Teseq (Schaffner)

Teseq (Schaffner) NSG4070

Conducted RF Immunity Test System
9 kHz – 30 MHz Frequency Range
Up to 10 kV peak Output Voltage
Up to 200 A peak Output Current
Burst, continuous sine, damped oscillatory wave Waveform Types
IEC 61000-4-10, IEC 61000-4-18, MIL-STD-461 Compliance Standards
Request datasheet
Attribute Value
Frequency Range 9 kHz – 30 MHz
Output Voltage Up to 10 kV peak
Output Current Up to 200 A peak
Waveform Types Burst, continuous sine, damped oscillatory wave
Compliance Standards IEC 61000-4-10, IEC 61000-4-18, MIL-STD-461
Output Impedance 50 Ω
Control Interface USB, GPIB, RS-232
Power Supply 100–240 V AC, 50/60 Hz
Operating Temperature 0°C to 40°C
Dimensions (W x H x D) 425 mm x 177 mm x 500 mm
Teseq (Schaffner) NSG4070 Options:
  • NSG4070 - NSG4070C-0 - Compact immunity test system 4 kHz to 1 GHz RF generator and power meter (without power amplifier)
  • NSG4070 - NSG4070C-35 - Compact immunity test system, 4 kHz to 1 GHz RF generator and power meter (with 35 W module 150 kHz to 230 MHz)
  • NSG4070 - NSG4070C-40 - Compact immunity test system, 4 kHz to 1 GHz RF generator and power meter (with 40 W module 10 kHz to 400 MHz)
  • NSG4070 - NSG4070C-45 - Compact immunity test system, 4 kHz to 1 GHz RF generator and power meter (with 45 W module 9 kHz to 1 GHz)
  • NSG4070 - NSG4070C-60 - Compact immunity test system, 4 kHz to 1 GHz RF generator, 4 kHz to 1 GHz 5-channel power meter (3 inputs, 2 used internal), 60 W power amplifier module 10 kHz to 400 MHz (>10 W 4 to 10 kHz)
  • NSG4070 - NSG4070C-80 - Compact immunity test system, 4 kHz to 1 GHz RF generator and power meter (with 80 W module 150 kHz to 230 MHz)
  • NSG4070 - NSG4070-TC - Traceable calibration (ISO17025), order only with the device
  • NSG4070 - NSG4070-DAkkS - DAkkS calibration (ISO17025), order only with the device
  • NSG4070 - NSG4070 Rack (253840) - Rack mounting kit for NSG 4070 (red handles)
  • NSG4070 - SW4070 (253850) - Option for NSG 4070: RF-Switch network 2x SPDT
  • NSG4070 - LE4070 (253104) - RF cable set for NSG 4070
  • NSG4070 - ATN6060 (235380) - 6 dB Attenuator 60 W cw N(f)-N(f)
  • NSG4070 - ATN6150 (235376) - 6 dB Attenuator 150 W cw N(f)-N(f)
  • NSG4070 - ATN6200 (235378) - 6 dB Attenuator 200 W cw N(f)-N(f)
  • NSG4070 - icd.control (257512) - Software License for one generator NSG 4070B-xx, NSG 4070C-xx
Calibration Form Teseq (Schaffner) NSG4070

Repair Form Teseq (Schaffner) NSG4070
Maximum file size: 40MB

No Related Posts

More Information
ModelNSG4070

The Teseq NSG 4070 is a multifunctional EMC immunity test system covering a wide frequency range from 9 kHz to 1 GHz. It integrates a signal generator, three power meter inputs, and an internal amplifier module. With precise RF level resolution of 0.1 dB, fast 10 ms settling time, and advanced modulation options, the NSG 4070 is ideal for IEC 61000-4-6, BCI, and multiple immunity tests. The 5.7” TFT display and menu-based control software allow standalone operation, while remote control and USB data transfer ensure flexibility in test setups.

Applications include conducted immunity, radiated immunity, and shielding tests. The integrated amplifier ensures reliable performance up to 230 MHz, with power meter accuracy and multiple EUT monitoring options simplifying complex EMC testing scenarios across various standards.

Testwall can supply the used Teseq NSG 4070, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Teseq NSG 4070.

Clicky Copyright © 2025-present Magento, Inc. All rights reserved.