Keysight (Agilent) N6761A

Precision DC Power Module, 50V, 1.5A, 50W

Manufacturer:
Model: Keysight (Agilent) N6761A
Description: Precision DC Power Module, 50V, 1.5A, 50W
Data Sheet PDF: Keysight (Agilent) N6761A

The Keysight N6761A (Agilent) Precision DC Power Module provides precise control, low noise, and intricate measurements in the milliampere and microampere zones. This unit has the ability to simultaneously digitize voltage and cur, and capture those measurements in an Oscilloscope-like data buffer. Option 2UA can be added in order to measure (down to 1 μA) leakage cur or sleep-mode cur. (Option 2UA is a 200 microampere measurement range available on Agilent N6761A.)Features and Specifications of the Keysight N6761A (Agilent) Precision DC Power Module include:

  • Features:
    • 50 W output rating
    • Autoranging output capability
    • Voltage or cur turn-on priority
    • Precision voltage and cur measurements
    • Low voltage and cur output ranges
    • Low voltage and cur measurement ranges
    • Option 2UA, a 200 microampere measurement range, is available and includes Option 761
    • Simultaneous voltage and cur measurements
    • SCPI command output list capability (when using the remote interfaces only, not from the front panel)
    • SCPI command array readback (when using the remote interfaces only, not from the front panel)
    • SCPI command programmable sample rate  (when using the remote interfaces only, not from the front panel)
  • Specifications:
    • Output Ratings:
      • Voltage: 50 V
      • Cur: 1.5 A
      • Power: 50 W
    • Programming Accuracy (at 23ºC +5ºC)
      • Voltage high range: 0.016% + 6 mV
      • Voltage low range (≤ 5.5 V): 0.016% + 1.5 mV
      • Cur high range: 0.04% + 200 µA
      • Cur low range (≤ 100 mA, @ 0 – 7 V): 0.04% + 15 µA
    • Ripple & Noise (20 Hz to 20 MHz)
      • Voltage peak-to-peak: 4.5 mV
      • Voltage rms: 350 µV
      • Cur rms: 2 mA
  • 50 W output rating
  • Autoranging output capability
  • Voltage or cur turn-on priority
  • Precision voltage and cur measurements
  • Low voltage and cur output ranges
  • Low voltage and cur measurement ranges
  • Option 2UA, a 200 microampere measurement range, is available and includes Option 761
  • Simultaneous voltage and cur measurements
  • SCPI command output list capability (when using the remote interfaces only, not from the front panel)
  • SCPI command array readback (when using the remote interfaces only, not from the front panel)
  • SCPI command programmable sample rate  (when using the remote interfaces only, not from the front panel)
  • Output Ratings:
    • Voltage: 50 V
    • Cur: 1.5 A
    • Power: 50 W
  • Programming Accuracy (at 23ºC +5ºC)
    • Voltage high range: 0.016% + 6 mV
    • Voltage low range (≤ 5.5 V): 0.016% + 1.5 mV
    • Cur high range: 0.04% + 200 µA
    • Cur low range (≤ 100 mA, @ 0 – 7 V): 0.04% + 15 µA
  • Ripple & Noise (20 Hz to 20 MHz)
    • Voltage peak-to-peak: 4.5 mV
    • Voltage rms: 350 µV
    • Cur rms: 2 mA
  • Voltage: 50 V
  • Cur: 1.5 A
  • Power: 50 W
  • Voltage high range: 0.016% + 6 mV
  • Voltage low range (≤ 5.5 V): 0.016% + 1.5 mV
  • Cur high range: 0.04% + 200 µA
  • Cur low range (≤ 100 mA, @ 0 – 7 V): 0.04% + 15 µA
  • Voltage peak-to-peak: 4.5 mV
  • Voltage rms: 350 µV
  • Cur rms: 2 mA
  •       

    Keysight Agilent