Teseq (Schaffner)

Schaffner NSG 203A

Line Voltage Variation Simulator
0 to 4400 V peak Output Voltage Range
Up to 200 A peak Output Current
5 ns typical Pulse Rise Time
50 ns to 1 ms Pulse Duration
Up to 1 MHz Repetition Rate
Request datasheet
Attribute Value
Output Voltage Range 0 to 4400 V peak
Output Current Up to 200 A peak
Pulse Rise Time 5 ns typical
Pulse Duration 50 ns to 1 ms
Repetition Rate Up to 1 MHz
Output Impedance 50 Ω
Compliance Standards IEC 61000-4-4 (EFT/Burst), IEC 61000-4-5 (Surge)
Power Supply Input 100–240 V AC, 50/60 Hz
Operating Temperature 0°C to 40°C
Interface / Control RS-232 / IEEE-488 (GPIB) remote control interface
Calibration Form Schaffner NSG 203A

Repair Form Schaffner NSG 203A
Maximum file size: 40MB

No Related Posts

More Information
ModelNSG 203A

The Keysight (Agilent) Teseq Schaffner NSG203A plug‑in module is engineered to precisely simulate short‑term line voltage variations and complete failures. When shifting from a high voltage (e.g. 150 V) to an abnormally low level (e.g. 280 V on the opposite line), it integrates seamlessly with external variable voltage transformers using NSG 322 or NSG 323 connectors.

This robust simulator meets rigorous test standards including Mil‑Std‑704 A, Mil‑Std‑E 4158 (Table II – Fig. 1), BS 4509/4525, CEE (Sekr. 229), UK 121, EEC Com. (78) 766 final, VDE 0160 8, and CE GB – EES (1970).

Testwall can supply the used Keysight (Agilent) Teseq Schaffner NSG203A, fully tested. With expert support and global delivery, Testwall ensures high‑performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Keysight (Agilent) Teseq Schaffner NSG203A.

Clicky Copyright © 2025-present Magento, Inc. All rights reserved.