The Magna-Power MT Series utilizes the latest IGBT devices to drive down size and increase performance. The high frequency design of the Magna Power MTD600-240 allows fast transient response and low output ripple. This performance coupled with Magna-Power's rugged current-fed power processing, delivers confidence in the most demanding applications.
Working with high-power Power Supplies can inject an element of risk to the user. All Magna-Power MT Series power supplies have extensive diagnostic functions, including: phase loss, excessive thermal conditions, over voltage trip (programmable), over cur trip (programmable), cleared fuse, and excessive program line voltage. When in standby or diagnostic fault, the AC mains are mechanically disconnected via an embedded AC contactor, providing confidence that the unit is only processing power when desired. With the MTD600-240, users are able to work with a high degree of safety.
The Magna-Power MTD600-240 Power Supply comes standard with isolated 37-pin external I/O, RS232, Remote Interface Software, IVI drivers for integration into a variety of programming environment Three front panel types are available for maximum application flexibility. The A Version provides front panel control and calibration, start and stop buttons, and a digital display for voltage and current. The D Version front panel adds a 10-key digital front panel entry, memory sequencing, and modulation capabilities for non-linear output profile emulation.
Specifications of the Magna Power MTD600-240 DC Power Supply include:
Input:
AC Input: 480 Vac, 3Φ (operating range 432 - 528 Vac)
Frequency: 50 Hz (operating range 45 - 55 Hz) 60 Hz (operating range 54 - 66 Hz)
Power Factor: > 92% at maximum power
Output:
Ripple: 250 mVrms
Line Regulation:
Voltage Mode: ± 0.004% of full scale
Cur Mode: ± 0.02% of full scale
Load Regulation
Voltage Mode: ± 0.01% of full scale
Cur Mode: ± 0.04% of full scale
Load Transient Response: 2 ms to recover within ±1% of full scale output, with a 50% to 100% or 100% to 50% step load change
Efficiency: 92% at full load
Stability: ± 0.10% for 8 hrs. after 30 min. warmup
Isolation:
User inputs and outputs: referenced to earth ground
Maximum input voltage to ground: ±2500 Vac
Maximum output voltage to ground: ±1000 Vdc
Maximum Slew Rate: 100 ms for output voltage change from 0 to 63% 100 ms for output cur change from 0 to 63%
With High Slew Rate Option (+HS): 4 ms for output voltage change from 0 to 63% 8 ms for output cur change from 0 to 63%
Bandwidth: 3 Hz for remote analog voltage programming 2 Hz for remote analog cur programming
With High Slew Rate Option (+HS): 60 Hz for remote analog voltage programming 45 Hz for remote analog cur programming
Dimensions: 62.5 x 48 x 31.5 in (158.8 x 121.9 x 80.0 cm)
Weight: 2100 lbs (952.5 kg
Control:
Voltage Programming Accuracy: ± 0.075% of full scale voltage
OVT Programming Accuracy: ± 0.075% of full scale voltage
Cur Programming Accuracy: ± 0.075% of full scale current
OCT Programming Accuracy: ± 0.075% of full scale current
Voltage Readback Accuracy: ± 0.2% of full scale voltage
Cur Readback Accuracy: ± 0.2% of full scale cur External
Analog Programming and Monitoring Levels: 0 - 10 Vdc
Si no estás completamente satisfecho con tu compra, simplemente devuelve el artículo en su estado original dentro de los 30 días posteriores a la recepción.
Los artículos devueltos deben estar sin usar y en su embalaje original, junto con toda la documentación incluida. Emitiremos un reembolso completo al recibir el artículo, excluyendo el coste original del envío. Alternativamente, si lo prefieres, podemos cambiar el artículo.
IVA
Los precios no incluyen IVA.
Transacciones intracomunitarias: Según la Directiva del IVA de la UE, las ventas B2B de bienes dentro de la UE están exentas de IVA.
Cuando se aplica el IVA, se utiliza una tasa del 23%.
Fuera de la UE no se aplica IVA.