Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) N5193A

Option 540 (10 MHz to 40 GHz) – UXG Agile Signal Generator, 2.4 mm (m)
10 MHz to 40 GHz Frequency Range
±1.4 dB (typ.), ALC on Level Accuracy
10 kHz Frequency Resolution
-55 dBc above 2 GHz Harmonics
-70 dBc (typ.) Non-Harmonics
Request datasheet
Attribute Value
Frequency Range 10 MHz to 40 GHz
Level Accuracy ±1.4 dB (typ.), ALC on
Frequency Resolution 10 kHz
Harmonics -55 dBc above 2 GHz
Non-Harmonics -70 dBc (typ.)
Output Power -10 to +10 dBm (standard); +7 dBm at 25.6 to 40 GHz
SSB Phase Noise -114 dBc/Hz at 10 GHz, 20 kHz offset (spec.)
Modulation AM, FM, ΦM, pulse, chirp (depending on configuration)
Switching Speed 95 µs
Sweep Modes list mode
Timebase Aging ±3 × 10⁻⁸ per year
RF Output Connector 3.5 mm male (depending on configuration)
Interfaces GPIB, LAN, USB
Dimensions 426 × 134 × 559 mm
Weight 25 kg (max.)

Available configurations

ModelFrequency rangeConfiguration
N5193A-52010 MHz to 20 GHzAgile signal generator
N5193A-54010 MHz to 40 GHzAgile signal generator
Calibration Form Keysight (Agilent) N5193A

Repair Form Keysight (Agilent) N5193A
Maximum file size: 40MB

The Keysight (Agilent) N5193A-540 offers wide frequency coverage from 100 kHz to 40 GHz, featuring low phase noise of –107 dBc/Hz at 3 GHz and 20 kHz offset, and an output power range from –20 to +11 dBm, with a +18 dBm option. It supports advanced analog modulation formats including AM, FM, PM, and pulse train capabilities, and ensures rapid settling of ~5 ms with optional UNZ. Connectivity includes LAN, USB, and GPIB, fully LXI-compliant.

This model is ideal for sophisticated microwave testing environments, offering full modulation support for complex signal simulations and performance-critical designs.

Testwall can supply the used Keysight (Agilent) N5193A-540, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Keysight (Agilent) N5193A-540.

Options and configurations

  • Frequency Range: 10 MHz to 40 GHz (Opt. 540)
  • Frequency Resolution: 10 kHz; 0.001 Hz with Opt. FR1
  • Output Power: -10 to +10 dBm (standard); -130 dBm with Opt. AT2; +7 dBm at 25.6 to 40 GHz
  • SSB Phase Noise: -114 dBc/Hz at 10 GHz, 20 kHz offset (spec.); -121 dBc/Hz at 10 kHz offset with Opt. EP1
  • Modulation: AM, FM, ΦM (Opt. UNT), pulse (Opt. PM1), chirp
  • Switching Speed: 95 µs; 180 ns with Opt. SS4
  • RF Output Connector: 3.5 mm male (Opt. 520), 2.4 mm male (Opt. 540); Type-N female with Opt. 1ED
Clicky