Tektronix DPO4102B-L Oscilloscope (call for availability)The Tektronix DPO4102B-L Digital Phosphor Oscilloscope provides feature-packed tools to simplify operation and quickly diagnose and debug complex designs. With a single instrument up to 20 analog and digital signals can be analyzed, high bandwidth provides for seeing dynamic signal details and deep record length on all channels allows for capturing long periods of signal activity. Wave Inspector® controls provide easy navigation and automated search of waveform data.Features and Specifications of the Tektronix DPO4102B-L Digital Phosphor Oscilloscope include:
Features:
Key Features:
Wave Inspector® controls provide easy navigation and automated search of waveform data
41 automated measurements
FFT analysis for simplified waveform analysis
Optional serial triggering and analysis: Automated serial triggering, decode, and search options for I2C, SPI, USB, Ethernet, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and I2S/LJ/RJ/TDM
TekVPI® probe interface supports active, diffeial, and cur probes for automatic scaling and units
Suite of advanced triggers
10.4 in. (264 mm) Bright XGA color display
Small footprint and lightweight – Only 5.8 in. (147 mm) deep and 11 lb. (5 kg)
Plug-and-Play connectivity and analysis solutions
Connectivity:
Two USB 2.0 host ports on the front panel and two on the rear panel for:
quick and easy data storage
printing
connecting a USB keyboard
USB 2.0 device port on rear panel for:
easy connection to a PC
direct printing to a PictBridge®-compatible printer
Integrated 10/100/1000BASE-T Ethernet port for network connection and video out port to export the Oscilloscope display to a monitor or projector
Optional Application Support:
Power analysis
LImit mask testing
HDTV and custom video analysis
Specifications:
Model Overview:
Analog Channels: 2
Bandwidth: 1 GHz
Rise time: 350 ps
Sample rate: (1 ch): 5 GS/s
Sample rate: (2 ch): 2.5 GS/s
Record length: (1 ch): 5M
Record length: (2 ch): 5M
Duration at highest sample rate: 1 ms
Vertical System Analog Channels:
Hardware bandwidth limits: 20 MHz or 250 MHz
Input coupling: AC, DC
Input impedance: 1 MΩ ±1%, 50 Ω ±1%
Input sensitivity range:
1 MΩ: 1 mV/div to 10 V/div
50 Ω: 1 mV/div to 1 V/div
Vertical resolution: 8 bits (11 bits with Hi Res)
Maximum input voltage:
1 MΩ: 300 VRMS CAT II with peaks ≤ ±425 V
50 Ω: 5 VRMS with peaks ≤ ±20 V
DC gain accuracy: ±1.5%, derated at 0.10%/°C above 30 °C
Channel-to-channel isolation: Any two channels at equal vertical scale ≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated bandwidth
Horizontal System Analog Channels:
Time base range: 1 ns to 1000 s
Time-base delay time range: -10 divisions to 5000 s
Channel-to-channel deskew range: ±125 ns
Time base accuracy: ±5 ppm over any ≥1 ms interval
Key Features:
Wave Inspector® controls provide easy navigation and automated search of waveform data
41 automated measurements
FFT analysis for simplified waveform analysis
Optional serial triggering and analysis: Automated serial triggering, decode, and search options for I2C, SPI, USB, Ethernet, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and I2S/LJ/RJ/TDM
TekVPI® probe interface supports active, diffeial, and cur probes for automatic scaling and units
Suite of advanced triggers
10.4 in. (264 mm) Bright XGA color display
Small footprint and lightweight – Only 5.8 in. (147 mm) deep and 11 lb. (5 kg)
Plug-and-Play connectivity and analysis solutions
Connectivity:
Two USB 2.0 host ports on the front panel and two on the rear panel for:
quick and easy data storage
printing
connecting a USB keyboard
USB 2.0 device port on rear panel for:
easy connection to a PC
direct printing to a PictBridge®-compatible printer
Integrated 10/100/1000BASE-T Ethernet port for network connection and video out port to export the Oscilloscope display to a monitor or projector
Optional Application Support:
Power analysis
LImit mask testing
HDTV and custom video analysis
Wave Inspector® controls provide easy navigation and automated search of waveform data
41 automated measurements
FFT analysis for simplified waveform analysis
Optional serial triggering and analysis: Automated serial triggering, decode, and search options for I2C, SPI, USB, Ethernet, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and I2S/LJ/RJ/TDM
TekVPI® probe interface supports active, diffeial, and cur probes for automatic scaling and units
Suite of advanced triggers
10.4 in. (264 mm) Bright XGA color display
Small footprint and lightweight – Only 5.8 in. (147 mm) deep and 11 lb. (5 kg)
Plug-and-Play connectivity and analysis solutions
Two USB 2.0 host ports on the front panel and two on the rear panel for:
quick and easy data storage
printing
connecting a USB keyboard
USB 2.0 device port on rear panel for:
easy connection to a PC
direct printing to a PictBridge®-compatible printer
Integrated 10/100/1000BASE-T Ethernet port for network connection and video out port to export the Oscilloscope display to a monitor or projector
quick and easy data storage
printing
connecting a USB keyboard
easy connection to a PC
direct printing to a PictBridge®-compatible printer
Power analysis
LImit mask testing
HDTV and custom video analysis
Model Overview:
Analog Channels: 2
Bandwidth: 1 GHz
Rise time: 350 ps
Sample rate: (1 ch): 5 GS/s
Sample rate: (2 ch): 2.5 GS/s
Record length: (1 ch): 5M
Record length: (2 ch): 5M
Duration at highest sample rate: 1 ms
Vertical System Analog Channels:
Hardware bandwidth limits: 20 MHz or 250 MHz
Input coupling: AC, DC
Input impedance: 1 MΩ ±1%, 50 Ω ±1%
Input sensitivity range:
1 MΩ: 1 mV/div to 10 V/div
50 Ω: 1 mV/div to 1 V/div
Vertical resolution: 8 bits (11 bits with Hi Res)
Maximum input voltage:
1 MΩ: 300 VRMS CAT II with peaks ≤ ±425 V
50 Ω: 5 VRMS with peaks ≤ ±20 V
DC gain accuracy: ±1.5%, derated at 0.10%/°C above 30 °C
Channel-to-channel isolation: Any two channels at equal vertical scale ≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated bandwidth
Horizontal System Analog Channels:
Time base range: 1 ns to 1000 s
Time-base delay time range: -10 divisions to 5000 s
Channel-to-channel deskew range: ±125 ns
Time base accuracy: ±5 ppm over any ≥1 ms interval
If you are not completely satisfied with your purchase, simply return the item to us in its original condition within 30 days of receipt.
Returned items should be unused and must be returned in original packaging with any enclosed documentation. We will issue a full refund on receipt, excluding the original delivery charge. Alternatively, if preferred, we will exchange the item.
VAT