Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) 8902A

Measuring Receiver
100 kHz to 1.3 GHz Frequency Range
Measuring Receiver (AM/FM Demodulation, RF Level, Sinad, Distortion, Frequency) Measurement Function
50 Ohms Input Impedance
-127 dBm to +30 dBm RF Level Measurement Range
Up to ±150 kHz FM Deviation Measurement Range
Request datasheet
Attribute Value
Frequency Range 100 kHz to 1.3 GHz
Measurement Function Measuring Receiver (AM/FM Demodulation, RF Level, Sinad, Distortion, Frequency)
Input Impedance 50 Ohms
RF Level Measurement Range -127 dBm to +30 dBm
FM Deviation Measurement Range Up to ±150 kHz
AM Modulation Measurement Range 0% to 99.9% AM Depth
Audio Frequency Range 50 Hz to 15 kHz
SINAD / Distortion Measurement SINAD range: 0 to 60 dB; THD range: 0.03% to 100%
Interface / Bus HP-IB (IEEE-488 / GPIB)
Power Requirements 100/120/220/240 VAC, 48–66 Hz, approximately 175 VA
Keysight (Agilent) 8902A Options:
  • 8902A - 002 - High stability time base (1x10⁻⁹/day aging rate internal reference)
  • 8902A - 003 - LO Input (50 Ω impedance, ~1.27 MHz to 1301.5 MHz, 0 dBm nominal)
  • 8902A - 030 - Carrier Noise measurement option
  • 8902A - 031 - Carrier Noise measurement option
  • 8902A - 032 - Carrier Noise measurement option
  • 8902A - 033 - Carrier Noise measurement option
  • 8902A - 034 - Carrier Noise measurement option
  • 8902A - 035 - Carrier Noise measurement option
  • 8902A - 036 - Carrier Noise measurement option
  • 8902A - 037 - Carrier Noise measurement option
  • 8902A - 050 - Increased power measurement accuracy; Tuned RF Level accuracy of ±(0.015 dB + 0.005 dB/10 dB step), operating range 2.5 MHz to 26.5 GHz, operating temperature 15°C to 30°C
Calibration Form Keysight (Agilent) 8902A

Repair Form Keysight (Agilent) 8902A
Maximum file size: 40MB

No Related Posts

More Information
Model8902A

The Keysight (Agilent) 8902A Measuring Receiver offers precision like a high-performance power meter, covering frequencies from 150 kHz to 1.3 GHz, extendable to 26.5 GHz using the 11793A converter. It handles power levels from +30 dBm to -127 dBm, supporting AM, FM, and phi-M signal analysis with advanced noise and distortion measurement features.

Engineered for RF and audio applications, the 8902A supports fast frequency counting, 1 Hz resolution, and advanced accuracy with Option 050. It’s ideal for residual, incidental, and carrier noise testing with excellent long-term frequency stability.

Testwall can supply the used Keysight (Agilent) 8902A, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Keysight (Agilent) 8902A.

Clicky Copyright © 2025-present Magento, Inc. All rights reserved.