Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) N5249B

PNA-X Microwave Network Analyzer, 8.5 GHz
10 MHz to 50 GHz Frequency Range
4 Number of Ports
Up to 122 dB Dynamic Range
-85 dBm to +10 dBm Output Power Range
0.004 dB RMS at 10 Hz IF bandwidth Trace Noise (Typical)
Request datasheet
Attribute Value
Frequency Range 10 MHz to 50 GHz
Number of Ports 4
Dynamic Range Up to 122 dB
Output Power Range -85 dBm to +10 dBm
Trace Noise (Typical) 0.004 dB RMS at 10 Hz IF bandwidth
Test Port Connector Type 2.4 mm (f)
IF Bandwidth Range 1 Hz to 15 MHz
Measurement Parameters S-parameters, Z-parameters, Y-parameters, H-parameters, group delay, impedance
Power Supply 100–240 VAC, 50/60 Hz
Operating Temperature Range 0°C to 55°C
Keysight (Agilent) N5249B Options:
  • N5249B - 029 - Adds hardware and firmware for high-accuracy noise figure measurements (requires option 219, 222, 224, 419, 422, or 423)
  • N5249B - 201 - 2-port standard test set (includes six front-panel access loops) and power range
  • N5249B - 217 - 2-port standard test set (includes six front-panel access loops), power range, and source and receiver attenuators (extended power range)
  • N5249B - 219 - 2-port standard test set (includes six front-panel access loops), power range, source and receiver attenuators (extended power range), and bias-tees
  • N5249B - 222 - 2-port standard test set (includes six front-panel access loops), power range, source and receiver attenuators (extended power range), internal second source, a combiner, and mechanical switches
  • N5249B - 224 - 2-port standard test set (includes six front-panel access loops), power range, source and receiver attenuators (extended power range), internal second source, a combiner, mechanical switches, and bias tees
  • N5249B - 401 - 4-port standard test set (includes twelve front-panel access loops), power range, and an internal second source (Option 080 recommended)
  • N5249B - 417 - 4-port standard test set (includes twelve front-panel access loops), power range, internal second source (Option 080 recommended), and source and receiver attenuators (extended power range)
  • N5249B - 419 - 4-port standard test set (includes twelve front-panel access loops), power range, internal second source (Option 080 recommended), source and receiver attenuators (extended power range), and bias-tees
  • N5249B - 422 - 4-port standard test set (includes six front-panel access loops), power range, source and receiver attenuators (extended power range), internal second source, a combiner, and mechanical switches
  • N5249B - 423 - 4-port standard test set (includes six front-panel access loops), power range, source and receiver attenuators (extended power range), internal second source, a combiner, mechanical switches, and bias tees
Calibration Form Keysight (Agilent) N5249B

Repair Form Keysight (Agilent) N5249B
Maximum file size: 40MB

No Related Posts

More Information
ModelN5249B

The Keysight (Agilent) N5249B PNA-X is an advanced microwave network analyzer featuring dual internal signal sources, signal combiner, pulse modulators, S-parameter and noise receivers, and RF access points. Designed for testing amplifiers, mixers, and converters, it enables comprehensive linear and nonlinear device analysis.

This all-in-one solution reduces setup complexity and test time with a multitouch interface and the widest range of measurement applications in RF testing.

Testwall can supply the used Keysight (Agilent) N5249B, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Keysight (Agilent) N5249B.

Clicky Copyright © 2025-present Magento, Inc. All rights reserved.