)
  • N9010A-544 - CR3 - Wideband IF output
  • N9010A-544 - CRP - Programmable IF output
  • N9010A-544 - PC4 - Enhanced measurement speed option
  • N9010A-544 - DP2 - Digital processor with 16-bit ADC and 100 MSa/s sample rate
  • N9010A-544 - YAS - Option for use with N9063A analog demodulation application
Calibration Form Keysight (Agilent) N9010A-544 10 Hz to 44 GHz Spectrum Analyser (Signal Analyser)

Repair Form Keysight (Agilent) N9010A-544 10 Hz to 44 GHz Spectrum Analyser (Signal Analyser)
Maximum file size: 40MB

No Related Posts

More Information
ModelN9010A-544

The Keysight (Agilent) N9010A EXA Signal Analyzer offers frequency coverage from 9 kHz to 44 GHz with analysis bandwidth options of 10 MHz and 25 MHz, ensuring high-speed, accurate signal capture and performance.

It supports advanced applications like LTE, W-CDMA, and phase noise analysis, with MATLAB® integration for visualization and measurement automation.

Testwall can supply the used Keysight (Agilent) N9010A EXA Signal Analyzer, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Keysight (Agilent) N9010A EXA Signal Analyzer.