Megger (AVO Biddle)

Megger MTO250

50A Transformer Ohmmeter
10 V to 250 V AC Test Voltage Range
15 Hz to 400 Hz Frequency Range
0.1 mΩ to 2000 Ω Measurement Range
50 A Maximum Test Current
±0.5% of reading ±0.1 mΩ Accuracy
Request datasheet
Attribute Value
Test Voltage Range 10 V to 250 V AC
Frequency Range 15 Hz to 400 Hz
Measurement Range 0.1 mΩ to 2000 Ω
Maximum Test Current 50 A
Accuracy ±0.5% of reading ±0.1 mΩ
Display Backlit graphical LCD
Memory Storage Up to 400 test results
Power Supply 115/230 V AC, 50/60 Hz
Communication Interface USB and RS-232
Operating Temperature -10°C to 50°C (14°F to 122°F)
Megger MTO250 Options:
  • MTO250 - 2005-340 - Transit case
  • MTO250 - 1004-639 - HV strobe, complete with 60 ft (18 m) lead
  • MTO250 - 1007-502 - Remote tap controller model RTC-1
  • MTO250 - 1006-512-1 - Test shunt, 50 A, 2 mW
  • MTO250 - 1006-512-2 - Test shunt, 10 A, 10 mW
  • MTO250 - 1004-640 - Lead set, 30 ft (9 m), [150 kV] complete with current lead set, V1 potential lead set, V2 potential lead set, current shorting lead
  • MTO250 - 2000-787-30 - Current lead set, 30 ft (9 m)
  • MTO250 - 2000-700-30 - V1 potential lead set, 30 ft (9 m)
  • MTO250 - 2000-701-30 - V2 potential lead set, 30 ft (9 m)
  • MTO250 - 2000-788-15 - Current shorting lead, 15 ft (4.5 m)
  • MTO250 - 1004-641 - Lead set, 60 ft (18 m), [500 kV] complete with current lead set, V1 potential lead set, V2 potential lead set, current shorting lead
  • MTO250 - 2000-787-60 - Current lead set, 60 ft (18 m)
  • MTO250 - 2000-700-60 - V1 potential lead set, 60 ft (18 m)
  • MTO250 - 2000-701-60 - V2 potential lead set, 60 ft (18 m)
  • MTO250 - 2000-788-30 - Current shorting lead, 30 ft (9 m)
  • MTO250 - 1004-642 - Lead set, 100 ft (30 m), [750 kV] complete with current lead set, V1 potential lead set, V2 potential lead set, current shorting lead
  • MTO250 - 2000-787-100 - Current lead set, 100 ft (30 m)
  • MTO250 - 2000-700-100 - V1 potential lead set, 100 ft (30 m)
  • MTO250 - 2000-701-100 - V2 potential lead set, 100 ft (30 m)
  • MTO250 - 2000-788-50 - Current shorting lead, 50 ft (15 m)
  • MTO250 - 2000-789-30 - 1 set current+potential leads (Kelvin Lead Set), 30 ft (9 m) [150 kV]
  • MTO250 - 2000-789-60 - 1 set current+potential leads (Kelvin Lead Set), 60 ft (18 m) [500 kV]
  • MTO250 - 2000-789-100 - 1 set current+potential leads (Kelvin Lead Set), 100 ft (30 m) [750 kV]
  • MTO250 - 30915-220 - Remote Hand Switch
Calibration Form Megger MTO250

Repair Form Megger MTO250
Maximum file size: 40MB

No Related Posts

More Information
ModelMTO250

The Megger MTO250 50A Transformer Ohmmeter is a portable, line-operated device built for precise resistance testing of transformer, shunt reactor, and rotating machine windings. It supports dual potential inputs, allowing simultaneous measurement of primary and secondary windings. With a DC test current up to 50A, it minimizes test times significantly compared to standard 10A instruments. Additional features include guided setups, automated heat run testing, and integrated data storage for nine test groups.

Engineered for efficient diagnostics, the Megger MTO250 is ideal for assessing winding and contact resistance in LTCs, detecting transition events such as contact wear, weak springs, and misalignment. Dual injection readings ensure timely and reliable testing in demanding field conditions.

Testwall can supply the used Megger MTO250, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Megger MTO250.