Tektronix DPO7054C

Digital Phosphor Oscilloscope, 500 MHz 4 Ch., 20 GS/s

Manufacturer:
Model: Tektronix DPO7054C
Description: Digital Phosphor Oscilloscope, 500 MHz 4 Ch., 20 GS/s
Data Sheet PDF: Tektronix DPO7054C

Tektronix DPO7054C Oscilloscope (call for availability)The Tektronix DPO7054C Digital Phosphor Oscilloscope provides feature-packed tools to simplify operation and quickly diagnose and debug complex, mixed signal designs. The DPO7054C Oscilloscope’s high bandwidth helps achieve more accurate characterizations of designs by optimizing the oscillocope’s performance individually by channel. Its fast real-time sample rate improves design validation by accurately sampling signal to ensure all frequency content is being acquired and displayed. Wave Inspector® controls provide easy navigation and automated search of waveform data. The Tektronix DPO7054C has built-in analysis tools that provide 53 automated measurements including measurement statistics, histograms, advanced waveform math, user-definable filters, and custom MATLAB and .NET math plug-ins.Features and Specifications of the Tektronix DPO7054C Ditgital Phosphor Oscilloscope include:

  • Features:
    • Performance:
      • Up to 500 Megapoint Record Length with MultiView Zoom™
      • FastAcq™
        • provides >250,000 wfms/s maximum waveform capture rate
        • helps to quickly discover glitches, infrequent events, and elusive anomalies
      • FastFrame™ segmented memory acquisition mode with >310,000 Waveforms/s capture rate
      • User-selectable bandwidth limit filters for better low-frequency measurement accuracy
    • Ease-of-use Features:
      • Pinpoint® Triggering provides the most flexible and highest performance triggering with over 1400 available trigger combinations to address virtually any triggering situation
      • Optional Visual Trigger precisely quailfies triggers, finds unique events in complex wavefroms, and enables graphical trigger definition
      • Advanced search and mark to find specific events in the entire waveform
      • MyScope® custom control windows and right mouse click menus for exceptional efficiency
      • TekVPI™ Probe Interface supports active, diffeial, and cur probes for automatic scaling and units
      • Up to 40 GS/s and 400 Meg record length with options
      • 12.1″ (307 mm) bright XGA color display with touch screen
    • Connectivity:
      • USB Host Ports on the dront and side panels for quick and easy data storage, printing, and connecting USB peripherals
      • Integrated 10/100/1000BASE-T Ethernet Port for network connection and video out port to export the Oscilloscope display to a monitor or projector
      • Microsoft® Windows 7 64-bit operating system for easy connectivity and Integration into your environment
      • LXI Class C compliant
    • Optional Serial Triggering and Analysis:
      • Automated serial triggering, decode, and search options for I2C, SPI, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and USB 2.0
      • Automated serial analysis options for MIPI® D-PHY DSI-1 and CSI-2, 8b/10b, and PCI Express
      • Clock recovery from serial data streams
      • 64-bit NRZ serial pattern trigger for isolation of pattern-dependent effects up to 1.25 Gb/s
    • Optional Technology Specific Analysis:
      • Over 15 software solutions packages provide built-in domain expertise for MIPI® D-PHY, Ethernet, MOST, and USB 2.0 compliance testing, jitter, timing, eye diagrams, power, DDR memory bus analysis, and wideband RF
      • Limit and mask testing provide quick insight into signal characteristics
  • Specifications:
    • Vertical System Analog Channels:
      • Input channels:  4
      • Bandwidth:  500 MHz
      • Rise time 10% to 90% (typical):  460 ps
      • Rise Time 20% to 80 % (typical):  310 ps
      • DC Gain Accuracy:  ±1% with offset/position set to 0
      • Effective number of bits:  6.8 bits
      • Input Coupling:  AC, DC, GND
      • Input Inpedance:  1 MΩ ±1% with 13 pF ±2 pF, 50 Ω ±1%
      • Input Sensitivity:
        • MΩ: 1 mV/div to 10 V/div
        • 50 Ω: 1 mV/div to 1 V/div
      • Vertical Resolution:  8 bit (>11 bit with Hi Res)
      • Max Input Voltage, 1 MΩ:  ±150 V CAT I, derate at 20 dB/decade to 9 VRMS above 200 kHz
      • Max Input Voltage, 50 Ω:  5 VRMS, with peaks ≤ ±24 V
      • Position Range:  ±5 divisions
      • Delay between any 2 channels (typical):  ≤100 ps (50 Ω, DC coupling and equal V/div at or above 10 mV/div)
      • Offset Range:
        • 1 mV/div to 50 mV/div:  ±1 V
        • 50.5 mV/div to 99.5 mV/div:  ±(1.5 V – 10 divisions)
        • 100 mV/div to 500 mV/div:  ±10 V
        • 505 mV/div to 995 mV/div:  ±(15 V – 10 divisions)
        • 1 V/div to 5 V/div:  ±100 V
        • 5.05 V/div to 10 V/div:  ±(150 V – 10 divisions)
      • Channel-to-Channel Isolation (Any two channels at equal Vertical Scale settings) (Typical):
        • ≥100:1 at ≤100 MHz ≥30:1 between 100 MHz and 2.5 GHz ≥20:1 between 2.5 GHz and 3.5 GHz
    • Horizontal System Analog Channels:
      • Maximum sample rate (1 ch):  20 GS/s
      • Maximum sample rate (2 ch):  10 GS/s
      • Maximum sampe rate (3-4 ch):  5 GS/s
      • Maximum equivalent time sampling rate:  4 TS/s
      • Maximum record length with standard configuration:  50M (1 ch), 25M (2 ch), 12.5M (3-4 ch)
      • Maximum duration at highest real-time sample rate (1 ch):
        • 1-2 ms with standard record length
        • up to 10 ms with optional record length
      • Time base range:  1.25 ps/div to 1000 s/div
      • Time resolution (in ET / IT mode):  500 fs
      • Time base delay time range:  -10 divisions to 1000 s
      • Channel-to-channel deskew range:  ±75 ns
      • Delta time measurement accuracy:  ((0.06 / sample rate) + (2.5 ppm × Reading)) RMS
      • Trigger jitter (RMS):
        • 1.5 psRMS with enhanced triggering OFF
      • Jitter noise floor:
      • Time base accuracy:  ±2.5 ppm + aging
  • Performance:
    • Up to 500 Megapoint Record Length with MultiView Zoom™
    • FastAcq™
      • provides >250,000 wfms/s maximum waveform capture rate
      • helps to quickly discover glitches, infrequent events, and elusive anomalies
    • FastFrame™ segmented memory acquisition mode with >310,000 Waveforms/s capture rate
    • User-selectable bandwidth limit filters for better low-frequency measurement accuracy
  • Ease-of-use Features:
    • Pinpoint® Triggering provides the most flexible and highest performance triggering with over 1400 available trigger combinations to address virtually any triggering situation
    • Optional Visual Trigger precisely quailfies triggers, finds unique events in complex wavefroms, and enables graphical trigger definition
    • Advanced search and mark to find specific events in the entire waveform
    • MyScope® custom control windows and right mouse click menus for exceptional efficiency
    • TekVPI™ Probe Interface supports active, diffeial, and cur probes for automatic scaling and units
    • Up to 40 GS/s and 400 Meg record length with options
    • 12.1″ (307 mm) bright XGA color display with touch screen
  • Connectivity:
    • USB Host Ports on the dront and side panels for quick and easy data storage, printing, and connecting USB peripherals
    • Integrated 10/100/1000BASE-T Ethernet Port for network connection and video out port to export the Oscilloscope display to a monitor or projector
    • Microsoft® Windows 7 64-bit operating system for easy connectivity and Integration into your environment
    • LXI Class C compliant
  • Optional Serial Triggering and Analysis:
    • Automated serial triggering, decode, and search options for I2C, SPI, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and USB 2.0
    • Automated serial analysis options for MIPI® D-PHY DSI-1 and CSI-2, 8b/10b, and PCI Express
    • Clock recovery from serial data streams
    • 64-bit NRZ serial pattern trigger for isolation of pattern-dependent effects up to 1.25 Gb/s
  • Optional Technology Specific Analysis:
    • Over 15 software solutions packages provide built-in domain expertise for MIPI® D-PHY, Ethernet, MOST, and USB 2.0 compliance testing, jitter, timing, eye diagrams, power, DDR memory bus analysis, and wideband RF
    • Limit and mask testing provide quick insight into signal characteristics
  • Up to 500 Megapoint Record Length with MultiView Zoom™
  • FastAcq™
    • provides >250,000 wfms/s maximum waveform capture rate
    • helps to quickly discover glitches, infrequent events, and elusive anomalies
  • FastFrame™ segmented memory acquisition mode with >310,000 Waveforms/s capture rate
  • User-selectable bandwidth limit filters for better low-frequency measurement accuracy
  • provides >250,000 wfms/s maximum waveform capture rate
  • helps to quickly discover glitches, infrequent events, and elusive anomalies
  • Pinpoint® Triggering provides the most flexible and highest performance triggering with over 1400 available trigger combinations to address virtually any triggering situation
  • Optional Visual Trigger precisely quailfies triggers, finds unique events in complex wavefroms, and enables graphical trigger definition
  • Advanced search and mark to find specific events in the entire waveform
  • MyScope® custom control windows and right mouse click menus for exceptional efficiency
  • TekVPI™ Probe Interface supports active, diffeial, and cur probes for automatic scaling and units
  • Up to 40 GS/s and 400 Meg record length with options
  • 12.1″ (307 mm) bright XGA color display with touch screen
  • USB Host Ports on the dront and side panels for quick and easy data storage, printing, and connecting USB peripherals
  • Integrated 10/100/1000BASE-T Ethernet Port for network connection and video out port to export the Oscilloscope display to a monitor or projector
  • Microsoft® Windows 7 64-bit operating system for easy connectivity and Integration into your environment
  • LXI Class C compliant
  • Automated serial triggering, decode, and search options for I2C, SPI, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and USB 2.0
  • Automated serial analysis options for MIPI® D-PHY DSI-1 and CSI-2, 8b/10b, and PCI Express
  • Clock recovery from serial data streams
  • 64-bit NRZ serial pattern trigger for isolation of pattern-dependent effects up to 1.25 Gb/s
  • Over 15 software solutions packages provide built-in domain expertise for MIPI® D-PHY, Ethernet, MOST, and USB 2.0 compliance testing, jitter, timing, eye diagrams, power, DDR memory bus analysis, and wideband RF
  • Limit and mask testing provide quick insight into signal characteristics
  • Vertical System Analog Channels:
    • Input channels:  4
    • Bandwidth:  500 MHz
    • Rise time 10% to 90% (typical):  460 ps
    • Rise Time 20% to 80 % (typical):  310 ps
    • DC Gain Accuracy:  ±1% with offset/position set to 0
    • Effective number of bits:  6.8 bits
    • Input Coupling:  AC, DC, GND
    • Input Inpedance:  1 MΩ ±1% with 13 pF ±2 pF, 50 Ω ±1%
    • Input Sensitivity:
      • MΩ: 1 mV/div to 10 V/div
      • 50 Ω: 1 mV/div to 1 V/div
    • Vertical Resolution:  8 bit (>11 bit with Hi Res)
    • Max Input Voltage, 1 MΩ:  ±150 V CAT I, derate at 20 dB/decade to 9 VRMS above 200 kHz
    • Max Input Voltage, 50 Ω:  5 VRMS, with peaks ≤ ±24 V
    • Position Range:  ±5 divisions
    • Delay between any 2 channels (typical):  ≤100 ps (50 Ω, DC coupling and equal V/div at or above 10 mV/div)
    • Offset Range:
      • 1 mV/div to 50 mV/div:  ±1 V
      • 50.5 mV/div to 99.5 mV/div:  ±(1.5 V – 10 divisions)
      • 100 mV/div to 500 mV/div:  ±10 V
      • 505 mV/div to 995 mV/div:  ±(15 V – 10 divisions)
      • 1 V/div to 5 V/div:  ±100 V
      • 5.05 V/div to 10 V/div:  ±(150 V – 10 divisions)
    • Channel-to-Channel Isolation (Any two channels at equal Vertical Scale settings) (Typical):
      • ≥100:1 at ≤100 MHz ≥30:1 between 100 MHz and 2.5 GHz ≥20:1 between 2.5 GHz and 3.5 GHz
  • Horizontal System Analog Channels:
    • Maximum sample rate (1 ch):  20 GS/s
    • Maximum sample rate (2 ch):  10 GS/s
    • Maximum sampe rate (3-4 ch):  5 GS/s
    • Maximum equivalent time sampling rate:  4 TS/s
    • Maximum record length with standard configuration:  50M (1 ch), 25M (2 ch), 12.5M (3-4 ch)
    • Maximum duration at highest real-time sample rate (1 ch):
      • 1-2 ms with standard record length
      • up to 10 ms with optional record length
    • Time base range:  1.25 ps/div to 1000 s/div
    • Time resolution (in ET / IT mode):  500 fs
    • Time base delay time range:  -10 divisions to 1000 s
    • Channel-to-channel deskew range:  ±75 ns
    • Delta time measurement accuracy:  ((0.06 / sample rate) + (2.5 ppm × Reading)) RMS
    • Trigger jitter (RMS):
      • 1.5 psRMS with enhanced triggering OFF
    • Jitter noise floor:
    • Time base accuracy:  ±2.5 ppm + aging
  • Input channels:  4
  • Bandwidth:  500 MHz
  • Rise time 10% to 90% (typical):  460 ps
  • Rise Time 20% to 80 % (typical):  310 ps
  • DC Gain Accuracy:  ±1% with offset/position set to 0
  • Effective number of bits:  6.8 bits
  • Input Coupling:  AC, DC, GND
  • Input Inpedance:  1 MΩ ±1% with 13 pF ±2 pF, 50 Ω ±1%
  • Input Sensitivity:
    • MΩ: 1 mV/div to 10 V/div
    • 50 Ω: 1 mV/div to 1 V/div
  • Vertical Resolution:  8 bit (>11 bit with Hi Res)
  • Max Input Voltage, 1 MΩ:  ±150 V CAT I, derate at 20 dB/decade to 9 VRMS above 200 kHz
  • Max Input Voltage, 50 Ω:  5 VRMS, with peaks ≤ ±24 V
  • Position Range:  ±5 divisions
  • Delay between any 2 channels (typical):  ≤100 ps (50 Ω, DC coupling and equal V/div at or above 10 mV/div)
  • Offset Range:
    • 1 mV/div to 50 mV/div:  ±1 V
    • 50.5 mV/div to 99.5 mV/div:  ±(1.5 V – 10 divisions)
    • 100 mV/div to 500 mV/div:  ±10 V
    • 505 mV/div to 995 mV/div:  ±(15 V – 10 divisions)
    • 1 V/div to 5 V/div:  ±100 V
    • 5.05 V/div to 10 V/div:  ±(150 V – 10 divisions)
  • Channel-to-Channel Isolation (Any two channels at equal Vertical Scale settings) (Typical):
    • ≥100:1 at ≤100 MHz ≥30:1 between 100 MHz and 2.5 GHz ≥20:1 between 2.5 GHz and 3.5 GHz
  • MΩ: 1 mV/div to 10 V/div
  • 50 Ω: 1 mV/div to 1 V/div
  • 1 mV/div to 50 mV/div:  ±1 V
  • 50.5 mV/div to 99.5 mV/div:  ±(1.5 V – 10 divisions)
  • 100 mV/div to 500 mV/div:  ±10 V
  • 505 mV/div to 995 mV/div:  ±(15 V – 10 divisions)
  • 1 V/div to 5 V/div:  ±100 V
  • 5.05 V/div to 10 V/div:  ±(150 V – 10 divisions)
  • ≥100:1 at ≤100 MHz ≥30:1 between 100 MHz and 2.5 GHz ≥20:1 between 2.5 GHz and 3.5 GHz
  • Maximum sample rate (1 ch):  20 GS/s
  • Maximum sample rate (2 ch):  10 GS/s
  • Maximum sampe rate (3-4 ch):  5 GS/s
  • Maximum equivalent time sampling rate:  4 TS/s
  • Maximum record length with standard configuration:  50M (1 ch), 25M (2 ch), 12.5M (3-4 ch)
  • Maximum duration at highest real-time sample rate (1 ch):
    • 1-2 ms with standard record length
    • up to 10 ms with optional record length
  • Time base range:  1.25 ps/div to 1000 s/div
  • Time resolution (in ET / IT mode):  500 fs
  • Time base delay time range:  -10 divisions to 1000 s
  • Channel-to-channel deskew range:  ±75 ns
  • Delta time measurement accuracy:  ((0.06 / sample rate) + (2.5 ppm × Reading)) RMS
  • Trigger jitter (RMS):
    • 1.5 psRMS with enhanced triggering OFF
  • Jitter noise floor:
  • Time base accuracy:  ±2.5 ppm + aging
  • 1-2 ms with standard record length
  • up to 10 ms with optional record length
  • 1.5 psRMS with enhanced triggering OFF
  •     

    Tektronix

    Tektronix DPO7054C Product Overview