| Attribute | Value |
|---|---|
| Data Rate | Up to 32 Gb/s per lane |
| Number of Channels | 1 or 2 channels (configurable) |
| Jitter Injection | Sinusoidal jitter (SJ), random jitter (RJ), periodic jitter (PJ), and spread spectrum clocking (SSC) |
| De-Emphasis | 2-tap de-emphasis with up to -6 dB at full data rate |
| Output Voltage Swing | Up to 1.2 V peak-to-peak differential |
| Form Factor | AXIe module (1-slot, compatible with M9505A and M9502A AXIe chassis) |
| Interface/Standard Compliance | PCIe Gen 3, USB 3.1, SATA, SAS, 10GBASE-KR, and other high-speed serial standards |
| Clock Source | Internal reference clock or external reference clock input (100 MHz typical) |
| Operating Temperature | 0°C to 55°C |
| Software/Control Interface | Controlled via Keysight M8070A system software; supports SCPI and IVI-COM drivers |
Keysight (Agilent) M8061A Options:
- M8061A - 001 - Multiplexer 2:1 up to 28.4 Gb/s, 2-slot AXIe module
- M8061A - 004 - De-emphasis, 4 calibrated taps
- M8061A - 008 - De-emphasis, extension to 8 taps
- M8061A - BU2 - Bundle consisting of M9502A-U20 AXIe 2 slot chassis with USB option. Recommended for use with J-BERT N4903B
- M8061A - U04 - Upgrade to de-emphasis, 4 calibrated taps
- M8061A - U08 - Upgrade to de-emphasis extension to 8 taps
- M8061A - 801 - Matched cable kit for connecting M8061A with J-BERT N4903B (required)
- M8061A - 802 - Band pass filter 11.4 to 15.6 GHz, SMA (for use with M8020A and M8061A in clock path to minimize intrinsic RJ of M8061A for data rate of 25.78 Gb/s)
- M8061A - 803 - Band pass filter 11.1 to 17.5 GHz, SMA (for use with M8020A and M8061A in clock path to minimize intrinsic RJ of M8061A for data rates from 25.0 to 32.0 Gb/s)
- M8061A - 804 - Cable kit for connecting M8061A with J-BERT M8020A, 3 x 3.5 mm, 0.6 m (required)
| Model | M8061A |
|---|
The Keysight (Agilent) M8061A Multiplexer 2:1 extends the data rate capability of J-BERT M8020A up to 32 Gb/s and J-BERT N4903B up to 28.4 Gb/s. It includes internal interference superposition, Clock/2 jitter injection, and optional up to 8-tap de-emphasis for advanced signal conditioning. This 2-slot AXIe module is fully controllable from J-BERT user interfaces via USB, offering transparent jitter performance and electrical idle support.
Ideal for testing serial interfaces, optical transceivers (100GBASE-LR4/SR4/ER4), SERDES, and high-speed chip-to-chip links like OIF CEI, and 100GBASE backplanes or cables.
Testwall can supply the used Keysight (Agilent) M8061A Multiplexer 2:1 With De-Emphasis 32 Gb/s, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Keysight (Agilent) M8061A Multiplexer 2:1 With De-Emphasis 32 Gb/s.