Keysight (Agilent)
Keysight (Agilent) E4443A
Spectrum Analyzer, 3 Hz - 6.7 GHz (PSA Series)
3 Hz – 6,7 GHz Rango de Frecuencia
-170 dBm a +30 dBm Rango de Amplitud
1 Hz – 8 MHz Ancho de Banda de Resolución (RBW)
-163 dBm/Hz (típico) Figura de Ruido Mostrada (DANL)
-114 dBc/Hz a 10 kHz de separación (típico) Fase de Ruido

| Atributo | Valor |
|---|---|
| Rango de Frecuencia | 3 Hz – 6,7 GHz |
| Rango de Amplitud | -170 dBm a +30 dBm |
| Ancho de Banda de Resolución (RBW) | 1 Hz – 8 MHz |
| Figura de Ruido Mostrada (DANL) | -163 dBm/Hz (típico) |
| Fase de Ruido | -114 dBc/Hz a 10 kHz de separación (típico) |
| Ancho de Banda de Vídeo (VBW) | 1 Hz – 50 MHz |
| Rango Dinámico | Hasta 78 dB (típico) |
| Precisión de Amplitud | ±0,19 dB (típico) |
| Impedancia de Entrada | 50 Ω |
| Interfaz y Conectividad | GPIB, LAN (10/100Base-T), RS-232, USB |
Keysight (Agilent) E4443A Options:
- E4443A - 1DS - RF internal preamplifier (100 kHz to 3 GHz)
- E4443A - 110 - RF/µW internal preamplifier (10 MHz to upper frequency limit of the PSA)
- E4443A - B7J - Digital demodulation hardware
- E4443A - 122 - 80 MHz bandwidth digitizer
- E4443A - 140 - 40 MHz bandwidth digitizer
- E4443A - 123 - Switchable MW preselector bypass
- E4443A - 124 - Y-axis video output
- E4443A - AYZ - External mixing
- E4443A - 107 - Audio input 100 kΩ
- E4443A - 111 - USB device side I/O interface
- E4443A - 115 - 512 MB user memory
- E4443A - 117 - Secure memory erase
- E4443A - H70 - 70 MHz IF output
- E4443A - HYX - 21.4 MHz IF output
- E4443A - 226 - Phase noise measurement personality
- E4443A - 219 - Noise figure measurement personality
- E4443A - 241 - Flexible digital modulation analysis personality
- E4443A - BAF - W-CDMA measurement personality
- E4443A - 210 - HSDPA/HSUPA (for W-CDMA) measurement personality
- E4443A - 202 - GSM w/ EDGE measurement personality
- E4443A - B78 - cdma2000 measurement personality
- E4443A - 214 - 1xEV-DV measurement personality
- E4443A - 204 - 1xEV-DO measurement personality
- E4443A - BAC - cdmaOne measurement personality
- E4443A - BAE - NADC, PCD measurement personality
- E4443A - 217 - WLAN measurement personality
- E4443A - 211 - TD-SCDMA power measurement personality
- E4443A - 212 - TD-SCDMA modulation personality
- E4443A - 213 - HSPA for TD-SCDMA personality
- E4443A - 215 - External source control personality
- E4443A - 266 - Programming code compatibility suite
- E4443A - 233 - Built-in measuring receiver personality
- E4443A - 23A - AM/FM/PM triggering
- E4443A - 23B - CCITT filter
- E4443A - 239 - N9039A RF preselector control
- E4443A - 230 - BenchLink Web Remote Control Software
- E4443A - 235 - Wide BW digitizer external calibration wizard
- E4443A - 0BW - Service manual
- E4443A - UK6 - Commercial calibration certificate with test data
- E4443A - A6J - Factory ANSI Z540 standard-compliant calibration
- E4443A - 1A7 - Factory ISO 17025 standard-compliant calibration
- E4443A - 1CM - Rack mount kit
- E4443A - 1CN - Front handle kit
- E4443A - 1CP - Rack mount with handles
- E4443A - 1CR - Rack slide kit
- E4443A - 015 - 6 GHz return loss measurement accessory kit
- E4443A - 045 - Millimeter wave accessory kit
- E4443A - 0B1 - Extra manual set including CD ROM
| Model | E4443A |
|---|
The Keysight E4443A (Agilent) PSA offers high-performance spectrum analysis, up to 6.7 GHz, with powerful one-button measurements, a versatile feature set, and a leading-edge combination of flexibility, speed, accuracy, analysis bandwidth, and dynamic range.
Other features and specifications include:
- Frequency range: 3 Hz - 6.7 GHz
- All-digital IF with auto-ranging capability
- Standard 10 MHz analysis bandwidth
- Optional 40 or 80 MHz analysis bandwidth to capture and measure complex signals
- -78 dB (nominal) third order intermodulation for 40 or 80 MHz analysis bandwidth
- Phase noise optimization
- Full detector suite
- 160 resolution bandwidth settings (10% steps)
- Typical Performance @ 1 GHz: Dynamic range (-155 dBm DANL, +19 dBm TOI, -118 dBc/Hz phase noise at 10 kHz offset; Accuracy ( ±0.19 dB absolute amplitude accuracy, ±0.11 dB frequency response)
- 2 dB step attenuator
- FFT and swept measurement modes
- Gated sweep
- Power Suite one-button power measurements
- EMI measurements with CISPR compliant bandwidths and detectors