Pacific Power 3240AFX-2A

| Attribute | Value |
|---|---|
| Output Power | 3240 VA |
| Number of Phases | 2 |
| Output Voltage Range | 0 to 300 VAC per phase |
| Output Frequency Range | 45 Hz to 500 Hz |
| Total Harmonic Distortion (THD) | Less than 0.5% at full linear load |
| Input Voltage | 208/240 VAC, Single or Three Phase |
| Input Frequency | 47 Hz to 63 Hz |
| Programmable Waveform | Arbitrary waveform synthesis with up to 50 harmonics |
| Control Interface | IEEE-488 (GPIB) and RS-232 programmable interface |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
Pacific Power 3240AFX-2A Options:
- 3240AFX-2A - T - High Voltage Output Transformer Option (400V Range): adds AC-only mode range supporting 0-400 VL-N / 0-692 VL-L (Three Phase)
- 3240AFX-2A - G - GPIB Interface Option (IEEE488.1, IEEE488.2)
- 3240AFX-2A - O - Output Control Switch Option
- 3240AFX-2A - A - Analog and Digital Auxiliary I/O
- 3240AFX-2A - E - Export Version
- 3240AFX-2A - RS - 19" Rack Slides Accessory
- 3240AFX-2A - PPSC Studio - Windows 10 64-Bit PPSC Studio Control Software
- 3240AFX-2A - PPSC Test Manager - Windows 10 64-Bit PPSC Test Manager Software
- 3240AFX-2A - ABD0100.1.8 - Test Sequence: Airbus A380, AC & DC Power Groups
- 3240AFX-2A - ABD0100.1.8.1 - Test Sequence: Airbus A350, AC & DC Power Groups
- 3240AFX-2A - AMD24C - Test Sequence: Airbus A400M, AC & DC Power Groups
- 3240AFX-2A - Boeing787B3-0147 - Test Sequence: Boeing 787, AC & DC Power Groups
- 3240AFX-2A - MIL-STD704 - Test Sequence: US DoD, AC & DC Power Groups
- 3240AFX-2A - RTCA-DO160 - Test Sequence: Section B, AC & DC Power Groups
- 3240AFX-2A - IEC Test Suite - Test Sequence: IEC 61000-4-11, -4-14, -4-27, -4-28, -4-29p and -4-34
- 3240AFX-2A - MIL-STD1399-300B - Test Sequence: US DoD Shipboard Power, AC Power Groups
| Model | 3240AFX-2A |
|---|
The Pacific Power 3240AFX 2A AC/DC Power Source delivers advanced digital power conversion with unmatched power density. Engineered for avionics, radar, and weapons systems, it offers precise control over voltage, current, frequency, phase angles, and transients. Its dual AC/DC operating modes support both types of equipment, with a voltage range up to 425Vdc and flexible output configurations including bipolar DC.
Equipped with a built-in web server and digital scope, the 3240AFX 2A ensures easy browser-based control and synchronized waveform capture. Operators benefit from accurate phase relationships, high flexibility, and simplified test program execution.
Testwall can supply the used Pacific Power 3240AFX 2A, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Pacific Power 3240AFX 2A.