Pacific Power 3060-MS

| Attribute | Value |
|---|---|
| Output Voltage Range | 0 to 300 VAC (single phase), programmable |
| Output Frequency Range | 45 Hz to 500 Hz, programmable |
| Power Rating | 6000 VA (6 kVA) |
| Number of Phases | Single Phase Output |
| Input Voltage | 105–125 VAC / 210–250 VAC, 50/60 Hz |
| Voltage Regulation | ±0.1% of full scale |
| Total Harmonic Distortion (THD) | Less than 0.5% at full linear load |
| Output Current (Max) | 20 A RMS continuous |
| Control Interface | Front panel digital controls with RS-232 and IEEE-488 (GPIB) remote interface |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
Pacific Power 3060-MS Options:
- 3060-MS - /CE - CE Mark. Includes Output Circuit Breaker (/OCB)
- 3060-MS - /CSTB - Casters
- 3060-MS - /OCB - Output Circuit Breaker
- 3060-MS - /M99575 - Split Phase Output Configurations (50 kW)
- 3060-MS - /M99583 - Split Phase Output Configurations (32 kW)
- 3060-MS - /G - GPIB Interface, SCPI Commands & IEEE488.2 (standard)
- 3060-MS - /S - RS232 Interface, SCPI Commands, Baudrate up to 38.4 kBps (Replaces GPIB, no cost option)
- 3060-MS - UPC-Studio - Windows AC Power Source Control Software (no cost option)
- 3060-MS - ABD0100 - License for Avionics Test Sequences according to norm ABD0100.8.1. Requires UPC-Test Manager Option
- 3060-MS - A350 - License for Avionics Test Sequences according to norm Airbus A350. Requires UPC-Test Manager Option
- 3060-MS - DO160 - License for Avionics Test Sequences according to norm DO160 Version E. Requires UPC-Test Manager Option
- 3060-MS - IEC-AC-4XX - IEC 61000-4 AC Immunity Test Sequences. Includes 4-11, 4-14, 4-27, 4-28 and 4-34. Excludes 4-13 Option
- 3060-MS - SCU/UPC32-413 - IEC 61000-4-13 Inter Harmonic Generator. Required to run 4-13 tests. Includes 4-13 software
- 3060-MS - UMS - Battery Backup Option; converts 3060-MS to an Uninterruptible Power Source (UPS)
| Model | 3060-MS |
|---|
The Pacific Power 3060-MS is a high-power solid-state frequency converter with a 62.5 kVA, 3-phase AC Power Source. It rectifies AC to DC with minimal distortion, then converts back to AC using a PWM switchmode inverter, delivering exceptional stability and reliability.
It supports testing for voltage dips, fluctuations, and transformer performance with outputs up to 600V L-L and 350 Amps per phase. Variable frequency operation from 47–500 Hz and fixed modes of 50, 60, or 400 Hz make it versatile for demanding applications.
Testwall can supply the used Pacific Power 3060-MS, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Pacific Power 3060-MS.