Ceyear

Ceyear 3672A-S

10MHz - 3.5GHz Network Analyser

10 MHz to 26.5 GHz Frequency Range
-110 dBm to +20 dBm Output Power Range
0.001 Hz Frequency Resolution
≤ -115 dBc/Hz @ 10 GHz, 10 kHz offset SSB Phase Noise
≤ -30 dBc Harmonic Suppression
Request datasheet
Attribute Value
Frequency Range 10 MHz to 26.5 GHz
Output Power Range -110 dBm to +20 dBm
Frequency Resolution 0.001 Hz
SSB Phase Noise ≤ -115 dBc/Hz @ 10 GHz, 10 kHz offset
Harmonic Suppression ≤ -30 dBc
Non-Harmonic Spurious ≤ -60 dBc
Amplitude Accuracy ±1.0 dB
Modulation Types AM, FM, PM, Pulse Modulation
RF Connector 2.92 mm (K-type) female
Interface USB, LAN (LXI), GPIB
Ceyear 3672A-S Options:
  • 3672A-S - 201 - 2-Port Programmable Step Attenuator: Set two 70dB programmable step attenuators for the source path, and two 35dB programmable step attenuators for the receiver path
  • 3672A-S - 400 - 4-Port Measurement: Two-source stimulus four-port VNA configuration
  • 3672A-S - 401 - 4-Port Programmable Step Attenuator: Set four 70dB programmable step attenuators for the source path, and four 35dB programmable step attenuators for the receiver path (Option 400 is needed)
  • 3672A-S - 402 - Active Inter-modulation Measurement: For inter-modulation signal measurement of amplifier (Option 400 is needed)
  • 3672A-S - 006 - English Options: Key, Front Panel, Label, Operation System
  • 3672A-S - 008 - Pulse Measurement: For pulse S-parameter measurement
  • 3672A-S - S10 - Time Domain Measurement: For time-domain test, can locate and analyze the discontinuous positions in devices, fixtures or cables
  • 3672A-S - S80 - Frequency Offset Measurement: For frequency offset measurement; millimeter-wave frequency extension main unit needs this option
  • 3672A-S - S82 - Mixer Scalar Measurement: For the scalar parameter measurement of mixers (Option 400 is needed)
  • 3672A-S - S83 - Mixer Vector Measurement: For the vector parameter measurement of mixers (Option 400 is needed)
  • 3672A-S - S84 - Embedded LO Frequency Converter Measurement: For the measurement of embedded LO frequency converters (Option 400, S82 or S83 are needed)
  • 3672A-S - S86 - Gain Compression Two-Dimension Sweep Measurement: For the gain compression two-dimension sweep test of amplifier
Calibration Form Ceyear 3672A-S

Repair Form Ceyear 3672A-S
Maximum file size: 40MB

No Related Posts

More Information
Model3672A-S

The Ceyear 3672A-S is a high-performance vector network analyzer designed to deliver fast sweep speed, wide dynamic range, and versatile measurement capabilities. It supports multiple calibration types including frequency response, single port, response isolation, enhanced response, full dual-port, and E-calibration. The instrument offers display formats such as logarithmic amplitude, linear amplitude, standing-wave ratio, phase, group delay, Smith chart, and polar coordinates. Equipped with USB, LAN, GPIB, and VGA interfaces, it ensures seamless connectivity. The 12.1-inch (30.7 cm) high-resolution touch screen enhances usability, while record/run one-click operation simplifies measurement steps and boosts efficiency.

Engineered for precision, the Ceyear 3672A-S supports multi-window and multi-channel tests, allowing users to execute complex test schemes efficiently. It is ideal for analyzing amplitude-frequency, phase-frequency, and group delay characteristics with high accuracy.

Testwall can supply the used Ceyear 3672A-S, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Ceyear 3672A-S.