Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) E8241A

250KHz-20GHz Microwave Signal Generator
250 kHz to 20 GHz Frequency Range
FM, ΦM Modulation
0.01 Hz Frequency Resolution
< 15 ms (typ.) Switching Speed
step sweep, list mode Sweep Modes
Request datasheet
Attribute Value
Frequency Range 250 kHz to 20 GHz
Modulation FM, ΦM
Frequency Resolution 0.01 Hz
Switching Speed < 15 ms (typ.)
Sweep Modes step sweep, list mode
Output Power -20 to +13 dBm (depending on configuration)
SSB Phase Noise -130 dBc/Hz at 1 GHz, 20 kHz offset (spec.)
Level Accuracy ±0.6 dB at 250 kHz to 2 GHz, ±0.8 dB at 2 to 20 GHz (spec.)
Harmonics < -55 dBc at 2 to 20 GHz (spec.)
Non-Harmonics < -80 dBc at 250 MHz to 1 GHz, > 3 kHz offset (spec.)
Timebase Aging 10 MHz, ±1 × 10⁻⁷ per year
RF Output Connector 3.5 mm male or Type-N
Interfaces GPIB, LAN, RS-232
Dimensions 426 × 178 × 498 mm
Weight < 22 kg
Keysight Technologies E8241A Options:
  • E8241A - 1EA - High output power (+20 dBm at 20 GHz)
  • E8241A - 1E1 - Step attenuator (wide output power range to –135 dBm)
  • E8241A - UNJ - Improved close to carrier phase noise (extends improved performance to less than 1 kHz offset)
  • E8241A - W50 - Extended five year warranty
Calibration Form Keysight (Agilent) E8241A

Repair Form Keysight (Agilent) E8241A
Maximum file size: 40MB

The Keysight (Agilent) E8241A Signal Generator offers a frequency range of 250 kHz to 20 GHz with 0.01 Hz resolution and delivers up to +20 dBm at 20 GHz. It ensures precise performance with level accuracy of ±0.7 dB and low phase noise of -110 dBc/Hz at 20 kHz offset. Enhanced noise performance is available with Option UNJ, improving offset at 1 kHz to -98 dBc/Hz.

Ideal for high-power device testing, it eliminates external amplifiers and supports digital sweep modes with user flatness correction. Compatible with frequency extension to 110 GHz.

Testwall can supply the used Keysight (Agilent) E8241A, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Keysight (Agilent) E8241A.

Options and configurations

  • Output Power: -20 to +13 dBm (up to +20 dBm with Opt. 1EA); -135 dBm with Opt. 1E1
  • Timebase Aging: 10 MHz, ±1 × 10⁻⁷ per year (±3 × 10⁻⁸ with Opt. UNJ)
  • RF Output Connector: 3.5 mm male or Type-N (Opt. 1ED)
Clicky
Copyright © 2025-present Magento, Inc. All rights reserved.