Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) 66321B

0 to 15 V Output Voltage Range
0 to 3 A Output Current Range
45 W Maximum Output Power
100/115/230 VAC, 47-63 Hz Input Voltage
GPIB (IEEE-488) Programming Interface
Request datasheet
Attribute Value
Output Voltage Range 0 to 15 V
Output Current Range 0 to 3 A
Maximum Output Power 45 W
Input Voltage 100/115/230 VAC, 47-63 Hz
Programming Interface GPIB (IEEE-488)
Voltage Programming Accuracy 0.04% + 5 mV
Current Programming Accuracy 0.1% + 3 mA
Output Ripple and Noise (RMS) 2 mV rms / 50 mV peak-to-peak
Operating Temperature Range 0°C to 55°C
Form Factor / Dimensions Half-rack, 2U; 88.1 mm H x 212.6 mm W x 348.3 mm D
Keysight Technologies 66321B Options:
  • 66321B - Opt 100 - 87 to 106 Vac, 47 to 63 Hz
  • 66321B - Opt 120 - 104 to 127 Vac, 47 to 63 Hz
  • 66321B - Opt 220 - 191 to 233 Vac, 47 to 63 Hz
  • 66321B - Opt 230 - 207 to 253 Vac, 47 to 63 Hz
  • 66321B - Opt 004 - Make "Hi Compensation Mode" as default setting
  • 66321B - Opt 053 - Add 14565A Device Characterization Software with Battery Drain Analysis
  • 66321B - Opt 8ZJ - Delete feet
  • 66321B - Opt 8ZL - Include feet
  • 66321B - Opt 1CM - Rack-mount kit (p/n 5062-3975)
  • 66321B - Opt AXS - Rack-mount Kit for side-by-side mounting
  • 66321B - Opt 0B0 - Delete standard documentation package
  • 66321B - Opt 0L1 - Include standard documentation package
  • 66321B - Opt 0L2 - Include extra standard documentation package
  • 66321B - Opt 0B3 - Include service manual
Calibration Form Keysight (Agilent) 66321B

Repair Form Keysight (Agilent) 66321B
Maximum file size: 40MB

No Related Posts

More Information
Model66321B

The Keysight (Agilent) 66321B Mobile Communications DC Source delivers precision sourcing from 0 to 15 V and up to 3 A, with peak currents of 5 A for up to 7 ms. It features fast transient response (<20 µs), programmable output resistance, and a unique internal battery resistance simulation for robust testing of digital wireless communication devices. With voltage accuracy of 10 mV and current accuracy down to 2.5 µA, it ensures meticulous performance across modes.

Ideal for battery-powered device testing, it integrates an advanced measurement system for monitoring current drains and supports detection of open-sense wire issues, enhancing test reliability and system throughput.

Testwall can supply the used Keysight (Agilent) 66321B, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Keysight (Agilent) 66321B.

Clicky Copyright © 2025-present Magento, Inc. All rights reserved.