Teseq (Schaffner)

Teseq (Schaffner) NSG 3040

Test System for Surge Combination Wave, EFT/Burst, Dips Interrupts & Variations
Up to 4.4 kV peak Output Voltage Range
IEC 61000-4-5 combination wave (1.2/50 µs voltage, 8/20 µs current) Pulse Waveform
2 Ω and 12 Ω selectable Output Impedance
Line-to-line and line-to-earth coupling Coupling Modes
IEC 61000-4-5 Surge Immunity Testing Applicable Standard
Request datasheet
Attribute Value
Output Voltage Range Up to 4.4 kV peak
Pulse Waveform IEC 61000-4-5 combination wave (1.2/50 µs voltage, 8/20 µs current)
Output Impedance 2 Ω and 12 Ω selectable
Coupling Modes Line-to-line and line-to-earth coupling
Applicable Standard IEC 61000-4-5 Surge Immunity Testing
Repetition Rate At least 1 pulse per minute
Polarity Positive and Negative
Coupling/Decoupling Network Integrated CDN for single-phase and three-phase AC lines
Interface / Control RS-232 serial interface for remote control and automation
Power Supply Input 115/230 VAC, 50/60 Hz
Teseq (Schaffner) NSG 3040 Options:
  • NSG 3040 - CDN 8014/8015 - Capacitive coupling clamp for burst
  • NSG 3040 - CDN 163 - Burst coupling network 100 A per phase (coupling all to ref ground)
  • NSG 3040 - CDN 117/118 - Coupling networks for signal-/data lines (surge)
  • NSG 3040 - CAS 3025 - Burst/EFT verification set
  • NSG 3040 - MD 200 - Voltage differential probe 7 kV
  • NSG 3040 - MD 300 - Current probe 5 kA
  • NSG 3040 - INA 165 - Conducted stand-off
  • NSG 3040 - INA 166 - Brackets 5 HU for rack mounting
  • NSG 3040 - INA 6501 - Manual step transformer, 16 AAC, 0/40/70/80%
  • NSG 3040 - INA 6502 - Automatic step transformer, 16 AAC, 0/40/70/80%
  • NSG 3040 - VAR 6501 - Automatic variable transformer, 7.5 A
  • NSG 3040 - VAR 6502 - Automatic variable transformer, 2 x 16 A
  • NSG 3040 - VAR 6503 - Manual variable transformer, 7.5 A
  • NSG 3040 - MFO 6501 - Manual magnetic field option -4-8
  • NSG 3040 - MFO 6502 - Automatic magnetic field option -4-8
  • NSG 3040 - INA 701 - Magnetic field coil 1 x 1 m; with MFO max. 3.6 A/m -4-8; Surge max. 1200 A/m -4-9
  • NSG 3040 - INA 702 - Magnetic field coil 1 x 1 m; with MFO max. 40 A/m -4-8; Surge max. 1200 A/m -4-9
  • NSG 3040 - INA 753 - Pulse shape adapter
Calibration Form Teseq (Schaffner) NSG 3040

Repair Form Teseq (Schaffner) NSG 3040
Maximum file size: 40MB

No Related Posts

More Information
ModelNSG 3040

The Teseq Schaffner NSG 3040 is a multifunctional immunity generator designed to simulate EFT/Burst, surge, and voltage variations across electronic devices. It complies with IEC/EN 61000-4-4 (EFT/Burst), 61000-4-5 (Surge), 61000-4-11, and 61000-4-29 standards, ensuring robust pre-compliance testing. With its integrated CDN, the NSG 3040 supports up to 264 V and 16 A, making it versatile for demanding setups in product development environments.

This generator enables engineers to conduct precise immunity tests for both transient and surge events in a single unit, reducing equipment complexity while maintaining accuracy and compliance in validation processes.

Testwall can supply the used Teseq Schaffner NSG 3040, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Teseq Schaffner NSG 3040.

Clicky Copyright © 2025-present Magento, Inc. All rights reserved.