Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) N8488A

Thermocouple Power Sensor, 10 MHz - 67 GHz, -35 to +20 dBm
50 MHz - 33 GHz Intervallo di frequenza
-35 dBm a +20 dBm Intervallo di potenza
Sensore di potenza a diodo Tipo di sensore
2,92 mm (maschio) Connettore RF
50 Ohm Impedenza
Richiedi scheda tecnica
Attributo Valore
Intervallo di frequenza 50 MHz - 33 GHz
Intervallo di potenza -35 dBm a +20 dBm
Tipo di sensore Sensore di potenza a diodo
Connettore RF 2,92 mm (maschio)
Impedenza 50 Ohm
Incertezza di calibrazione ±0,9% (tipica)
Tempo di risposta Inferiore a 200 ms
Temperatura operativa 0 °C a +55 °C
Compatibilità Compatibile con misuratori di potenza Keysight serie N1911A/N1912A e EPM
Potenza massima di ingresso +23 dBm (200 mW)
Keysight (Agilent) N8488A Options:
  • N8488A - CFT - SCPI code-compatible to 8480 Series sensors (Note: Option CFT is not available for the N8488A)
  • N8488A - 100 - 1.85 mm (male) connector for N8488A
  • N8488A - 1A7 - ISO 17025 calibration with test data
  • N8488A - A6J - ANSI Z540 calibration with test data
  • N8488A - R-51B-001-3C - Return to Keysight Technologies Warranty - 3 years
  • N8488A - R-51B-001-5C - Warranty Assurance Plan - Return to Keysight Technologies - 5 years
  • N8488A - OB1 - English language Operating and Service Guide
  • N8488A - ABJ - Japanese localization Operating and Service Guide
Modulo di calibrazione Keysight (Agilent) N8488A

Modulo di riparazione Keysight (Agilent) N8488A
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
ModelN8488A

KEYSIGHT N8488A

The Keysight N8488A power sensor has the widest frequency range in Keysight's family of N8480 power sensors. Each of these new sensors allow users to calibrate the power sensor without manually entering the calibration factors in to the power meter. Similar to the rest of N8480 power sensors, the new N8488A power sensors are designed with excellent accuracy, linearity, repeatability, and SWR.

Features and Specifications of the Keysight N8488A (Agilent) Power Sensor include:

  • EEPROM to store cal factors eliminates manual entry
  • Wide frequency range from 10 MHz to 67 GHz (Not warranted spec from 67 to 70 GHz)
  • Wide dynamic range from -35 to +20 dBm
  • Best-in-class power linearity of less than 1%, excellent SWR of mismatch uncertainty and highly accurate power repeatability
  • Accurate calibration and traceability to US National Institute of Standards and Technology (NIST)
  • SCPI codes compatibility
  • Compatible with EPM (new N1913/14A, E4418/19B), EPM-P (E4416/17A), P-Series (N1911/12A) power meters  

 