Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) 4286A

1mHz-1GHz LCR Meter
1 MHz to 1 GHz Frequency Range
|Z|, |Y|, θ, R, X, G, B, Cs, Cp, Ls, Lp, Rs, Rp, D, Q, Δ%, and equivalent circuit analysis Measurement Parameters
±0.8% Basic Impedance Accuracy
1 mΩ to 100 MΩ Impedance Measurement Range
10 mV to 1 V RMS (oscillator output) Test Signal Level (Voltage)
Request datasheet
Attribute Value
Frequency Range 1 MHz to 1 GHz
Measurement Parameters |Z|, |Y|, θ, R, X, G, B, Cs, Cp, Ls, Lp, Rs, Rp, D, Q, Δ%, and equivalent circuit analysis
Basic Impedance Accuracy ±0.8%
Impedance Measurement Range 1 mΩ to 100 MΩ
Test Signal Level (Voltage) 10 mV to 1 V RMS (oscillator output)
DC Bias 0 to ±40 V internal DC bias capability
Measurement Speed Fast, Medium, and Slow measurement modes available
Interface/Connectivity HP-IB (GPIB) interface for remote control and automation
Display Built-in CRT display for impedance vs. frequency sweep results
Power Requirements 100/120/220/240 VAC, 48 to 66 Hz, approximately 200 VA
Keysight Technologies 4286A Options:
  • 4286A - Opt 021 - Add Straight Angle Test Head (1 m)
  • 4286A - Opt 022 - Add Straight Angle Test Head (3 m)
  • 4286A - Opt 031 - Delete Right Angle Test Head (1 m)
  • 4286A - Opt 032 - Add Right Angle Test Head (3 m)
  • 4286A - Opt 001 - Delete HP 16195A Cal Kit
  • 4286A - Opt 002 - Delete Test Fixture Stand
  • 4286A - Opt 004 - Add Working Standard Set
  • 4286A - Opt 1C2 - Add HP-iBASIC, Keyboard, Cable
Calibration Form Keysight (Agilent) 4286A

Repair Form Keysight (Agilent) 4286A
Maximum file size: 40MB

No Related Posts

More Information
Model4286A
The Keysight (Agilent) 4286A RF LCR Meter delivers high-accuracy impedance measurements in the RF range, using a direct-current voltage-measurement technique instead of conventional reflection methods. Operating at 1 MHz to 1 GHz, it offers precise impedance evaluation over a wide range and advanced calibration for improved Q measurement accuracy—typically 6% at 100 MHz with Q=100. This capability minimizes design uncertainty by providing true device values under RF conditions. Configurable with various test heads, calibration, and standard sets, it supports flexible testing setups. Ideal for electronic component evaluation, circuit analysis, and RF material testing, the 4286A enhances design confidence and quality control. Testwall can supply the used Keysight (Agilent) 4286A, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Keysight (Agilent) 4286A.