Keysight (Agilent)
Keysight Technologies N9030B-544
44 GHz PXA Signal Analyzer, 2.4 mm (m)
3 Hz – 44 GHz Rango de frecuencia
-172 dBm/Hz (con preamplificador activado) Nivel de ruido mostrado promedio (DANL)
Hasta 78 dB Rango dinámico
-136 dBc/Hz a 10 kHz de separación (a 1 GHz) Fase de ruido
+30 dBm a -170 dBm Rango de amplitud

| Atributo | Valor |
|---|---|
| Rango de frecuencia | 3 Hz – 44 GHz |
| Nivel de ruido mostrado promedio (DANL) | -172 dBm/Hz (con preamplificador activado) |
| Rango dinámico | Hasta 78 dB |
| Fase de ruido | -136 dBc/Hz a 10 kHz de separación (a 1 GHz) |
| Rango de amplitud | +30 dBm a -170 dBm |
| Ancho de banda de análisis en tiempo real (RTSA) | Hasta 510 MHz |
| Resolución de ancho de banda (RBW) | 1 Hz – 50 MHz |
| Incertidumbre de nivel | ± 0,19 dB (típico) |
| Impedancia de entrada | 50 Ω |
| Conectores de entrada | Conector de entrada RF: 2,4 mm (m), compatible con 50 Ω |
Keysight Technologies N9030B-544 Options:
- N9030B-544 - P03 - Preamplifier, 100 kHz to 3.6 GHz
- N9030B-544 - P08 - Preamplifier, 100 kHz to 8.4 GHz
- N9030B-544 - P13 - Preamplifier, 100 kHz to 13.6 GHz
- N9030B-544 - P26 - Preamplifier, 100 kHz to 26.5 GHz
- N9030B-544 - P44 - Preamplifier, 100 kHz to 44 GHz
- N9030B-544 - EA3 - Electronic attenuator up to 3.6 GHz; 1 dB steps, 0 to 24 dB
- N9030B-544 - B40 - 40 MHz analysis bandwidth
- N9030B-544 - B85 - 85 MHz analysis bandwidth
- N9030B-544 - B1X - 160 MHz analysis bandwidth
- N9030B-544 - MPB - Microwave preselector bypass
- N9030B-544 - EP0 - Enhanced phase noise, DDS LO
- N9030B-544 - LNP - Low noise path
- N9030B-544 - EXM - External mixing
- N9030B-544 - FP2 - Fast power; accelerates power measurements such as ACPR
- N9030B-544 - BBA - I/Q baseband inputs, analog; single-ended/differential, 50 Ω/1 MΩ impedance
- N9030B-544 - RT1 - Real-time analysis up to maximum available BW, basic detection
- N9030B-544 - RT2 - Real-time analysis up to maximum available BW, optimum detection
- N9030B-544 - RTR - Real-time spectrum recorder and analyzer application
- N9030B-544 - RTS - Real-time I/Q data streaming
- N9030B-544 - FT1 - Frequency mask trigger, basic detection
- N9030B-544 - FT2 - Frequency mask trigger, optimum detection
- N9030B-544 - EMC - Basic EMI precompliance
- N9030B-544 - EDP - Enhanced display package; includes spectrogram, trace zoom, and zone span
- N9030B-544 - ESC - External source control for Keysight EXG, MXG, and PSG signal generators
- N9030B-544 - SSD - Additional removable solid-state drive
- N9030B-544 - SF1 - Exclude launch program; prevents launching of Windows programs from instrument application
- N9030B-544 - SF2 - Prohibit saving results; prevents saving/recall of measurement results or user configurations
- N9030B-544 - CR3 - Second IF output; wideband IF out
- N9030B-544 - CRP - Arbitrary IF out, 10 to 75 MHz (in 500 kHz steps)
- N9030B-544 - YAV - Y-axis video out; screen video (0-1 volt open circuit)
- N9030B-544 - ALV - Aux log video out; fast rise time video out
- N9030B-544 - UK6 - Commercial calibration certificate with test data
- N9030B-544 - AMG - Keysight Calibration + Uncertainties + Guardbanding (accredited cal)
- N9030B-544 - A6J - ANSI Z540-1-1994 Calibration
| Model | N9030B-544 |
|---|
El Keysight (Agilent) N9030B-544 cubre de 3 Hz a 44 GHz, con ancho de banda en tiempo real de hasta 1 GHz y soporte para mezcla externa en pruebas sub-THz. Ofrece bajo ruido de fase y excelente FM residual.
Compatible con 5G, LTE, radar y satélite, es modular y escalable para proteger la inversión a largo plazo con análisis vectorial completo.
Testwall puede suministrar el Keysight (Agilent) N9030B-544 usado, completamente probado. Con soporte experto y entrega global, Testwall garantiza instrumentos de alto rendimiento con fiabilidad excepcional. Contáctenos si necesita calibración o reparación del Keysight (Agilent) N9030B-544.