Tektronix TDP3500

Sonda różnicowa, 3,5 GHz

Producent:
Model: Tektronix TDP3500
Opis: Sonda różnicowa, 3,5 GHz
Arkusz danych PDF: Tektronix TDP3500

Tektronix TDP3500 Diffeial Probe, 1.5 GHzThe Tektronix TDP3500 Probe is a Diffeial-ended Active probe that provides truer signal reproduction and fidelity for high-frequency measurements. It also provides high-speed electrical and mechanical performance required for today’s digital system designs. The Tektronix TDP3500 Probe is designed specifically for use, and direct connection to, Tektronix Oscilloscopes with the TekVPI™ probe interface.Features and Specifications of the TDP3500 Diffeial Probe include:

  • Features:
    • Outstanding electrical performance:
      • Bandwidth that provides accurate measurements for serial and digital applications
      • Excellent common mode rejection that reduces measurement errors in higher common environments
      • Low capacitive and resistive loading:
        • Maintains signal fidelity
        • Reduces DC biasing interactions
    • Versatile mechanical performance:
      • Compact probe head size for probing small geometry circuit elements
      • DUT attachment accessories enable connection to fine-spaced SMDs
      • Robust design for reliability
    • Connects directly to Oscilloscope with the TekVPI™ probe interface
    • Provides automatic units scaling and readout on the Oscilloscope display
    • Embeds the probe characteristics within the Oscilloscope
    • Easy access to probe comp box controls or Oscilloscope probe menu display for:
      • probe status
      • probe setup control
      • diagnostic information
    • Integrated Scope/Probe System:
      • Direct connection to and powered from the TekVPI™ Oscilloscope Interface without the need of an external power supply
      • Single-button Oscilloscope probe menu access
      • Setup and control from comp box or Oscilloscope user interface
      • AutoZero:  Zeros out output offset
      • Remote GPIB/USB probe control through the Oscilloscope
    • Applications:
      • Design, validation, degugging, and characterization of common high-speed serial bus designs:
        • I2C
        • CAN/LIN
        • SPI
        • Serial ATA
        • Ethernet (GbE)
        • USB 2.0
        • Firewire (1394b)
      • Signal integrity, jitter, and timing analysis
      • Manufacturing, engineering and test
  • Specifications:
    • Probe Bandwidth:  ≥3.5 GHz warranted
    • Probe Attenuation:  5x
    • Probe Rise Time:  ≤110 ps typical
    • Diffeial Input Capacitance:  ≤0.3 pF
    • Diffeial Input Resistance:  100 kΩ
    • Diffeial Input Dynamic Range:  ±2 V
    • CMRR:
      • >60 dB at 1 MHz
      • >25 dB at 1 GHz
    • Input Offset Range: ±1 V displayed
    • Operation Voltage Input Range (Common Mode Input Range):  +5 V to -4V
    • Noise:  ≈35 nV/root Hz
    • Max Input Voltage (Nondestruct):  ±15 V (DC + pk AC)
    • Propagation Delay:  5.4 ns typical
  • Outstanding electrical performance:
    • Bandwidth that provides accurate measurements for serial and digital applications
    • Excellent common mode rejection that reduces measurement errors in higher common environments
    • Low capacitive and resistive loading:
      • Maintains signal fidelity
      • Reduces DC biasing interactions
  • Versatile mechanical performance:
    • Compact probe head size for probing small geometry circuit elements
    • DUT attachment accessories enable connection to fine-spaced SMDs
    • Robust design for reliability
  • Connects directly to Oscilloscope with the TekVPI™ probe interface
  • Provides automatic units scaling and readout on the Oscilloscope display
  • Embeds the probe characteristics within the Oscilloscope
  • Easy access to probe comp box controls or Oscilloscope probe menu display for:
    • probe status
    • probe setup control
    • diagnostic information
  • Integrated Scope/Probe System:
    • Direct connection to and powered from the TekVPI™ Oscilloscope Interface without the need of an external power supply
    • Single-button Oscilloscope probe menu access
    • Setup and control from comp box or Oscilloscope user interface
    • AutoZero:  Zeros out output offset
    • Remote GPIB/USB probe control through the Oscilloscope
  • Applications:
    • Design, validation, degugging, and characterization of common high-speed serial bus designs:
      • I2C
      • CAN/LIN
      • SPI
      • Serial ATA
      • Ethernet (GbE)
      • USB 2.0
      • Firewire (1394b)
    • Signal integrity, jitter, and timing analysis
    • Manufacturing, engineering and test
  • Bandwidth that provides accurate measurements for serial and digital applications
  • Excellent common mode rejection that reduces measurement errors in higher common environments
  • Low capacitive and resistive loading:
    • Maintains signal fidelity
    • Reduces DC biasing interactions
  • Maintains signal fidelity
  • Reduces DC biasing interactions
  • Compact probe head size for probing small geometry circuit elements
  • DUT attachment accessories enable connection to fine-spaced SMDs
  • Robust design for reliability
  • probe status
  • probe setup control
  • diagnostic information
  • Direct connection to and powered from the TekVPI™ Oscilloscope Interface without the need of an external power supply
  • Single-button Oscilloscope probe menu access
  • Setup and control from comp box or Oscilloscope user interface
  • AutoZero:  Zeros out output offset
  • Remote GPIB/USB probe control through the Oscilloscope
  • Design, validation, degugging, and characterization of common high-speed serial bus designs:
    • I2C
    • CAN/LIN
    • SPI
    • Serial ATA
    • Ethernet (GbE)
    • USB 2.0
    • Firewire (1394b)
  • Signal integrity, jitter, and timing analysis
  • Manufacturing, engineering and test
  • I2C
  • CAN/LIN
  • SPI
  • Serial ATA
  • Ethernet (GbE)
  • USB 2.0
  • Firewire (1394b)
  • Probe Bandwidth:  ≥3.5 GHz warranted
  • Probe Attenuation:  5x
  • Probe Rise Time:  ≤110 ps typical
  • Diffeial Input Capacitance:  ≤0.3 pF
  • Diffeial Input Resistance:  100 kΩ
  • Diffeial Input Dynamic Range:  ±2 V
  • CMRR:
    • >60 dB at 1 MHz
    • >25 dB at 1 GHz
  • Input Offset Range: ±1 V displayed
  • Operation Voltage Input Range (Common Mode Input Range):  +5 V to -4V
  • Noise:  ≈35 nV/root Hz
  • Max Input Voltage (Nondestruct):  ±15 V (DC + pk AC)
  • Propagation Delay:  5.4 ns typical
  • >60 dB at 1 MHz
  • >25 dB at 1 GHz
  •       

    Tektronix